2
WARNING: NEVER PLUG IN UV LAMP WHEN IT IS OUTSIDE THE STAINLESS STEEL
CHAMBER. NEVER LOOK DIRECTLY AT ILLUMINATED UV LAMP
CAUTION: QUARTZ SLEEVE AND LAMP ARE EXTREMELY FRAGILE AND EASILY
DAMAGED…BE VERY CAREFUL WHEN HANDLING, INSTALLING AND REPLACING
THE SLEEVE AND LAMP. ALWAYS REPLACE THE QUARTZ SLEEVE WHEN
REPLACING THE LAMP.
1. Using mounting clips provided, mount the stainless steel chamber (Item 7) in the desired
location. It is recommended that the chamber be mounted horizontally to prevent dropping
the quartz sleeve and UV lamp during assembly. Ensure there is a minimum of 37” on one
side of the stainless steel chamber for installation and future replacement of the quartz
sleeve and UV lamp.
2. Install the flow control (12 gpm, UVPC-12 or 20 gpm, UVPC-20) on the connection that you
have designated as the inlet of the unit. The unit itself is not directional regarding flow.
3. Connect inlet (with flow control) and outlet of the stainless steel chamber to the plumbing.
4. Avoid touching the sides of the quartz sleeve and lamp. Handle only the ends. Gloves are
recommended to prevent getting oil from your hands on the quartz sleeve and UV lamp.
5. Remove aluminum nuts from
both ends
of the stainless steel chamber (Item 2).
6. Carefully insert the quartz sleeve (Item 6) into one end of the stainless steel chamber (Item
7) so that it exits the other end. Make sure equal lengths of quarts sleeve protrude from
each end.
7. Place an o-ring (item 5) on each end of the quartz sleeve where it enters the stainless steel
chamber.
8. Replace the aluminum nuts (item 2) on each end of the chamber. The nut without the plastic
end cover is for the end with the electrical cord.
The nuts should be only hand tight.
9. Carefully slide the lamp through aluminum nut on one end of the chamber.
10. Ensure the power cord is NOT plugged in and connect the lamp to the lamp socket on the
wiring harness.
11. Screw the water proof cord strain relief (Item 1) into the aluminum nut.
12. Turn on water supply and check for leaks. Repair if necessary.
13. Plug the ballast (Item 9) into GFI (ground fault interrupt) protected electrical outlet.
14. Run water through the unit for 5 minutes prior to use.
15. If your unit has a maintenance timing device, attach the timer to the chamber. Strap and
screws are provided.
Push the reset button to start the timer.
The timer indicates when
lamp and quartz sleeve replacement is required.
If the plumbing system has been previously exposed to water that is known to have
bacterial contamination, the entire plumbing system will require disinfection once the
UV light is installed and in operation.
Installation