Chapter V Functional Parameter TableHigh-performance Universal Inverter User Manual

— 48 —

30-15

PID set point

0.1%

0x700F

28687

30-16

PID feedback values

0.1%

0x7010

28688

30-17

PLC and multisegment
current segments

1

0x7011

28689

30-18

HDI incoming frequency 0.01K Hz

0x7012

28690

30-19

continue to have

0x7013

28691

30-20

Frequency converter
model

1

0x7014

28692

30-21

Rated power of the
frequency converter

0.1K W

0x7015

28693

30-22

Power converter rated
voltage

1V

0x7016

28694

30-23

Power converter rated
current

0.1A

0x7017

28695

30-24

linear velocity

1m/Min

0x7018

28696

30-25

This operation time

1Min

0x7019

28697

30-26

The slope gives a given
frequency

0.01Hz

0x701A

28698

30-27

The torque is quantified

0.1%

0x701B

28699

30-28

output torque

0.1Nm

0x701C

28700

30-29

Digital regulation

0.01Hz

0x701D

28701

30-30

torque current

0.1A

0x701E

28702

30-31

exciting current

0.1A

0x701F

28703

30-32

Motor power factor

0.01

0x7020

28704

30-33

Estimate motor
frequency

0.01Hz

0x7021

28705

30-34

AC incoming current

0.1A

0x7022

28706

30-35

Motor overload count
value

1

0x7023

28707

Содержание T5R5GB

Страница 1: ...ully before use The equipment supporting manufacturer should send this manual to the end user along with the equipment to facilitate the subsequent use of reference matters need attention To illustrat...

Страница 2: ...installation hole position of the frequency converter 9 3 2 Wiring 10 Chapter 4 Keyboard Display and Operation 13 4 1 Introduction of the L E D keyboard interface 13 4 2 Description of function code v...

Страница 3: ...please do not install it pay attention to Handling should be carried lightly and put gently otherwise there is a danger of damage to the equipment Do not use damaged drives or missing drives there is...

Страница 4: ...on the power input terminal R S T and output terminal U V W is correct and check whether the peripheral circuit connected to the driver is fastened otherwise the drive is damaged Any part of the drive...

Страница 5: ...drive start and stop otherwise it will cause equipment damage Maintenance danger Do not repair and maintain the equipment with live power otherwise there is a danger of electric shock Cut off the inpu...

Страница 6: ...nstration of the type Figure 2 2 Model Description 2 2 Product Series Description Table 2 1 Model and technical data of high performance general frequency converter Frequency converter model Power cap...

Страница 7: ...ltage Single phase 3 phase 220V model 200V 240V Three phase 380V model 380V 440V Voltage allowable fluctuation range 15 10 Input power frequency 50Hz or 60Hz with a fluctuation of less than 5 output m...

Страница 8: ...MODBUS communication input terminal Five digital input terminals one of which is a high speed pulsed HDI input Two analog quantity input terminals leading out terminal 2 Digital output terminals one...

Страница 9: ...Figure 3 2 Outline dimensions of frequency converter product model Installation hole position mm outline dimension mm Installation aperture Net quantity remarks A B H W D mm Kg Single phase 220V S0R4G...

Страница 10: ...mensions and Installation Size 3 2 Wiring 3 2 1 standard wiring diagram Figure 3 3 Standard wiring diagram K2 relay is not installed by default and can be selected according to customer requirements 3...

Страница 11: ...op terminal of the three phase frequency converter Terminal mark name explain R S T Three phase power supply input terminal AC input three phase power connection point Positive and negative DC bus ter...

Страница 12: ...e voltage current is selected by the 06 10 menu 2 Input impedance voltage input impedance 20K current input impedance 510 AI2 GND Analog quantity input terminal 2 figure import X1 COM Digital input 1...

Страница 13: ...the following figure Figure 4 1 Schematic diagram of the operation panel 1 Function indicator light instructions RUN when the lamp is out the converter is down and when the lamp is on the converter is...

Страница 14: ...shutdown and running display interface select the display parameter when modifying the parameter select the parameter RUN Run the key In keyboard operation mode used for running operations STOP RES ET...

Страница 15: ...stant torque load 1 P type fan water pump type load 0 00 01 Motor control mode 0 Keep 1 No speed sensor vector control 2 with torque control 2 V F control 2 00 02 Run the command source selection 0 Ke...

Страница 16: ...requen cy 00 09 630 00Hz 50 00Hz 00 12 upper limiting frequency 00 10 00 08 50 00Hz 00 14 Lower limit frequency 0 00Hz 00 09 0 00Hz 00 15 carrier frequency 1 0 15 0K Hz Model determination 00 16 Zero...

Страница 17: ...tor resistance 0 001 65 535 Model determination 01 09 Motor leakage resistance 0 1 6553 5mH Model determination 01 10 Motor mutual resistance 0 1 6553 5mH Model determination 01 11 No load current of...

Страница 18: ...inimum voltage V1 0 0 V2 0 0 02 09 V F transition compensation gain 0 0 200 0 100 0 02 10 The V F low frequency oscillatory suppression coefficient 0 100 10 02 11 V F high frequency oscillation suppre...

Страница 19: ...ation voltage number setting 0 0 100 0 0 0 02 18 V F separation voltage acceleration time 0 0 3600 0s 0 0s 02 19 V F separation voltage deceleration time 0 0 3600 0s 0 0s 02 20 V F separation voltage...

Страница 20: ...in 50 200 100 03 09 The ACR current loop K P 0 65535 1000 03 10 The ACR current loop K I 0 65535 1000 03 11 Vector 2 constant power weak magnetic constant 0 1 2 0 0 3 03 12 Constant power minimum weak...

Страница 21: ...mber setting 04 05 and 04 06 1 AI1 2 AI2 3 AI3 4 HDI 5 Multi section speed 6 RS 485 communication 7 Keyboard analog potentiometer 0 04 04 Reverse torque ceiling frequency source ditto 0 04 05 Forward...

Страница 22: ...then start it 2 Speed tracking to start 0 05 01 Start frequency 0 00 50 00Hz 0 50Hz 05 02 Startup frequency retention time 00 0 50 0s 0 0s 05 03 Start the DC brake current 0 0 100 0 0 0 05 4 Start the...

Страница 23: ...e by speed 1 05 20 Feedback speed detection time 0 00 100 00s 0 05s 05 21 Start delay 0 0 60 0s 0 0s 05 22 Stop speed delay 0 0 100 0s 0 0s 05 23 Brake unit action 0 Disable 1 enabled 1 05 24 Brake un...

Страница 24: ...ontrol is paused 26 Suspension pause stop at current frequency 27 Swing frequency reset back to center frequency 28 Counter reset 29 Torque speed control switch 30 Prohibition acceleration and deceler...

Страница 25: ...s 06 16 X2 terminal opening delay 0 00 50 000s 0 000s 06 17 The X2 terminal will disconnect the delay 0 00 50 000s 0 000s 06 18 X3 terminal opening delay 0 00 50 000s 0 000s 06 19 The X3 terminal will...

Страница 26: ...ve operation shutdown instruction clearance 06 35 UP terminal frequency change rate 0 01 50 00H z s 0 50H z s 06 36 Rate of change in DOWN terminal frequency 0 01 50 00H z s 0 50H z s 06 37 HDI input...

Страница 27: ...54 0 00V 06 53 The lower limit of AI3 is set accordingly 100 0 100 0 0 0 06 56 AI3 upper limit 06 54 10 00V 10 00V 06 57 The upper limit of AI3 is set accordingly 100 0 100 0 100 0 06 58 AI3 input fil...

Страница 28: ...virtual terminal output 07 02 HDO terminal output function selection 0 07 03 K 1 relay output function selection 1 07 04 K 2 relay output function selection 5 07 05 AO1 output function selection 0 Ru...

Страница 29: ...t limit limit 0 00 50 00K Hz 50 00K Hz 07 22 HDO output filtering time 0 000s 10 000s 0 000s 07 23 Y1 opening delay 0 00 50 000s 0 000s 07 24 Y1 disconnection delay 0 00 50 000s 0 000s 07 25 HDO openi...

Страница 30: ...id for the panel controls 1 Effective for both panel and terminal control 2 Effective for both panel and communication control 3 Effective for all control modes 0 08 04 Restore factory parameters 0 No...

Страница 31: ...drops 1 Zero zero when the power is dropped 00 08 08 Function code parameter replication 0 No operation 1 Function parameters are uploaded to the keyboard 2 Download the keyboard function parameters...

Страница 32: ...inverter overload percentage bright BIT6 ramp frequency given value Hz bright BIT7 Line speed BIT8 AC incoming line current BIT 9 Upper limit frequency 0000 08 11 LED shutdown display parameters 0000...

Страница 33: ...ork factor display coefficient 0 00 1 00 0 56 08 19 Cumulative running time 0 65535h 08 20 Monitor the high cumulative power consumption Cumulative power consumption 08 20 1000 08 21 0K Wh 08 21 Monit...

Страница 34: ...voltage 48 Electronic overload failure 6 Slow down over voltage 51 The initial position is dysregulated 7 Constant speed overvoltage 60 Brake pipe protection 8 9 The bus is under pressure 10 Frequency...

Страница 35: ...Operating frequency of the previous failure 09 15 Given the frequency of the previous fault slope 09 16 The previous fault output voltage 09 17 Previous fault output current 09 18 Previous fault bus...

Страница 36: ...alid 1 valid 1 10 03 Over voltage stall action voltage The 220V model 120 150 120 The 380V model 120 150 140 10 04 Overflow protection options Individual bit Overcurrent protection enables 0 Invalid 1...

Страница 37: ...ncy converter overload warning shutdown after overload 2 The frequency converter has overload warning and continue to run and stop after underload 3 Stop ter stops after underload Hundred under overlo...

Страница 38: ...nstantaneous power outage operation 0 Do not continue to operate 1 Keep running 0 10 20 Insient power outage and operation waiting time 0 0 3600 0s 1 0s 10 21 Insient power drop and frequency drop ena...

Страница 39: ...lower than Lower limit frequency operating mode 0 Run at the lower limit frequency 1 Downtime 2 Sleep 0 11 10 Sleep recovery delay 0 0 3600 0s 0 0s 11 11 Drop frequency 0 00 10 00Hz 0 00Hz 11 12 Heat...

Страница 40: ...ency check value 0 00 P00 03 50 00Hz 11 33 The FDT1 frequency detection lag value 0 0 100 0 5 0 11 34 FDT2 frequency check value 0 00 Maximum frequency 50 00Hz 11 35 The FDT2 frequency check lag value...

Страница 41: ...1 AI2 2 AI3 3 HDI 4 RS 485 communication 5 Keyboard analog potentiometer 0 12 03 PID application direction 0 Positive effect 1 Counteraction 0 12 04 Proportional gain of K P1 0 00 100 00 1 00 12 05 In...

Страница 42: ...the upper and lower limits decade 0 Consistent with the set direction 1 Opposite to the set direction hundreds place 0 Reference to the maximum frequency limit 1 Reference frequency source A limit ki...

Страница 43: ...value 100 0 100 0 0 0 13 07 Multistage speed 7 frequency setting value 100 0 100 0 0 0 13 08 Multiple segment speed 8 frequency setting value 100 0 100 0 0 0 13 09 Multistage speed 9 frequency Setpoin...

Страница 44: ...LC segment 4 runtime 0 0 6553 5 s min 0 0s min 13 21 PLC segment 5 runtime 0 0 6553 5 s min 0 0s min 13 22 PLC segment 6 runtime 0 0 6553 5 s min 0 0s min 13 23 PLC segment 7 runtime 0 0 6553 5 s min...

Страница 45: ...7 B it14 15 two bit values selected acceleration and deceleration time 1 2 3 4 0000 13 33 PLC periods 8 to 15 Value range 0x0000 0xFFFF Paragraph 8 B it0 1 two bit values selected acceleration and dec...

Страница 46: ...otentiometer 7 The preset frequency can be fine tuned 0 14 Groups of SCI communication parameters 14 00 Address of this machine 0 Broadcast address 1 247 1 14 01 Communication Porter rate 0 1200BPS 1...

Страница 47: ...0 FC name Minimum unit Address Address HEX Address Address DEC 30 Groups of monitoring parameters 30 00 running frequency 0 01H z 0x7000 28672 30 01 Set the frequency 0 01H z 0x7001 28673 30 02 busbar...

Страница 48: ...converter rated voltage 1V 0x7016 28694 30 23 Power converter rated current 0 1A 0x7017 28695 30 24 linear velocity 1m Min 0x7018 28696 30 25 This operation time 1Min 0x7019 28697 30 26 The slope give...

Страница 49: ...tor wire or motor to ensure its normal operation Err02 OC1 Accelerate over current 1 There is ground or short circuit 2 The control mode is a vector and has no parameter identification 3 Acceleration...

Страница 50: ...l the brake unit and the resistance Err07 Ov3 Constant speed overvoltage 1 High input voltage 2 There is external forces dragging the motor during operation 1 Adjust the voltage to the normal range 2...

Страница 51: ...g to remove the faulty operation Err16 CE 485 Communication fault 1 The upper position computer does not work normally 2 The communication line is abnormal 3 Communication parameter group is not set c...

Страница 52: ...3 Overload or blocked rotation 1 Motor parameter identification 2 Speed deviation detection parameters are reasonably reset 3 Check the load to ensure that the load is normal Err 48 oL3 Electronic ov...

Страница 53: ...485 asynchronous half duplex The RS485 terminal default data format is detailed in the SCI group parameters A 2 Communication mode 1 Frequency converter is a slave the main and slave peer to point com...

Страница 54: ...tiple registers 0x06 Write a single register to the frequency converter 0x10 Write multiple registers to the frequency converter data It mainly includes register address register number and register c...

Страница 55: ...urn to 0x1388 5000 or 50 00H z A 4 2 Command code 0x06 Write a single register ask PDU device address 1 Bytes 0x01 command code 1 Bytes 0x06 start address Two bytes 0x0000 0xFFFF high 8 bit address at...

Страница 56: ...Bytes 0x10 start address Two bytes 0x0000 0xFFFF high 8 bit address at first Number of registers Two bytes 0x0001 0x0010 1 16 high 8 bits in front CRC check code Two bytes CRC low 8 in the anterior a...

Страница 57: ...int16 data Uint16 len Uint16 crcValue 0xffff Uint16 i while len crcValue data for i 0 i 7 i if crcValue 0x0001 crcValue crcValue 1 0xa001 else crcValue crcValue 1 return crcValue A 7 Register address...

Страница 58: ...00 00 100 00 negative motor reversal 0x 1001 running frequency 0x 1002 busbar voltage 0x 1003 output voltage 0x 1004 output 0x 1005 output power 0x 1006 output torque 0x 1007 running speed 0x 1008 DI...

Страница 59: ...0008 Stop parking 0x2001 Output terminal function value 23 Bit0 Y1 Bit1 HDO Bit2 R 1 Bit3 R 2 14 07 0 DO output terminal control 14 07 1 the communication setting frequency 0 Fmax in unit 0 01Hz 0x200...

Страница 60: ...rotected fault code please read the Group 09 Fault Record Parameters A 8 Communication error response Communication error code list error code name description 0x01 The command code is illegal The com...

Страница 61: ...x80 to 0x83 0x 86 0x06 Write error When 0x06 When an error writes a command the command code in the responding data frame changes from 0x06 0x80 to 0x86 0x 90 0x 10 Read error When the responding data...

Страница 62: ...ro 00 03 7 PID control 06 59 10 06 60 1 Pressure sensor supply voltage 10V 20 00 10 16 kg 20 01 5 Target pressure 20 02 5 dormant pressure 20 03 3 wake up pressure 20 04 0 05 stable pressure deviation...

Страница 63: ...ters and secondary disasters C Hardware damage caused by artificial fall and transportation after the purchase D Damage caused by not following the user manual provided by our company E Failure and da...