21
8.3 Fault codes
Err3
NTC1 open circuit or short circuit
Temperature is > 98
°c
Err4
Heater or sensor faulty
NTC1 temperature is <35
°c or there is less
than 5°c change in temperature within 40
mins of run time
Err9
NTC2 open circuit or short circuit
Temperature is > 98
°c
8.4 User warnings
The product enters this mode automatically if a user warning state is detected
User warnings are displayed in plain text. Multiple words are displayed one at a time with a 1 second
pause between changing from one word to another.
A short tone is sounded (USER ALARM) until any key is pressed.
The power and control knob keys are valid in user warning mode
Pause
If the dryer is left in this mode for 2 minutes the user warning will sound every 30 seconds for 3
minutes with
PAUS
showing in the display. Then the dryer will automatically start the cool down mode.
Normal cool down operation applies.
Door open
If the door is left open and the dryer is not powered off within 2 minutes the user warning will
sound every 30 seconds and
door OPEn
will show in the display, then power off after 3 minutes.
If the recovery mode is interrupted and the start pause LED is flashing, press start/pause to continue the
previous cycle or power off