EXTERNAL VENTING PREPARATION
To prevent the build up of condensation produced by your DishDrawer™ Dishwasher, the external venting kit must be installed via one of the following options:
THROUGH SAME CABINET
THROUGH ADJACENT CABINET
THROUGH FLOOR
z
There is no minimum toe kick height for venting
the DishDrawer™ Dishwasher through the floor
below the cabinetry, the space below the floor
however, must be a sub-area of the house and have
adequate airflow.
z
A Ø57mm service hole should be created through
the side wall following the guidance under ‘Cabinetry
preparation’. In addition to this, a Ø57mm service
hole must be also be created through the shelf, the
base of the cavity and the floor to route the venting
hose through.
z
The duct is not required for this venting method.
z
Ensure all cutout edges are smooth and rounded and
the supplied edge protector is fitted if required.
z
Ensure cutout in the floor is sealed adequately.
z
A toe kick height of at least 100mm is required.
z
A Ø57mm service hole should be created through
the side wall following the guidance under ‘Cabinetry
preparation’. In addition to this, a second Ø57mm
service hole must be also be created through the
shelf and the base of the cavity to route the venting
hose through.
z
Frameless cabinetry:
A 100mm x 200mm cutout
must be created at the front of the cabinetry base to
secure the duct to.
z
Framed cabinetry:
A toe kick depth of at least 60mm
is required. In addition, a 100mm x 200mm cutout
must be created within the adjacent cabinetry base
to secure the duct to. This cutout should be set
back a minimum of 25mm from the frame edge for
optimal venting.
z
A toe kick height of at least 100mm is required.
z
A notched-out Ø57mm service hole should be
created through the side wall following the guidance
under ‘Cabinetry preparation’.
z
Frameless cabinetry:
A 100mm x 200mm cutout
must be created in the base of the adjacent cabinetry
to secure the duct to.
z
Framed cabinetry:
A toe kick depth of at least 60mm
is required. In addition, a 100mm x 200mm cutout
must be created within the adjacent cabinetry base
to secure the duct to. This cutout should be set
back a minimum of 25mm from the frame edge for
optimal venting.
FRAMED
FRAMED
FRAMED & FRAMELESS
FRAMELESS
ISO*
ISO*
ISO
FRAMELESS
25
25
200
200
200
200
100
100
100
100
Ø57
Ø57
Ø57
Ø57
Ø57
5
5
5
5
5
custom framed edge
custom framed edge
*Frameless install illustrated
*Frameless install illustrated