Installing a thermal protection barrier
If the cooktop is installed over drawers or cupboards and its underside surface thus
becomes accessible after installation, a thermal protection barrier must be fitted at least 40
mm (for CE302 models) or 30 mm (for CE604 models) beneath the base of the cooktop
(see Figs. 5 and 6). This barrier must be made of low thermal conductivity material installed
according to the instructions for installation.
• The requirement above is not applicable if the cooktop is installed directly above an oven.
• For access to the cooktop for servicing or installation, ensure that the barrier can be removed
from beneath.
• A gap of 20 mm may be allowed at the rear of the barrier (see Fig.7) for electrical connection
and ventilation.
Fastening the installation brackets
• Each cooktop is provided with an installation kit including brackets and screws for fastening the cooktop to
benches from 20 to 40 mm thick.
• CE302 models are provided with four F type brackets.
• CE604 models are provided with two R type brackets (for the rear of the cooktop) and two F type brackets (for
the front of the cooktop).
1. Create a cutout according to the dimensions in Fig.3 or Fig.4.
https://producthelp.fisherpaykel.com/au/Cook/Cooktops/Electric/Two_Burners/CE302CPX1/User_Guide_CE302CPX1/02_Installation_instructions
Updated: Sat, 09 Mar 2019 07:23:30 GMT
Powered by