28
Level Machine
Check the dryer is level, and make necessary adjustments.
Adjust all 4 leveling legs to match washer height. Dryer MUST BE LEVEL and rest firmly on all 4
leveling legs.
Final Installation Check List
Check that:
No plastic or flexible metal foil is used in the exhaust ducting.
Exhaust is rigid ducting or thick wall flexible metal ducting.
All joints in the ducting are made with duct tape. It must not be connected with screws or other
fastening devices which extend into the inside of the duct.
Ducting is clean and is connected to the dryer.
Dryer is level.
Additionally for Electric Dryer Models Only, Check:
Dryer is plugged or directly wired into an approved fitting and is properly grounded.
Dryer starts, heats, cools and shuts off.
Additionally for Gas Dryer Models Only, Check:
Dryer is plugged into an approved fitting and is properly grounded.
All fittings in the gas line are tested for leaks.
Exhaust temperature increases, to confirm ignition has occurred.
– If ignition does not occur initially, it may be due to air in the gas line or low voltage power supply.
– The gas regulator valve may fail to open if the power supply falls below 105 Volts.
Level side-to-side
Level front-to-back
4 leveling legs