background image

Important!

Disconnect power to surrounding appliances before preparing cavity.

Recommended to allow the vertical removal of the refrigerator bins.

WARNING!

Electrical shock hazard

Disconnect product from main power supply before installing appliance.

Failure to do so may result in electrical shock or death

Important safety precautions! 

Installation of the CoolDrawer™ requires competent mechanical and electrical skills.
Be sure to leave these Instructions with the Customer.
Installation must comply with your local building and electricity regulations.
At the completion of the CoolDrawer™ installation, the Installer must perform the Final Checklist.
Remove all packaging materials supplied with the CoolDrawer™.
The CoolDrawer™ is manufactured for indoor use only.

Important!  

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website 

fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

WARNING!

Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

1

The CoolDrawer™ MUST be installed to allow for future removal from the enclosure if service is required. 
Do not seal the CoolDrawer™ into the cabinetry with silicone or glue. Doing so will make future servicing 
difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in 
product, nor for repairing any damage that may be incurred by doing this. 
Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the
power supply cord.
Failure to install the CoolDrawer™ correctly will invalidate any warranty or liability claims.
If the power supply cord is damaged, it must be replaced. Parts are available from your Authorised
Fisher & Paykel dealer.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capacities, or lack of experience and knowledge unless they are supervised or given instruction 
concerning use of the appliance. 
Cabinetry must be sufficiently robust to support a combined product and food load of 220 lb (100 kg).
Bearers may be required to support the internal shelf.

Before you install the CoolDrawer™, please ensure that

The switched power outlet must be outside the refrigerator drawer cavity so that it is accessible after
installation.
The switched power outlet must be located outside the cavity, within 55” (1400 mm) from the
CoolDrawer™ cavity if situated on the left-hand side of the cavity and within 33 

1/2

” (850 mm) if situated on 

the right-hand side of the cavity. 
The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit 
through.

PARTS SUPPLIED

4

5

CAVITY PREPARATION

WARNING!

Tipping hazard

Do not operate this apppliance until it has been securely anchored inside the

cabinetry. The cabinet must be securely anchored to the floor.

Failure to use caution could result in injury or cuts.

Installation

trims (2)

Installation brackets 

(left-hand and right-

hand side) (2)

Outlet duct (1)

Trim brackets (4)

Drawer Panel 

attachment 

hooks (3)

Power 

cord (1)

Note: Ser

vices can be loca

ted

either side of C

oolDrawer™.

Benchtop

Panel

Phillips

5/8” (16 mm) 

wood screw (6)

Pan Head

5/8” (16 mm)

screw (12)

Pan Head

5/8” (16 mm) 

screw (2)

Phillips 5/8”

(16 mm ) 

wood 

screws (6)

2

PRODUCT DIMENSIONS

Product dimensions

 

(inches [mm]) 

C

oolDr

aw

er™

RB36S 

RB90S

A

overall height of product 

(inc. installation brackets)

25 3/16” (640)

B

overall width of product

33 11/16” (855)

C

overall depth of product

 

(excl. drawer panel; inc. power cord)

21 15/16” (557)

D

depth of drawer

(open) 

(excl. handle)

20 1/2” (520)

Installation diagrams for illustration purposes only

A

D

H

Cabinetry dimensions

 

(inches [mm]) 

C

oolDr

aw

er™

RB36S 

RB90S

A

overall width of cabinetry frame

35 1/2” (900)

B

minimum inside width of cabinetry frame

34” (864)

C

internal height of cabinetry to top of spacer block

25 3/8” (644)

D

internal height of cabinetry*

(to allow for product and outlet duct height)

min. 26 1/4” (665)

max. 30 1/16” (764)

E

minimum height of toe kick

3” (75)

F

minimum depth** of toe kick

1 5/8” (40)

G

minimum distance from front of cabinetry to rear wall

22 1/16” (560)

H

width of spacer blocks

1 15/16” (50)

*Minimum internal height of cabinetry can be 25 3/8” (644 mm) if outlet duct is not used.

**All depth measurements are taken from the front face of the cabinetry frame (not drawer panel)

Minimum clearances

 

(inches [mm]) 

1/2” (13 mm)

1/16” (2 mm)

E

B

C

D

G

F

F

C

G

6

INTEGRATED PANEL PREPARATION

A

B

3

CABINETRY DIMENSIONS

An internal shelf can be used as an alternative to spacer blocks to

position the product at the correct height. In this case additional 

cutouts will be required. Refer to Step 7.

Installation diagrams for illustration purposes only

Draw

er P

anel

5/8 - 3

/16” (

16-20 mm)

False P

anel

35 

1/4”  (896 mm)

height of False Panel

3/16” (4 mm)

D

 height of 

Drawer 

Panel

Benchtop

D

ra

w

er panel

False panel

 A

D

E

C

B

Integrated Panel material

5/8 - 13/16” (16 - 20 mm) panel thickness (3/4” [18 mm] recommended). 
Maximum weight of 15.5 lb (7 kg).
Adequately sealed to withstand moisture (122

O

F/50

O

C @ 80% RH).  

