Fisher & Paykel DD60SCTW9 Скачать руководство пользователя страница 10

10

CABINETRY PREPARATION

SERVICE ACCESS

MOISTURE PROTECTION

REAR 

WALL

SHELF

PROFILE

SERVICE HOLE DIMENSIONS

MM

Maximum distance between rear of cavity and service hole

5

Maximum distance between shelf and service hole

10

Minimum diameter of service hole

57

A

B

C

z

We recommend locating the service holes on either side of the DishDrawer as shown below.

z

If the hole is created through wood, ensure the edges are smooth and rounded

z

If the holes is created through metal, ensure the edge protector is fitted.

Align the supplied moisture protection 
tape to the cabinetry as illustrated

Ensure this area is free of debris 
before carefully applying the tape to 
the surface. 

1

10mm

SIDE PARTITION

SELECT CABINETRY SECURING METHOD

1

Recommended method*

*Frameless cabinetry only

METHOD A

 

Secure to cabinetry via brackets

METHOD B

 

Secure via drawer removal

If securing via the drawer removal method, 
ensure the marked locations provide 
adequate support.

If there are no side partitions, construct timber 
bracing to secure the fixings to.

Содержание DD60SCTW9

Страница 1: ...INSTALLATION GUIDE CONTEMPORARY DD60SAW9 DD60SAX9 DD60SCW9 DD60SCX9 DD60SCTW9 DD60SCTX9 DD60SDFX9 DD60SDFTX9 DD60SDFTB9 SINGLE DISHDRAWER DISHWASHER NZ AU UK IE...

Страница 2: ......

Страница 3: ...llation of this DishDrawer requires basic mechanical and electrical skills z Installation must comply with your local building and electricity regulations z Remove all packaging materials supplied wit...

Страница 4: ...r 1 Powered driver Pliers Box cutter Router Pencil Multi tool Moisture protection tape 1 Wire clip 1 16mm Phillips screws 7 Clamp 1 Supplied Not supplied PARTS SUPPLIED TOOLS REQUIRED To access instal...

Страница 5: ...410 454 B Overall width 599 599 C Overall depth 573 573 D Depth of chassis 553 553 E Height of door panel 394 438 F Depth of door panel 20 20 G Ventilation gap below door panel 8 8 H Height from top...

Страница 6: ...B Overall width 599 599 C Overall depth 573 573 D Depth of chassis 553 553 E Height of door panel 398 470 F Depth of door panel 20 20 G Ventilation gap below door panel 8 8 H Height from top of drawer...

Страница 7: ...all height 410 B Overall width 599 C Overall depth 573 D Depth of chassis 553 E Height of door panel 394 F Depth of door panel 20 G Ventilation gap below door panel 8 H Height from top of drawer panel...

Страница 8: ...ncluding 19mm door panels on adjacent cabinetry For more information on service requirements refer to Plumbing electrical considerations and Cabinetry preparation CABINETRY CLEARANCES MM A Minimum cle...

Страница 9: ...cord lengths z Your services can be installed to either the left hand or right hand side of the product in an adjacent cabinet Refer to Cabinetry preparation for service access requirements z If the d...

Страница 10: ...are smooth and rounded z If the holes is created through metal ensure the edge protector is fitted Align the supplied moisture protection tape to the cabinetry as illustrated Ensure this area is free...

Страница 11: ...al 1 3 4 5 2 Replace the trim cover and repeat for the remaining brackets Push the product into the cavity pulling the hoses through as you push to avoid crushing or twisting them Push the product in...

Страница 12: ...he drawer off the runners and carefully set aside on a protected surface Push runners back in Take care not to pull drawer out too far to prevent any strain on the hoses Where possible protect the bas...

Страница 13: ...re hose is routed straight to the joiner removing excess drain hose if necessary Do not shorten the inlet hose Unplug or drill out the waste tee before securing joiner to sink trap or waste tee Plug p...

Страница 14: ...fitted and that it s tightened If connecting the drain hose to the sink trap ensure the highloop is a minimum 150mm higher than the drain hose joiner Water softener models adjust the water softener se...

Страница 15: ...kinked or the connection to drainage pipe may be blocked 1 Ensure the drainage hose and connection to pipes are not blocked 2 Press once to stop the beeping then again to clear the fault 3 Press to r...

Страница 16: ...ge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications...

Отзывы: