6. Secure ventilation hood while tightening the 4 brackets / clips.
Electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards and the unit must be grounded.
7. Electrical Connection
• Run three wires, two for the power supply and
one for the ground wire, from the power
connection box on the ventilation hood to a
power connection point near the installation.
• Open the power connection box on the
ventilation hood and secure the power conductor
with a cULus listed strain relief (not included).
• Connect the power conductors to the conductors
for the ventilation hood, black to black and white
to white.
• Connect the grounding wire (green or bare) to
the ground conductor (green) of the ventilation
hood power connection box.
• Secure all the connections with cULus listed wire
nuts.
• Replace the power connection box cover.
Updated: Thu, 02 Apr 2020 06:40:38 GMT
Powered by
10