1-03
Remote Start Runtime
- This option changes the remote start run time of the vehicle from 3, 15, 25, and 45 min-
utes.
1-04
Driver’s Priority Unlock
- The driver’s door must be isolated from the other doors. Use the Orange/Black CN4 as
your 2nd Unlock output.
1-05
Reservation Lock
- Manual transmission only. Setting III will provide a 10 second delay before the vehicle shuts
off after closing the last door to allow for another door to open. Upon a door opening, the user will have 2 minutes to
close the last door in order for reservation mode to set.
1-06
Ignition Controlled Door Locks
– Setting 2 will lock the doors when the foot brake is pressed and doors closed.
Tach sensing mode must be used for setting 3. You must also turn this feature on through the remote by tapping I+IV (2
Way remotes) or Lock+Key (1 Way remotes)
1-07
Auto Relock
– This option will automatically relock/rearm after the system has been disarmed and the doors have
not been opened.
1-08
Unlock Before, Lock After Starting
– This option changes the behavior of the locking/arming and unlocking/
disarming during the remote start process. The last option setting only operates the lock output after remote starting only.
2-01
Cold Start w/thermister
– This option turns on the cold/hot starting features. This option works in conjunction
with 1-02, 2-02, and 2-03. The thermistor must be plugged into the controller/brain.
2-02
Temperature of cold starting
– Works in conjunction with Options 1-02 and 2-03. See option table for available
temperatures.
2-03
Temperature of hot starting
– Works in conjunction with Options 1-02 and 2-02. See option table for available
temperatures.
2-04
Start runtime
– Resets remote start and turbo run-time while vehicle is remote started.
2-05
Rearm / Horn / Aux1
– This option determines the behavior of the yellow wire on the 10 pin connector of the
FT820. Default the wire will act as a rearm negative pulse. Option 2 changes the wire into a horn trigger wire. Option 3
changes the wire into an Aux 1 output
2-06-A
Rearm Output
– This setting will determine when the rearm wire will pulse during use of the remote starter.
This is the default setting of this system.
2-06-B
Horn Output
- When 2-05 is set to Horn setting you can change the event that the horn wire pulses. This would
be upon double lock, lock and unlock, lock, unlock and start, and double lock and start.
2-06-C
Aux 1 Output
– This option determines the duration of the Aux 1 output. Setting IV allows the output duration
to pulse only upon remote start shutdown.
2-07
Siren Duration
– This option determines the duration of the siren during the alarm and panic triggers. The avail-
able timing is from 30, 60, 120, and chirps for 20 seconds.
2-08
Starter-Kill
– This option determines the mode of the anti-grind/starter-kill relay. You must install and connect a
starter kill relay for this feature to work correctly.
Default 1: Anti-grind + starter-kill
Option 2: Anti-grind only (no starter-kill)
Option 3: Anti-grind + passive starter-kill: starter-kill activates in 60 seconds after ignition is turned off.
o
pTIon
d
esCRIpTIons
C
onT
. fT-820
fT-820 I
nsTall
G
uIde
H
yundaI
/ K
Ia
R
emoTe
s
TaRT
and
a
laRm
www.firstechllc.com /ft820 | www.compustar.com/ft820
Copyright 2009 Firstech, LLC.