14
Fault Probable
Cause
Solution
Water changes color or be-
comes cloudy.
Rower is in direct
sunlight or has not had
water treatment.
Change rower location to reduce direct ex-
posure to sunlight. Add water treatment
and blue dye or change tank water as di-
rected in the water treatment section of this
manual.
Rowing stroke return is too
light.
Bungee not under
enough tension.
Open rear Perspex cover, cut bungee tie
wrap . Tighten by small increments using
the bungee tie off tab point and test tension
by allowing the rowing handle to return to
its furthest point forward while still having
some slight tension. Note light fraying of
the bungee cord is normal.
Rower rocks from side to
side when sitting on floor
Front/Rear frame level-
ers need adjusting
Adjust the front two frame levelers until sta-
bility is reached.
Excess Flex in frame during
hard rowing
Frame Tension Cable
requires tightening
Loosen retaining nut, and tighten rear of
Tension Cable into rear leg until cable is
taut. Retighten retaining nut. It is not nec-
essary to overtighten the Cable.
Computer screen illumi-
nates, but does not register
when rowing.
Loose or failed connec-
tion/Sensor gap too wide
(see erratic computer
display).
Check that the computer lead is connected
properly. If connected properly check sen-
sor gap. Contact your local service center
if this fails to address the problem.
Rowing stroke feels lumpy,
not smooth..
Dyneema Cable is
twisted .
You can untwist the Dyneema Cable by
simply pulling the rowing handle to the end
and turning the rowing handle to untwist
the cable.
Note: Light fraying is normal.
The VX-2 computer does
not illuminate after battery
installation.
Batteries installed incor-
rectly or need replacing.
Reinstall batteries in correct position and
try again. If the LCD screen fails to illumi-
nate, try rotating the batteries slightly in the
computer. If this fails, contact your local
service center.
The VX-2 computer display
is erratic while displaying
SPM and 500meter times.
Gap between sensor
and magnetic ring is too
wide.
Adjust sensor location using rear sliding
adjustment located inside rear Perspex
cover to a gap of no more than 2.5mm.
Troubleshooting Guide