General Instructions and Regulations
9.12.14
Kapitel/Chapter 3: General Instructions and Regulations - Seite/Page 25
Observe the applicable instructions concerning fire and explosion protection of the battery
manufacturer.
Install a fuse of appropriate size in the positive connection of the starter battery. Install as close to
the battery as possible but with a max. distance of 300 mm (12 in) from the battery.
The cable from the battery to the fuse shall be protected with a conduit/protective sleeve against
fraying.
Use self-extinguishing and fire-protected cables for installation that are designed for max. temperatures of 90 °C,
195 °F.
Install the battery cables in such a way that the insulation cannot be removed by chafing or other mechanical
stresses.
The battery terminals must be protected against accidental short-circuiting.
Inside the Fischer Panda generator capsule, the positive battery cable must be routed so that it is protected from
heat and vibrations by means of an adequate conduit/protective sleeve. It must be installed so that it does not come
into contact with rotating parts or such that heat up during operation such as pulley, exhaust manifold, exhaust pipe,
and motor itself. Do not overtighten the cable, as it may be damaged otherwise.
After completing the installation, perform a test run of the generator and check the battery cable installation during
and after the test run. Implement corrections as necessary.
Fig. 3.6-1: Sample diagram for starter battery installation
3.6.4 General safety instructions for handling batteries
These instructions shall apply in addition to the instructions of the battery manufacturer:
• While you are working on the batteries, a second person should be within earshot to help you if
necessary.
• Keep water and soap ready in case battery acid is burning your skin.
• Wear eye protection and protective clothing. Do not touch your eyes while handling batteries.
Содержание 10000/9
Страница 10: ...Seite Page 10 Kapitel Chapter 2 9 12 14 Leere Seite Intentionally blank...
Страница 62: ...The Panda Generator Seite Page 62 Kaptitel Chapter 6 The Panda Generator 9 12 14...
Страница 220: ...Tables Seite Page 220 Kaptitel Chapter 11 Tables 9 12 14...
Страница 244: ...Seite Page 244 Kapitel Chapter 13 General operation 9 12 14 Leere Seite Intentionally blank General operation...
Страница 246: ...Seite Page 246 Kapitel Chapter 14 Measurements 9 12 14 Leere Seite Intentionally blank Measurements...