20
8.1 Self diagnostic mode
8.2 Diagnostic levels
8 DIAGNOSTICS
Turn the dryer on at the supply and on at the control panel, touch the "Keylock" and "Dryness level"
buttons for 3 seconds. 2 beeps will sound to signify that the self diagnostic mode has been entered.
Door lock
Air dry
Dry temp
"0"= closed
"1" = open
NTC*
Air dry
Dryness level
F outlet NTC1
B inlet NTC2
Functional test
Time dry
Start/Pause
8888 Drum rotate CCW
7777 Drum rotate CW
6666 Large element on
5555 Both elements on
Display test
Air dry
Wrinkle free
Turns on all LEDs and
shows 8888, 7777 ... in
the 7 segment display.
Press wrinkle free to
return to self diagnostic
mode.
Continuous test mode
Delicate
Signal button
Keylock (exit diagnostic
mode)
"C on"
Choose the cycle to be
tested and press the
"Start/Pause" button.
To exit this test mode turn
the dryer off at the wall.
d00
Last user warning
d01
Cycle position of last user warning
d03
Detailed fault code
d04
Cyle count fault occured
d07
Cycle count
d08
Total hours of run time
d09
Controller version number
d10
Display version number
Enter diagnostic mode
touch "+" to toggle through the diagnostic levels, the display will alternate the diagnostic level and the
value in the 7 segment display.
* Note:
F215 shows outlet NTC1 temperature as 21.5°c
B215 shows inlet NTC2 temperature as 21.5°c