48
Does the
display
module
indicate a
fault code?
Refer to Section
6.2.1
Repair or replace
faulty components
Replace
power/control
module
Refer to Section
10.12
Replace display
module
Is there
power to the
refrigerator?
Check house
outlet socket
No
Yes
Has product
been
initialised?
Is there 12V
DC between the
power/control module
and the display
module?
No
Is there
power to the
power/control
module?
Are any
L.E.D.s on at
the display
module?
Is the
compressor
warm?
Yes
Yes
Is there 12V
DC at the
display
module?
Repair or replace
faulty components
No
With FC door
closed and PC
door open, press
Mode button
No
Yes
No
No
Yes
No
Yes
Yes
Refer to Section
10.13
10 FLOW
DIAGRAMS
10.1 Refrigerator Not Operating