6 Technical data
6.1 General
Please also observe the order code here.
6.2 Application conditions
Ambient temperature
-10 … +70 °C
Storage temperature
-20 … +85 °C
Max. temperature of medium
Depends on model
Specific minimum density of medium
ρ = 0.6 kg/dm
3
Installation position
horizontal
Type of protection
IP 55 acc. to DIN EN 60529
Variant
Max. working pressure:
Max. temperature of medium
NK10 1 …
20 bar
400°C
NK10 2 …
20 bar
400°C
NK10 3 …
10 bar
350°C
NK10 4 …
16 bar
400°C
NK10 5 …
16 bar
400°C
NK10 6 …
20 bar
400°C
NK10 7 …
20 bar
400°C
NK10 A …
10 bar
350°C
NK10 B …
20 bar
400°C
NK10 F …
20 bar
400°C
NK10 G …
20 bar
400°C
NK10 H …
20 bar
400°C
NK10 K …
150 lbs
400°C
NK10 M …
300 lbs
400°C
NK10 N …
300 lbs
400°C
NK10 P …
300 lbs
400°C
6.3 Switch contacts
Maximum load data at ohmic load.
250 V AC
6A
250 V DC
250 mA
6.4 Measurement accuracy
Switch hysteresis
approx. 6 mm
Switching point differential between S1 and
S2
(+)
max. 30 mm
Switching point differential on the
medium surface
dependent on medium density
(+)
only for two micro-switches
Содержание NK10 B
Страница 1: ...Operating manual NK10 Fill Level Limiter 09005111 BA_EN_NK10 Rev ST4 E 01 19 09005111 ...
Страница 19: ...FISCHER Mess und Regeltechnik GmbH Attachments 8 BA_EN_NK10 19 28 Fig 13 CE_DE_NK10 part2 ...
Страница 22: ...8 Attachments FISCHER Mess und Regeltechnik GmbH 22 28 BA_EN_NK10 Fig 16 DNVGL_TAA000020S_Page_2 ...
Страница 23: ...FISCHER Mess und Regeltechnik GmbH Attachments 8 BA_EN_NK10 23 28 Fig 17 DNVGL_TAA000020S_Page_3 ...
Страница 27: ...FISCHER Mess und Regeltechnik GmbH Attachments 8 BA_EN_NK10 27 28 Fig 21 SIL_IEC61508_DE_EN 1 Part2 ...