7
STEP 13:
Unplug the softener from the electrical outlet to keep it in the backwash position.
Refer to Figure 3 (page 6) for appropriate bypass valve operation. Rotate bypass lever of
stainless steel bypass ¼ of the way to “Service” allowing unit to fill slowly. You should
hear water trickling into the mineral tank. Filling the media tank in this position will force
any trapped air and carbon dust to the drain.
When all air has been purged from the
system and only clear water is running to the drain, slowly open the bypass valve
fully to the service position.
STEP 14:
Add enough water to the brine tank to have a level 1/2
” above the top step of the salt grid
(approx. 6 gal.).
STEP 15:
Plug the softener back into the electrical outlet.
Press
the center “ADVANCE” button briefly and the control valve will go to the brine draw
position
(“GO TO DR” will display). Once the cycle countdown timer appears verify that
the water level in the brine tank is dropping. Allow water level to drop below the top step
of the salt grid before continuing. If the water level does not drop, refer to section 8 of
Troubleshooting.
STEP 16:
Fill the brine tank with water softener salt.
STEP 17:
Advance the unit to the fast rinse cycle by pressing
the center “ADVANCE” button briefly
and allow the regeneration to complete automatically.
STEP 18:
Check for leaks and correct as necessary.
STEP 19:
Turn power or fuel supply back on to water heater.
STEP 20:
Set the current time of day on the timer (note AM and PM) (see Fig. 4, page 8).
NOTE:
The activated carbon in the mineral tank will retain air and cause the water to appear
milky when first installed.
The activated carbon will eventually lose its adsorptive capacity and cause the chlorine taste and odor to
return to the treated water. When this occurs the exhausted carbon will have to be replaced. A wet/dry
shop vacuum can used to remove the exhausted carbon from the filter tank. CAUTION: There is a layer
of gravel under the carbon. Make sure that only activated carbon is extracted. The exhausted carbon
should be replaced with 1 or 1.5 cubic foot of new activated carbon depending on the size of the unit.
The original start up and flushing procedure should be repeated with the new carbon.
Installation Instructions (cont.)
MEDIA REPLACEMENT