Fisher & Paykel DishDrawer DD60ST Series Скачать руководство пользователя страница 3

PARTS SUPPLIED

If the Drain hose supplied is not long enough to reach your services, you 

must

 use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose by 3.6m. The kit is available from the nearest Fisher & Paykel 

Authorised Service Centre or our local website listed at the end of this document. 

4

5 CAVITY PREPARATION

 

These marks indicate formed bracket screw locations.

 
 

Preferred position. If adequate clearance, services hole can be higher.

 

If hole is higher, ensure drain hose is routed straight into the waste connection.

 

Water Connection

 Recommended 

COLD

 (Maximum 60°C).

 

¾

   “ BSP (GB20) to suit flat washer.

 

Water Pressure 

 

 

Max

 

 

 

Min

 

Water softener models  

1 MPa (145 psi)   

0.1 MPa (14.5 psi)

 

Other models  

 

1 MPa (145 psi)   

0.03 MPa (4.3 psi)

 

Drains will need to be separated to satisfy kosher requirements. 

 

We suggest you confirm acceptability with your local rabbi in 

 

respect to kosher installations.

*

Clamp (1)

Wire clip (1)

Phillips 

16 mm 

screws (7)

38 mm

bottom 

fixing screws 

& metal 

washers (2)

Drain hose 

support (1)

Moisture protection 

tape (1)

(to prevent moisture 

damage) 

Cavity bracket 

kit (1)

Drain hose 

joiner (1)

Rubber 

washer for 

inlet hose (1)

Side mounting

bracket kit

(A and B)

 (2)

OPTIONAL

Top mounting

brackets (2)

OPTIONAL

Note: Se

rvices can be locat

ed 

either side of DishDra

wer®.

Important!

Adjacent cabinetry must not
extend above cavity base

220-240 VAC
min. 4.5 A

min. 

200 mm

10 mm

max. 

450 mm

min. ø 

60 mm

Moisture 

protection

tape must 

be applied.

*

*

Water supply

(2,1)  -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM

(2,1)  -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM

Содержание DishDrawer DD60ST Series

Страница 1: ...e to use caution could result in injury or cuts Importantsafetyinstructions Installation of this DishDrawer requires basic mechanical and electrical skills Be sure to leave these Instructions with the...

Страница 2: ...racketslots 2 Inthisinstance youwouldskipstep 6 3 Includescavitybracket 4 Panelthickness 18mm Note for Prefinished Flat door models the height from the top of handle to the top of door 64 mm I Install...

Страница 3: ...a 14 5 psi Other models 1 MPa 145 psi 0 03 MPa 4 3 psi Drains will need to be separated to satisfy kosher requirements We suggest you confirm acceptability with your local rabbi in respect to kosher i...

Страница 4: ...Right hand side Drain hose 2000 mm 1800 mm Inlet hose 1650 mm 1250 mm Power cord excl plug 1650 mm 1650 mm Left hand side Right hand side 2 2 1 599685B DD60S TALL installA2 NZGB indd 6 7 09 3 48 15 PM...

Страница 5: ...Clip all four side mounting brackets into their slots using a flat bladed screwdriver Ensure they re securely fitted before sliding product into cavity The mounting slots are in pairs one on each sid...

Страница 6: ...ng brackets are being used ensure they re securely fitted before sliding product into cavity max 19 mm a pair of optional brackets on the top a pair of fixing holes on the bottom a pair of formed brac...

Страница 7: ...drain hose joiner 19 mm waste tee HIGHLOOP min 150 mm Ensure hoses are routed straight to joiner Remove excess hose material if necessary DishDrawer and Standpipe 38 mm Fit the supplied rubber washer...

Страница 8: ...akage Spray arm Excessive water remaining above the filter plate after the rinse cycle Check for kinked drain hoses or blocked waste connection highloop not properly installed or drain hoses not route...

Отзывы: