VENTILATION REQUIREMENTS
WALL INSTALLATION
ISLAND INSTALLATION
Non-combustible
Non-combustible
Combustible
Combustible
z
Ventilation hoods and blowers are designed for use with single wall ducting, however some local building codes or inspectors may require double wall ducting and/or a damper. Consult local
building codes and/or agencies, before installing to ensure local requirements are met. Semi-rigid ducting is recommended for maximum effectiveness.
z
Hood blower speeds should be variable to reduce noise and loss of household air.
z
Due to a high volume of ventilation air, a source of make-up air (outside replacement air) is recommended. This is particularly important for tightly sealed and insulated homes. A reputable
heating and ventilating contractor should be consulted.
C
C
C
C
A
A
B
B
VENTILATION UNIT
WALL INSTALLATION RECOMMENDATIONS
Hood
A
min. 30" (762mm)
max. 42 (762mm)
B
min. 36" (914mm)
max. 42 (762mm)
C
min. 19" (480mm)
Blower
30" Cooktop
min. 550 CFM
36" Cooktop
min. 550 CFM
VENTILATION UNIT
ISLAND INSTALLATION RECOMMENDATIONS
Hood
A
min. 30" (762mm)
max. 42 (762mm)
B
min. 36" (914mm)
max. 42 (762mm)
C
min. 19" (480mm)
Blower
30" Cooktop
min. 550 CFM
36" Cooktop
min. 550 CFM