background image

3

SAFETY AND WARNINGS

!

  WARNING!

4.8 kg

(HF60)

Weight Hazard

The rangehood is heavy. Please ensure adequate care is taken when 

installing the rangehood to prevent personal injury. The rangehood must 

be installed onto a solid wall, stud, beam or truss. Weight of the HF60 

is 4.8 kg. 

!

  WARNING!

Electric Shock Hazard

Always disconnect the appliance from the mains power supply before 

carrying out any maintenance or repairs. Alterations to the domestic 

wiring system must be made by a qualified electrician. 

Failure to follow this advice may result in electric shock or death. 

IMPORTANT SAFETY INSTRUCTIONS

WARNING! When using this appliance always exercise basic safety precautions including 

the following:

Please read the entire set of instructions before installing or using this appliance.

Please make this information available to the person installing the appliance –  

doing so could reduce your installation costs. 

Always switch the power off prior to installation, servicing or cleaning 

of the rangehood.

This appliance must be installed and connected to the mains power supply only by a 

suitably qualified person according to these installation instructions and in compliance 

with any applicable local building and electricity regulations. Failure to install the 

appliance correctly could invalidate any warranty or liability claims.

To comply with electrical safety regulations, the rangehood must be plugged into 

a socket near the appliance. The socket must be accessible, or have an accessible 

isolating switch, to enable the end user to isolate the rangehood from the power for 

the purpose of internal cleaning or maintenance. 

A power outlet should be within 750 mm of the motor assembly and can either be on 

the wall, behind the chimney or in the ceiling. 

If the supply cord of this equipment is damaged, it must only be replaced by the 

manufacturer, its service agent or similarly qualified person in order to avoid a hazard. 

Ducting accessories are not supplied. All ducting must comply with local requirements 

and building codes.

Attention should be given to ensure that any applicable regulations concerning the 

discharge of exhaust air are fulfilled. 

Before connecting any pipes, consult municipal ordinances to ensure that any 

applicable regulations concerning the discharge of exhaust air are adhered to and 

request permission from the person in charge of the building.

Exhaust air must not be discharged into an existing flue that is used for exhausting 

fumes from appliances burning gas or other fuels. 

Содержание HF60LW4

Страница 1: ...Standard Rangehood HF60LX4 and HF60LW4 model NZ AU INSTALLATION INSTRUCTIONS USER GUIDE ...

Страница 2: ......

Страница 3: ...s shown in this user guide may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please go to our website www fisherpaykel com or contact your local Fisher Paykel dealer Registration Register your product with us so we can provide you with the best service possible To register your product visit our ...

Страница 4: ......

Страница 5: ...and in compliance with any applicable local building and electricity regulations Failure to install the appliance correctly could invalidate any warranty or liability claims To comply with electrical safety regulations the rangehood must be plugged into a socket near the appliance The socket must be accessible or have an accessible isolating switch to enable the end user to isolate the rangehood f...

Страница 6: ...ed physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Cleaning and user maintenance shall not be made by children without supervision You must read the details concern...

Страница 7: ...ntents of packaging 10 mm self tapping screw 2 Installation instructions User guide manual 1 125 mm diameter ducting adapter 1 Duct hole cover 1 Rangehood 1 Standard Rangehood HF60LX4 model NZ AU INSTALLATION INSTRUCTIONS USER GUIDE ...

Страница 8: ...duct 75 E Distance from centre of ducting outlet to side of product 298 F Diameter of ducting outlet 125 G Length of light 385 H Width of light 55 I Distance between back of light to back of product 13 J Depth of top surface of product 340 Length of power cord 900 IMPORTANT Actual product dimensions may vary by 2 mm Please read the entire instructions before installing the rangehood A b d g H c Po...

Страница 9: ...ooktop Gas cooktop min 600 max 750 min 650 max 750 Rangehood installation height above the cooktop is the user s preference Lower installation heights will improve the efficiency of capturing cooking odours grease and smoke This rangehood must be installed between the minimum and maximum dimensions indicated in the table above K ...

Страница 10: ...possible and use rigid or semi rigid ducting for reduced noise and increased airflow Flexible metal ducting should only be used as a last resort ie in difficult installations and if used ensure that it is straight and smooth and extended as much as possible Recirculating To enable the product to operate with the air recirculating ensure the lever on the motor casing under the filter is in the reci...

Страница 11: ...the voltage V and the frequency Hz indicated on the serial plate match the voltage and frequency at the installation site Check that all functions are working Check that the area behind the installation surface to be drilled is clear of any electrical cables or pipes etc The rangehood surfaces can be damaged during installation if grazed or knocked by tools Please take care to protect the surfaces...

Страница 12: ...pansion plugs if attaching to masonry Ensure that there is a 2 mm gap between the screw head and the wall see Fig 3 INSTALLATION INSTRUCTIONS PRODUCT DIMENSIONS mm L Rangehood attachment point width 540 M Lower rangehood attachment point height 35 N Upper rangehood attachment point height 103 Fig 4 Upper rangehood attachment points Lower rangehood attachment points L N M Fig 3 2 mm ...

Страница 13: ... the supports see Fig 5 Hang the rangehood off the upper rangehood mounting screws with 2 mm gap Hang off the keyhole attachment points on the back of the rangehood see Fig 6 then tighten the screws Attach the lower rangehood mounting screws to fix the rangehood to the wall Refit the filter 3 Remove packaging Remove all packaging and protective wrappings Fig 5 Fig 6 ...

Страница 14: ...10 Attach the rangehood to the cupboard using the mounting holes refer to Fig 8 below Create additional means of attachment using the extra holes found on top panel of the rangehood Ensure all fixings are secure Refit the filter PRODUCT DIMENSIONS mm O Rangehood attachment point width 540 P Rangehood rear attachment point 30 Q Rangehood front attachment point 301 Q O P Fig 7 3 Attach ducting if du...

Страница 15: ...IONS Control panel Note we recommend turning your rangehood on before you start cooking for optimal performance Extractor fan operating control pilot light Lighting on and off Extractor fan off Extractor fan speed 1 2 and 3 ...

Страница 16: ...ve which can cause damage to your rangehood Note in areas of high humidity or coastal environments cleaning should be carried out more frequently Aluminium filters Depending on use and at least once a month the aluminium grease filter should be removed and cleaned with hot soapy water or in a dishwasher If washed in a dishwasher the filter should be placed in an upright position to prevent food fr...

Страница 17: ...ctive carbon filters are disposable items designed to remove grease and odours from cooking vapours before the air is channelled back into the kitchen The active carbon filters must be replaced periodically to work properly at least every three months depending on the frequency with which the rangehood is used Note fully saturated carbon filters can become a barrier to air movement therefore limit...

Страница 18: ...16 PARTS AND ACCESSORIES ITEM REFERENCE NUMBER Light bulb 792507 Aluminium filter 792512 Recirculation carbon filter 792506 Ducting kit 125 mm eaves PD RHK125E Ducting kit 125 mm wall PD RHK125W ...

Страница 19: ... use or 2 Use in accordance with the product s user guide C Defects to the product caused by accident neglect misuse or act of God D The cost of repairs carried out by non trained and supported service technicians or the cost of correcting such repairs E Normal recommended maintenance as set out in the product s user guide F Repairs when the appliance has been dismantled repaired or serviced by ot...

Страница 20: ...t be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Please keep this user guide in a safe place ...

Страница 21: ...ice necessary on your appliance Our Customer Care Centre can recommend a Fisher Paykel trained and supported service technician in your area In Australia if you need assistance Call the Fisher Paykel Customer Care Centre and talk to one of our Customer Care Consultants Toll Free 1300 650 590 Fax 07 3826 9298 Website www fisherpaykel com Postal address Fisher Paykel Appliances Australia Pty Ltd PO ...

Страница 22: ...20 CUSTOMER CARE Complete and keep for safe reference Model Serial No Purchase Date Purchaser Dealer Suburb Town Country ...

Страница 23: ......

Страница 24: ... booklet apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available NZ AU ...

Отзывы: