WARNING:  NEVER PLUG IN UV LAMP WHEN IT IS OUTSIDE THE STAINLESS STEEL 
CHAMBER.  NEVER LOOK DIRECTLY AT ILLUMINATED UV LAMP  

CAUTION:    QUARTZ  SLEEVE  AND  LAMP  ARE  EXTREMELY  FRAGILE  AND  EASILY 
DAMAGED…BE VERY CAREFUL WHEN HANDLING, INSTALLING AND REPLACING 
THE  SLEEVE  AND  LAMP.    ALWAYS  REPLACE  THE  QUARTZ  SLEEVE  WHEN 
REPLACING THE LAMP. 

1.  Using mounting clips provided, mount the stainless steel chamber (Item 7) in the desired 

location.  It is recommended that the chamber be mounted horizontally to prevent dropping 
the quartz sleeve and UV lamp during assembly.  Ensure there is a minimum of 37” on one 
side of the stainless steel chamber for installation and future replacement of the quartz 
sleeve and UV lamp. 

2.  Install the flow control (12 gpm, UVPC-12  or  20 gpm, UVPC-20) on the connection that you 

have designated as the inlet of the unit.  The unit itself is not directional regarding flow. 

3.  Connect inlet (with flow control) and outlet of the stainless steel chamber to the plumbing. 
4.  Avoid touching the sides of the quartz sleeve and lamp.  Handle only the ends.  Gloves are 

recommended to prevent getting oil from your hands on the quartz sleeve and UV lamp. 

5.  Remove aluminum nuts from 

both ends

 of the stainless steel chamber (Item 2). 

6.  Carefully insert the quartz sleeve (Item 6) into one end of the stainless steel chamber (Item 

7) so that it exits the other end.  Make sure equal lengths of quarts sleeve protrude from 
each end. 

7.  Place an o-ring (item 5) on each end of the quartz sleeve where it enters the stainless steel 

chamber. 

8.  Replace the aluminum nuts (item 2) on each end of the chamber.  The nut without the plastic 

end cover is for the end with the electrical cord.  

The nuts should be only hand tight.

 

9.  Carefully slide the lamp through aluminum nut on one end of the chamber. 
10.  Ensure the power cord is NOT plugged in and connect the lamp to the lamp socket on the 

wiring harness. 

11.  Screw the water proof cord strain relief (Item 1) into the aluminum nut. 
12.  Turn on water supply and check for leaks.  Repair if necessary. 
13.  Plug the ballast (Item 9) into GFI (ground fault interrupt) protected electrical outlet. 
14.  Run water through the unit for 5 minutes prior to use. 
15.  If your unit has a maintenance timing device, attach the timer to the chamber.  Strap and 

screws are provided.  

Push the reset button to start the timer.

  The timer indicates when 

lamp and quartz sleeve replacement is required. 

 
 

If the plumbing system has been previously exposed to water that is known to have 
bacterial contamination, the entire plumbing system will require disinfection once the 
UV light is installed and in operation.

 

Installation 

Содержание UVPC-12

Страница 1: ...y 33 N Churubusco IN 46723 Phone 260 693 1972 Fax 260 693 0602 UVPC 12 and UVPC 20 Instructions 190726 docx ULTRA VIOLET LIGHT WATER STERILIZER Please read these instructions completely before installing this unit UVPC 12 and UVPC 20 ...

Страница 2: ...quartz sleeve and bulb approximately 37 5 Install only in an area that will maintain an ambient temperature between 36 F and 104 F 6 Maximum operating pressure is 100 psi 7 Connect to plumbing system while complying to all state and local regulations ITEM PART DESCRIPTION 1 UVPC PG135 Water Proof Cord Strain Relief 2 UVPC A02 Aluminum Nut 3 UVPC 4P80 Lamp Socket and Wire 4 UVPC LAMP Germicidal Lam...

Страница 3: ...ss steel chamber Item 2 6 Carefully insert the quartz sleeve Item 6 into one end of the stainless steel chamber Item 7 so that it exits the other end Make sure equal lengths of quarts sleeve protrude from each end 7 Place an o ring item 5 on each end of the quartz sleeve where it enters the stainless steel chamber 8 Replace the aluminum nuts item 2 on each end of the chamber The nut without the pl...

Страница 4: ... rings item 5 6 See installation procedure to install new quartz sleeve and lamp 7 If timing device is used press and hold button to reset timer Dimensions UVPC 12 UVPC 20 A Distance Between Inlet and Outlet 31 5 31 5 B Chamber Diameter 2 5 4 8 C Total Height 4 3 5 6 D Overall Length 37 38 Maximum Flow Rate 12 GPM 20 GPM Minimum UV Dose maximum flow rate at end of recommended bulb life 16 mJ cm 2 ...

Страница 5: ... our facility and any local labor charges Stainless Steel Chamber Aluminum Nuts Ballast Lamp Socket and Lead Wire Strain Relief Fitting GENERAL CONDITIONS Should a defect or malfunction occur contact the dealer that you purchased the product from If you are unable to contact the dealer contact First Sales LLC 260 693 1972 We will require a full description of the problem model number date of purch...

Отзывы: