13. Ordering Code

Differential Pressure 

  Transmitter 

DE61

Measuring Range

0...0.25 mbar.................................................................... >

9

4

0...0.4   mbar.................................................................... >

9

5

0...0.6   mbar.................................................................... >

9

6

0...1.0   mbar.................................................................... >

5

1

0...1.6   mbar.................................................................... >

9

7

0...2.5   mbar.................................................................... >

9

8

0...4.0   mbar.................................................................... >

5

2

other measuring ranges (please indicate in plain text) .... >

9

9

Pressure Connection

Female thread G ¼..........................................................................>

0

1

Cutting ring connection brass for 6 mm tube ...................................>

2

8

Cutting ring connection brass for 8 mm tube ...................................>

2

9

Cutting ring connection brass for 10 mm tube .................................>

3

0

Screw connection AI for 6 mm flexible tube.....................................>

4

0

Screw connection AI for 8 mm flexible tube.....................................>

4

1

Electrical Output Signal

0–20 mA linear, 3-wire .....................................................................................>

A

4–20 mA linear, 2-wire, only 24 V DC, without contacts and square-root 
extraction .........................................................................................................>

B

0–20 mA square-rooted, 3-wire .......................................................................>

E

4–20 mA square-rooted, 3-wire .......................................................................>

F

4–20 mA linear, 3-wire .....................................................................................>

P

Supply Voltage

24 V DC ....................................................................................................................>

9

Indication / Switching Sections

Without indication / without contacts.................................................................................>

0

3½ digit LC-display / without contacts...............................................................................>

1

3½ digit LC-display / with 1 potential-free contact ............................................................>

2

3½ digit LC-display / with 2 potential-free contacts...........................................................>

5

Electrical Connection

Internal connector bloc .............................................................................................................>

E

M12 plug connection.................................................................................................................>

M

 

     

9

Содержание DE61

Страница 1: ...instructions use of this pro duct for purposes for which it is not intended and or operation of this product outside the limits spe cified for any of its technical parameters can result in harm to per...

Страница 2: ...ssure safe shock and vibration resistant and long time stable The differential pressure acts on the sensor element and effects a measuring signal The electronic amplifier then generates an electrical...

Страница 3: ...mA Correct offset using zero point potentio meter N Mount housing cover 5 4 Switching Point Adjustment The instrument s main board has two calibration poten tiometers and a coding switch to set switch...

Страница 4: ...ust be read thoroughly to ensure that all of them work correctly when connected together 7 Transport The product must be protected against shock and vibra tion during transport It must therefore be pr...

Страница 5: ...Measuring indication 3 digit LC Display Switching point adjustment The digital display can be switched over between the differential pressure actual value and the switch point adjustments via selector...

Страница 6: ...6 12 Dimensions all units in mm unless stated otherwise Mounting holes 4 5 mm Cable gland M16 x 1 5...

Страница 7: ...0 Screw connection AI for 6 mm flexible tube 4 0 Screw connection AI for 8 mm flexible tube 4 1 Electrical Output Signal 0 20 mA linear 3 wire A 4 20 mA linear 2 wire only 24 V DC without contacts an...

Страница 8: ...ange without notice Changements techniques sous r serve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesstechnik de...

Отзывы: