1
Never plug in UV lamp when it is outside the stainless steel chamber.
1. Water may need to be treated prior to entering the sterilizer. Water must be free of color and turbidity.
Turbidity and color will shield bacteria from the UV rays. A 5 micron sediment cartridge filter is
recommended to precede the UV. Water hardness should be 5 grains per gallon or less and the iron
concentration below 0.3 ppm. Ideally, it should be soft and iron free.
2. All water treatment equipment (except reverse osmosis systems) should be installed before the
sterilizer.
3. A non-switched, 115 volt GFI protected electrical outlet is needed near the unit.
4. It is recommended that the unit be installed horizontally with adequate room on one side to remove the
quartz sleeve and bulb
(approximately 37”).
5. Install only in an area that will maintain an ambient temperature between 36°F and 104°F.
6. Maximum operating pressure is 100 psi.
7. Connect to plumbing system while complying to all state and local regulations.
ITEM #
PART #
DESCRIPTION
1
UVPC-PG135
Water Proof Cord Strain Relief
2
UVPC-A02
Aluminum Nut
3
UVPC-4P80
Lamp Socket and Wire
4
UVPC-LAMP
Germicidal Lamp, 12 gpm, 9,000 hour
UVPC-LAMP-20
Germicidal Lamp, 20 gpm, 9,000 hour
5
UVPC-OR
O-Ring
6
UVPC-QS
Quartz Sleeve
7
UVPC-ST635890
Stainless Steel Chamber, UVPC-12
UVPC-B6
Stainless Steel Chamber, UVPC-20
8
UVPC-1002
Mounting Clip for UVPC-12
UVPC-CLIP-20
Mounting Clip for UVPC-20
9
UVPC-BALL
Ballast, 115v, 12 gpm unit
UVPC-BALL-20
Ballast, 115v, 20 gpm unit
10
UVPC-GLO PLUG
UV Lamp indicator (Glow Plug)
Not
Shown
CV7A106D-12
External Flow Control, UVPC-12
CV7A106D
External Flow Control, UVPC-20
Pre-installation Instructions
Components
FIGURE 1