Fischer Amps SHAKER AMP 400 Скачать руководство пользователя страница 3

Shaker-Amp-400-E-2016-12.doc 

Actuators and Connections Back Side 

 

 
 
 
 
 
(1 ) 

Mic. / Line-Input  (XLR-jack combi plug) 
 

Signal input for the microphone or line input (balanced). 

 

This input also handles unbalanced signals with a mono jack connector. 
Unbalanced signals with an XLR connector require that Pin 3 and Pin 1 
of the plug are connected to audio ground. Phantom power is only 
possible with balanced input signal of the microphone.  

(2) 

Mic. / Line-Out / Thru-Out (XLR-male) 
 

This input allows to loop the input signal to another unit.  
The output and the input have a non-switched connection and function 
even when the Shaker Amp is switched off. Here the phantom power is 
output as well. This means that when two units are connected (Shaker 
Amp and e. g. mixing console), only activate one of the 48V phantom 
supplies.  

 
(3) 

Jack ¼ ‘’ Input/Output  

 

Balanced 

¼ ‘’ jack In/Out parallel to the XLR-Input. 

 
(4) 

Speakon-Power Amp Out  

 

Speakon output to connect the tactile transducer or loudspeaker. Jack 1 
+ and 1 

– are assigned at the quadripolar Speakon output.  

The amplifier generates 500 watts max. into 4 ohms.  

 
(5) 

Binding Post Output 

parallel to the Speakon Output 

 
(6) 

Ground Lift Button

 

Separates the audio ground from the system and cabinet ground. When 
there is a ground loop when connecting various appliances, pressing the 
Ground Lift button can solve the problem (the cabinet of the Shaker 
Amp 400 is still connected with the protective ground of the power 
supply). 

(7) 

Input Voltage Select 
115V /230V 

Switch to adjust the appliance to the country’s supply voltage 230V AC 
or 115V AC. Before switchover, always switch off the appliance and 
disconnect the mains cable from the operating voltage. Doing so 
prevents overload of the internal PSU.  

 
(8) 

Fuse holder 

Fuse holder with the 2.0 A power fuse for use with AC power 230V, for 
use with 115V AC change the fuse to a 4 AT.  

 

(9) 

AC Power Input Connection 
 

IEC 3 pole jack to plug in the power cable. Pay attention that the mains 
voltage is correct.  

 

 