FISCHER Mess- und Regeltechnik GmbH
Technical data | 6
BA_EN_DE45_ATEX_LCD
29/40
6 Technical data
Please also observe the order code here.
6.1 Input variables
Measuring variable
: Differential pressure for gas-like media
Measuring Range
Stat. operating
pressure max.
Bursting
pressure
mbar
Pa
kPa
mbar
mbar
0…4
0…400
0…0.4
50
150
0…6
0…600
0…0.6
50
150
0…10
0…1000
0…1.0
100
300
0…16
0…1600
0…1.6
100
300
0…25
---
0…2.5
250
750
0…40
---
0…4.0
250
750
0…60
---
0…6.0
500
750
0…100
---
0…10.0
500
750
0…160
---
0…16.0
1500
3000
0…250
---
0…25.0
1500
3000
±2.5
±250
±0.25
50
150
±4
±400
±0.4
50
150
±6
±600
±0.6
50
150
±10
±1000
±1.0
100
300
±16
±1600
±1.6
100
300
±25
---
±2.5
250
750
±40
---
±4.0
250
750
±60
---
±6.0
500
750
±100
---
±10.0
500
750
6.2 Output parameters
Analogue output:
Output
Signal range
Load
0…20 mA
0,0…21,0 mA
U
b
≤ 26 V : R
L
≤ (U
b
– 4 V) /0,02 A
U
b
> 26 V : R
L
≤ 1100 Ω
4…20 mA
0,0…21,0 mA
0…10 V
0,0…11,0 V
R
L
≥ 2 kΩ
Switching outputs:
2 potential-free semiconductor switches (MOSFET)
MOSFET
Progr. switching function
One-pin activator (NO)
One-pin deactivator (NC)
Max. switching voltage
3…32 V AC/DC
Max. switching current
0.25A
max. switching output
8 W / 8 VA
R
ON