High Performance General Inverter User Manual Chapter V Functional Parameter Table
— 47 —
FC
name
description
Factory value
attribute
selection
2: Stop without alarm (communication control
mode)
3: Stop according to shutdown mode without
alarm (all control modes)
14-06
Communication
processing action
selection
LED the unit:
0: Write the operation with a response
1: No response to the writing operation
0
○
14-07
Communication
protocol selection
0: Compatible with 380 protocol (including 00
groups, 30 groups of partial menus)
1: Compatible with GD protocol (communication
control only)
0
○
FC
name
Minimum unit
Address / Address
(HEX)
Address Address
(DEC)
30 Groups of monitoring parameters
30-00
running frequency
0.01H z
0x7000
28672
30-01
Set the frequency
0.01H z
0x7001
28673
30-02
busbar voltage
0.1V
0x7002
28674
30-03
output voltage
1V
0x7003
28675
30-04
output
0.1A
0x7004
28676
30-05
power of motor (%)
0.1%
0x7005
28677
30-06
output torque (%)
0.1%
0x7006
28678
30-07
Enter terminal status
See the 30 sets for
detailed instructions
0x7007
28679
30-08
Output terminal status
See the 30 sets for
detailed instructions
0x7008
28680
30-09
AI1 Input voltage
0.01V
0x7009
28681
30-10
AI2 Input Voltage
0.01V
0x700A
28682
30-11
AI3 input voltage
0.01V
0x700B
28683
30-12
count value
1
0x700C
28684
30-13
Length value
1
0x700D
28685
30-14
motor speed
1rpm
0x700E
28686