Solid fuel boiler - Maintain a constant temperature in 
heating circuit

M

M

Maintain a constant temperature of heat reservoir

UNI TEMP

UNI TEMP

UNI

TEMP

UNI TEMP

UNI TEMP

DTC100/2

M

Examples:

U

N

T

E

M

P

M

UNI

TEMP

ROTOTERM 

MR-TR

Maintain a constant temperature in 
sanitary water circuit

Floor heating - Maintain a 
constant temperature of 
heating circuit

Solar pool heating - Maintain a constant temperature of 
heating circuit

Floor heating regulation 
from radiator heating circuit

UNI TEMP 

UNI TEMP 

www.first.si

7

FIRŠT-ROTOTEHNIKA, s.p., 

Radegunda 54, 3330 Mozirje 
info@?rst.si, http://www.?rst.si

PE VELENJE: 

Koroška c. 56a, 3320 Velenje
tel: 03 / 898 35 00, fax: 03 /  898 35 35

In compliance with standards

All our products fulfil the essential safety and protection requirements for CE conformity marking according to the 
following directives

EMC dire

ctive: 2004/108/EEC

 / LV dire

ctive: 2006/95/EEC / PAH directive 2005/69/EEC.

In compliance with standards:

EN 60730-2-14

;

 1997 + A1:2001 + A11:2005 + A2:2008

EN60730-1:2000 + A12:2003 + A12:2004 + A14:2005 + A16:2007 + A2:2008
EN 55014-1:2006
EN 61000-3-2:2006
EN 61000-3-3:2006
EN 62233:2008
ZEK 01.2-08

We reserve the right to modify the instructions and the technical data of the product without prior notice.

Содержание UNI TEMP

Страница 1: ...ting kit FIR T ROTOMIX ROTOMIX G ESBE VRG VRB ACASO TERMOMIX BARBERI FEROTERM PAW EURONORM ESBE IMP DANFOSS BESSER SELTRON LOVATO TUXHORN STRAWA CIMBERIO UNI TEMP is a constant temperature controller...

Страница 2: ...ort Caution power supply voltage 24VAC It may only be installed by suitably trained personnel All applicable legal or institutional installation regulations must be complied with The device must be pr...

Страница 3: ...it Code Enclosed mounting kit 58024 VRG VRB ACASO TERMOMIX BARBERI FEROTERM PAW EURONORM ESBE IMP DANFOSS BESSER SELTRON LOVATO TUXHORN STRAWA CIMBERIO By special request 58025 SELTRON LOVATO PAW 5802...

Страница 4: ...controller calibration is carried out DIP switches and trimmer Xp are located inside controller To open the controller it is necessary to loosen the screws on the cover 3x and handle screw 1x LED ind...

Страница 5: ...Example Desired temperature 50 C Xp parameter proportional control range of valve 10K When the temperature is less than 45 controller gives continuous signal for opening mixing valve C When the temper...

Страница 6: ...UNI TEMP UNI TEMP UNI TEMP UNI TEMP DTC100 2 M Examples UNI TEMP M UNI TEMP ROTOTERM MR TR Maintain a constant temperature in sanitary water circuit Floor heating Maintain a constant temperature of he...

Страница 7: ...rements for CE conformity marking according to the following directives EMC directive 2004 108 EEC LV directive 2006 95 EEC PAH directive 2005 69 EEC In compliance with standards EN 60730 2 14 1997 A1...

Отзывы: