1
4
INSTALLATION INSTRUCTIONS
WARNING!
Electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards and the unit must be grounded.
7
Electrical connection
●
●
Run three wires, two for the power supply and one for the ground wire, from the
power connection box on the ventilation hood to a power connection point near
the installation.
●
●
Open the power connection box on the ventilation hood and secure the power
conductor with a cULus listed strain relief (not included).
●
●
Connect the power conductors to the conductors for the ventilation hood, black to
black and white to white.
●
●
Connect the grounding wire (green or bare) to the ground conductor (green) of the
ventilation hood power connection box.
●
●
Secure all the connections with cULus listed wire nuts.
●
●
Replace the power connection box cover.
EN
Gray
4 speed
Black
3 speed
Red
2 speed
Blue
1 speed
Brown
(neutral)