Height of Drawer Panel 

The following information is required to correctly define your drawer panel height:

 

Dimension

Data 

Source

A

 

Clearance between top of Drawer panel and underside 

Your kitchen designer

 

of 

benchtop

B

 

Height between underside of cabinetry ceiling 

Your kitchen designer

 

and underside of benchtop 

C

 

Internal height of cabinetry to top of spacer block 

25 3/8” (644 mm)

D

 

Drawer panel height 

Calculated from A, B, C & E

E

 

Bottom face of Drawer panel to top of spacer block 

Your kitchen designer 

(to ensure that bottom cover of product is not exposed) 

(Min. 6 1/16” [154 mm])  
(Max. 

1/4” [184 mm])

To calculate D complete the following equation:

D = C + B - A - E

i.e. For the F&P prefinished panel:
18 3/4” (476 mm)  =  25 3/8” (644 mm) + 11/16” (18 mm) - 1/16” (2 mm) - 7 1/4” (184 mm)

Height of the False Panel

Determine the height of the false panel according to your individual kitchen cabinetry 
requirements maintaining a 

3/16

” (4 mm) gap between panels.

F&P prefinish panel width is 35 

1/4

” (896 mm) assuming a 

1/16

” (2 mm) clearance either side of panel

height (D) is 18 

3/4

” (476 mm). 

Note B must be min. 

5/8

” (16 mm) to ensure adequate clearance to benchtop.

SIDE VIEW

max. 33 1/2” (850 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. 21” 

(535 mm)

min. 5” (130 mm)

min. ø 1 15/16” (50 mm)

max. 

3/4” 20 mm

Shows cutout if cabinetry depth at
minimum 21 5/8” (550 mm)

Installation diagrams for illustration purposes only

COOLDRAWER™ MULTI-TEMPERATURE DRAWER

INSTALLATION INSTRUCTIONS

RB36S & RB90S models

FRAMELESS CABINETRY

Содержание COOLDRAWER

Страница 1: ...nstall the CoolDrawer correctly will invalidate any warranty or liability claims If the power supply cord is damaged it must be replaced Parts are available from your Authorised Fisher Paykel dealer This appliance is not intended for use by persons including children with reduced physical sensory or mental capacities or lack of experience and knowledge unless they are supervised or given instructi...

Страница 2: ...ury or cuts 2 PRODUCT DIMENSIONS Product dimensions inches mm CoolDrawer RB36S RB90S A overall height of product inc installation brackets 25 3 16 640 B overall width of product 33 11 16 855 C overall depth of product excl drawer panel inc power cord 21 15 16 557 D depth of drawer open excl handle 20 1 2 520 Installation diagrams for illustration purposes only A D H Cabinetry dimensions inches mm ...

Страница 3: ...False Panel 35 1 4 3 16 4 mm D heightof Drawer Panel Integrated Panel material 5 8 13 16 16 20 mm panel thickness 3 4 18 mm recommended Maximum weight of 15 5 lb 7 kg Adequately sealed to withstand moisture 122O F 50O C 80 RH Height of Drawer Panel The following information is required to correctly define your drawer panel height Dimension Data Source A Clearance between top of Drawer panel and un...

Страница 4: ...ight of cabinetry to top of spacer block 25 3 8 644 mm D Drawer panel height Calculated from A B C E E Bottom face of Drawer panel to top of spacer block Your kitchen designer to ensure that bottom cover of product is not exposed Min 6 1 16 154 mm Max 7 1 4 184 mm To calculate D complete the following equation D C B A E i e For the F P prefinished panel 18 3 4 476 mm 25 3 8 644 mm 11 16 18 mm 1 16...

Страница 5: ...not already have cutouts ensure the modifications below are made Important Ensurethepowercordisclippedinplace Secure using vertical or horizontal fixing CREATE CUTOUTS IN FRAME 7 LOCATE SECURE INSTALL BRACKETS 8 Important Cutoutletducttobeflush withtopofspacerblocks 9 ATTACH OUTLET VENT DUCT 10 ATTACH POWER CORD TRIM BRACKETS Important Notecorrectorientationofbracket Only with cabinetry with inter...

Страница 6: ... adjust the TOP attachment hooks as necesary Replace panel on drawer and confirm vertical clearances Slide panel to achieve horizontal clearances Open drawer and clamp panel onto drawer by tightening the BOTTOM attachment hook Close the drawer and ensure it is flush with adjacent cabinetry If not the product may have to be pulled back or forward Important Becarefulnottodamagepower supplycordwhenpu...

Страница 7: ... 17 CHECK OPERATION Open drawer and secure product to cabinetry using four Trim brackets and screws 18 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Has all packaging been removed from the appliance Is the appliance securely fastened to the cabinetry Does the drawer slide freely and close properly Has the outlet duct been installed correctly Is the appliance level Are the panels securely attach...

Страница 8: ...e appliance level Are the panels securely attached Have the panels been properly aligned for correct operation and appearance Are all clearances even Is there clearance between drawer and cabinetry frame Has the power cord been plugged into a properly earthed 3 prong outlet which has been installed in accordance with all applicable electrical codes OPERATION Is the control panel lit Can you hear t...

Отзывы: