background image

 

18 

 
2-12 

Ground When Armed

 

– Ground When Armed or GWA, at default setting will send a constant 

latched negative output when armed and remote started on the blue wire on CN3. This is used to 
trigger your starter kill relay and prevent overgrinding on the vehicle's starter. The optional setting  
turns the output into a latched GWA only. Optional setting 4 will make the blue wire an Auxiliary 4 
which is programmable by your OP500 Option Programmer. 

 
2-13 

Advanced Tachless

 - 

This feature when used in conjunction with feature 2-04 option 3 will 

provide an enhanced Tachless engine sensing mode.

 

 
3-01 

Secure Aux Output

 

– On the default setting, trunk and star buttons must be held for 2.5 seconds 

before Aux 1 or Aux 2 can be triggered. This prevents accidental triggering of the outputs. Option 
setting 2 turns this feature off. 

 
3-02 

Aux 1 Output

  - This option determines the duration of the Aux 1 output. Setting 4 allows the 

output duration to be set for a specific length of time. 

 
3-03 

Aux 2 Output

  - This option determines the duration of the Aux 2 output. Setting 4 allows the 

output duration to be set for a specific length of time. 

 
3-04 

Aux 1 Output Control 

– This option sets the condition which controls Auxiliary 1 and how it is 

triggered. Please see the option table 3 for details. 

 
3-05 

Aux 2 Output Control 

- This option sets the condition which controls Auxiliary 2 and how it is 

triggered. Please see the option table 3 for details. 

 
3-06 

Auxiliary Input 1

 

– This option changes the input condition on the gray/white wire on CN3. 

 
Default 1: 

Will pre-warn with a negative (-) ground input. 

Option 2:

 Will arm the system with a negative (-) ground input. Used when adding an alarm to a factory keyless entry 

system. 

Option 3:

 Turns the wire into a closed loop trigger. Can be used to detect if the circuit is broken like for a trailer 

connected to the truck hitch. 

Option 4:

 Turns the wire into a (-) ignition input that bypasses the instant trigger wire and shock sensor. 

 

3-07 

Auxiliary Input 2

 

– This option changes the input condition on the black/white wire on CN3. 

 
Default 1:

. Will instant trigger with a negative (-) ground input. 

Option 2:

 Will disarm the alarm with a negative (-) ground input. Used when adding an alarm to a factory keyless entry 

system. 

Option 3:

 Turns the wire into a (-) Key Sense wire. If the wire sees a negative trigger it will not allow the system to arm. 

Option 4:

 Turns the wire into a (-) Parking Light Reminder input. If the wire sees a negative trigger during arm it will 

chirp the siren and flash parking lights 5 times to notify the user that their parking lights are still on. 

 

3-08 

Shock Sensor Inputs

 

– This option changes the behavior of the 1

st

 Stage or 2

nd

 Stage input 

wires. When Option 2 or 3 is set and the system is armed or disarmed and sees ground on either 
wire, the CM600-AS will not arm or disarm. 

 
4-01 

Connector 2, Pin 1

 - This option will change the behavior of the green/white wire on Connector 2 

 

(CN2). At default the wire will act as negative parking light output but can be changed to (-) 

 

accessory or ignition. 

 
4-02 

Connector 2, Pin 3

 - This option will change the behavior of the green/white wire on Connector 2 

 

(CN2). At default the wire will act as negative parking light output but can be changed to (-) 

 

accessory or ignition. 

 

Содержание CM600-AS

Страница 1: ...eceived including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to ope...

Страница 2: ...n Harness 11 Connector 3 CN3 8 Pin Harness 11 Connector 4 CN4 6 Pin Lock Harness 12 Connector 5 CN5 4 Pin RS232 Port 2 Way Data 13 Connector 6 CN6 4 Pin Antenna Cable 13 Connector 7 CN7 2 Pin Pre wire...

Страница 3: ...n Call 888 820 3690 or visit our website at www compustar com to locate your nearest dealer Caution The Manufacturer s warranty will be void if this product is installed by anyone other than an author...

Страница 4: ...arn Tach STEP 1 Start the vehicle with the key and allow it to idle down STEP 2 Press and hold the foot brake STEP 3 While holding the foot brake hold the remote start button on the remote for 2 5 sec...

Страница 5: ...each additional remote The CM600 AS can store up to three remotes Exiting Programming Programming is a timed sequence If you can not get the remote s to program then the system enters Valet Mode The...

Страница 6: ...twice to confirm the system is out of Valet Mode 2 You can put the system into Valet by holding the foot brake and then turning the ignition key on and then off five times within 7 seconds The parking...

Страница 7: ...l for 2 5 seconds The parking lights will flash once to confirm a good tach signal The parking lights will flash three times to indicate the tach did not learn Two seconds following the three flashes...

Страница 8: ...ng section of this manual for details Upon receiving confirmation that your vehicle is running the parking lights will light solid The remote start run time can be set for 3 15 25 or 45 minutes The op...

Страница 9: ...9 CM600 AS Wiring Schematic...

Страница 10: ...ry Pin 6 Yellow Starter 12V positive output This wire must be connected for remote start The proper wire will test 0V with the key in the off position 0V while the key is in the on position and 12V du...

Страница 11: ...l pulse the factory horn The proper wire will show ground while the horn is sounding Pin 8 Gray Black Instant negative trigger input This input looks for a ground input when the system is armed locked...

Страница 12: ...ng doors or power windows The settings can be changed via option 3 02 To set a custom timed output you must use option setting 4 as well as an OP500 Option Programmer Pin 8 Yellow White Auxiliary 2 Ou...

Страница 13: ...he signal from remote Pin 2 White TX output This wire transmits the signal to remote Pin 3 Red Constant 12V positive output Pin 4 Black Negative ground Connector 7 CN7 2 Pin Pre wired LED Pin 1 Black...

Страница 14: ...Only Aux 3 1 12 Dome Light Delay Off 5 Seconds 45 Seconds Auto 1 13 Trigger Start Triple Pulse Double Pulse Single Pulse Feature Default Setting I Optional Setting II Optional Setting III Optional Se...

Страница 15: ...e Prewarn 2nd Stage Instant 1st Stage Disable Arm Disarm 2nd Stage Instant 1st Stage Input Prewarn 2nd Stage Disable Arm Disarm 3 09 Sliding Door Aux 1 Aux 2 Control for iDatalink Modules Off Unlock F...

Страница 16: ...Disarm Wire This feature turn the disarm wire into a double pulse output for shutting down factory alarm outputs 1 06 IGN ACC Pulse with Disarm This option will pulse the ignition and accessory wires...

Страница 17: ...Setting 2 changes to the tach sensing where you will need to connect to a wire that tests as a tach Setting 3 changes the mode to alternator sensing it does not require a tach connection Setting 4 doe...

Страница 18: ...wire on CN3 Default 1 Will pre warn with a negative ground input Option 2 Will arm the system with a negative ground input Used when adding an alarm to a factory keyless entry system Option 3 Turns t...

Страница 19: ...nected the OP500 will power up as long as the main ignition harness to the controller has been connected properly STEP 3 To change the option number you wish to program use the left and right arrow ke...

Страница 20: ...3 Lock Key Start for 2 5 seconds then Lock Unlock for 2 5 seconds Option Menu 4 Lock Key Start for 2 5 seconds then Lock Key Start for 2 5 seconds STEP 3 Once the system confirms the option number set...

Страница 21: ...tach before 1st remote start 2 Ignition on or foot brake on 5 Foot brake on 6 Hood open 8 Remote start failure 10 System is in Valet Mode Alarm LED Diagnostics When the alarm is triggered the LED if...

Страница 22: ...is wire can be used to power up a 2nd Ignition 2nd Starter or 2nd Accessory wire on the vehicle The behavior of the wire is changed by the internal jumper in the control module How do I set the auxili...

Страница 23: ...henever I try to arm the vehicle it chirps the siren 3 times and will not arm A Check all the trigger input wires for ground Do the door locks flip flop in polarity A No You can use the DM700 relay pa...

Страница 24: ...am 5 00 pm Pacific Standard Time Email support compustar com Web techfeed compustar com Wiring Diagrams Go to www firstechonline com to access Computech3 If you are an authorized dealer and unable to...

Отзывы: