background image

8

Customer care

Check the things you can do yourself.  
Refer to your User Guide and check:

  Your appliance is correctly installed.

2

   You are familiar with its normal operation.

If after checking these points you still need assistance, please refer to your nearest  
AUTHORISED SERVICE CENTRE, or contact us through our local website listed on the back cover.

In New Zealand if you need assistance...*

Call your Fisher & Paykel retailer who is trained to provide information on your appliance, or if we 
can be of any further help, please contact our Customer Care Centre,

Toll Free:

 0800 FP CARE or 0800 37 22 73  

Fax:

 (09) 273 0656

Email:

 [email protected] 

Postal address:

 P.O. Box 58732, Greenmount, Auckland

If you need service...*

Fisher & Paykel has a network of independent Fisher & Paykel Authorised Service Centres whose 
fully trained technicians can carry out any service necessary on your appliance. Your dealer or 
our Customer Care Centre can recommend an Authorised Service Centre in your area.

In Australia if you need assistance...*

Call the Fisher & Paykel Customer Care Centre and talk to one of our Customer Care Consultants.

Toll Free:

 13 00 650 590  

Fax:

 (07) 3826 9298

Email:

 [email protected] 

Postal Address:

 PO Box 798, Cleveland QLD 4163

If you need service...*

Fisher & Paykel Australia Pty Ltd has a network of independent Fisher & Paykel Authorised 
Service Centres whose fully trained technicians can carry out any service necessary on your 
appliance. Our Customer Care Centre can recommend an Authorised Service Centre in your area.

In United Kingdom if you need assistance...*

Phone:

 (0845) 066 2200

Fax:

 (0845) 331 2360

Email:

 [email protected]

Postal Address:

 Fisher & Paykel Appliances Limited, Maidstone Road, Kingston,  

Milton Keynes, Buckinghamshire, MK10 0BD

In Ireland if you need assistance...*

Phone:

 01800 625 174

Fax:

 01800 635 012

Email:

 [email protected]

Postal Address:

 Fisher & Paykel Appliances (Irl) Ltd, Unit D2, North Dublin Corporate Park, 

Swords, Co Dublin

Содержание HI120DMB1

Страница 1: ...Designer series island canopy NZ AU GB IE HI120DXB1 HI120DMB1 models Installation instructions and User guide ...

Страница 2: ...r care 8 Contents Important SAVETHESEINSTRUCTIONS The models shown in this User Guide may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please visit our local website listed on the back cover or contact your local Fisher Paykel dealer ...

Страница 3: ...ower off prior to installation servicing or cleaning the island canopy Never use the island canopy without the filters in place Stainless steel is very easily damaged during installation if abraded or knocked by tools It is recommended to protect the top of the canopy with cardboard or polystyrene during the installation to minimise the risk of damage occurring A power outlet should be within 750 ...

Страница 4: ...ts 1 x installation instructions 4 x aluminium mesh filters 4 x 12 x 40 mm screw 30 x 6 x self tapping screw 2 spare Typical equipment required Electric drill Screwdriver Duct tape Jig saw Ladder Ducting Tape measure Drill bits Spirit level Accessories Accessory Part Number Chimney ext 3048 mm 10 ceiling SS 89094 Chimney ext 3048 mm 10 IR 89095 Recirculation kit RR1744 Replacement charcoal filter ...

Страница 5: ...will require a 160 mm min round hole in the ceiling which the decorative chimney will cover Care should be taken to align the canopy with the decorative chimney allowing sufficient clearance to accommodate the ducting For optimum efficiency use smooth wall solid galvanized or plastic ducting for reduced noise and increased airflow Flexible ducting should only be used as a last resort ie in difficu...

Страница 6: ... the ceiling and into the truss b If securing to any other ceiling type please use appropriate fasteners and follow their instructions of use carefully 5 For the ducting mark out and cut a Ø160 mm min hole in the ceiling 6 Fix the ceiling bracket to the ceiling using the screws supplied 7 Using duct tape secure the ducting to the top of the motor housing Tape the power plug to the top of the ducti...

Страница 7: ...cure it so that the upper chimney is showing Duct tape or placing two screws nails through the upper chimney securing holes will do this 11 Offer the island canopy angle brackets chimneys and ducting up to the ceiling bracket and secure in place with eight screws provided one per side per corner The dimension between the filters and the cooking surface should be in line with those suggested in the...

Страница 8: ...ing vapours prior to the cleansed air re entering the kitchen when the island canopy is in recirculating mode Charcoal filters are disposable items and it is recommended that these should be replaced every three to six months depending on use Note Fully saturated charcoal filters can become a barrier to air movement impeding the island canopy s performance In the event of fire fully grease laden f...

Страница 9: ...ther than 1 Normal domestic use or 2 Use in accordance with the Product s User Guide C Defects to the Product caused by accident neglect misuse or Act of God D The cost of repairs carried out by non authorised repairers or the cost of correcting such unauthorised repairs E Normal recommended maintenance as set out in the Product s User Guide F Repairs when the appliance has been dismantled repaire...

Страница 10: ...iance Your dealer or our Customer Care Centre can recommend an Authorised Service Centre in your area In Australia if you need assistance Call the Fisher Paykel Customer Care Centre and talk to one of our Customer Care Consultants Toll Free 13 00 650 590 Fax 07 3826 9298 Email customer care fp com au Postal Address PO Box 798 Cleveland QLD 4163 If you need service Fisher Paykel Australia Pty Ltd h...

Страница 11: ... number serial number date of purchase and a description of the problem This information is needed in order to better respond to your request for assistance Product Details Fisher Paykel Appliances Ltd Model Serial No Date of Purchase Purchaser Dealer Suburb Town Country ...

Страница 12: ...ntinuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available www fisherpaykel co nz www fp com au www fisherpaykel co uk www fisherpaykel ie NZ AU GB IE Designer series island canopy Installation instructions and user guide Published 02 2009 Part No 400006 E ...

Отзывы: