18
INSTALLATION
Leak Testing
IMPORTANT!
Gas leak testing must be carried out by a qualified technician.
General
Regularly check the whole system for leaks, or immediately check if the smell of gas is detected.
Before Testing
Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle,
brush, or rag to apply the solution to the fittings. For LP units, check with a full cylinder.
To Test
Make sure all control valves are in the “OFF” position. Turn the gas supply “ON”. Check all
connections from the supply line, or LP cylinder. Apply the soap solution around the connection,
tubing and end of the manifold. Soap bubbles will appear where a leak is present. If a leak is
present, immediately turn off gas supply, tighten any leaking connections, turn gas on, and recheck.
If you cannot stop a gas leak turn off the gas supply and call your local gas utility, or the dealer you
purchased the appliance from. Only those parts recommended by the manufacturer should be used
on the grill. Substitution can void the warranty.
IMPORTANT!
y
Do not use the grill until all connections have been checked and do not leak.
y
Check all gas supply fittings for leaks before each use. Keep a spray bottle of soapy water near the
gas supply shut-off valve. Spray all the fittings, bubbles indicate leaks
BOTTOM OF UNIT
LEAK TEST POINTS
CHECK HOSES
FOR SIGNS OF
CRACKS, LEAKS
OR ABRASIONS
BOTTOM OF UNIT
LEAK TEST POINTS
FIG. 11 LP Gas - cart
FIG. 12 LP Gas - built-in
FIG. 10 Nat. Gas
BOTTOM OF UNIT
LEAK TEST POINTS
CHECK HOSES
FOR SIGNS OF
CRACKS, LEAKS
OR ABRASIONS
Содержание DCS BE1-36R
Страница 2: ......
Страница 8: ...6 BE1 36R BE1 48R GRILL MODELS ...
Страница 25: ...EN ...
Страница 48: ......
Страница 54: ...6 BE1 36R BE1 48R GRILL MODÈLES ...
Страница 71: ...FR ...
Страница 94: ......
Страница 95: ......