9
PLUMBING & ELECTRICAL CONSIDERATIONS
SERVICE DIMENSION
LEFT SIDE*
RIGHT SIDE*
MM
MM
A
Length of drain hoses
2000
1800
B
Length of power cord**
1650
1650
C
Length of inlet hose
1650
1250
D
Distance from floor to top of hose support
750 – 883
750 – 883
E
Minimum distance from floor to end of drain hoses***
500
500
F
Minimum inlet hose radius
200
200
G
Maximum distance from cabinetry centre of electrical outlet
450
450
*dimensions taken from the chassis edge where applicable
**excluding plug
***standpipe install illustrated. Distance is the same for all plumbing installs.
a
a
b c
b
c
d
d
e
e
f
f
Hose and cord lengths
z
Your services can be installed to
either
the left-hand or right-hand side
of the product in an adjacent cabinet. Refer to 'Cabinetry preparation'
for service access requirements.
z
If the drain hoses supplied are not long enough to reach your services,
you may purchase a Fisher & Paykel drain hose extension kit which will
extend the drain hoses by 3.6m (part number 525798).
Water connection
z
Recommended water temperature: Cold (maximum 60°C)
z
3/4" BSP (GB20) to suit flat washer
z
Ensure water connection complies with local plumbing regulations.
Water pressure
z
Water softener models: max. 1 MPa (145 psi), min. 0.1 MPa (14.5 psi)
z
Non-water softener models: max. 1 MPa (145 psi), min. 0.03 MPa (4.3 psi)
Electrical requirements
z
220 – 240V min 4.8A