Calibration of the resistance level sensor may need to be done periodically.
TO DO THIS FOLLOW THESE STEPS.
1.
Power on the console.
2.
Press and hold WORK and REST for 3+ seconds.
3.
The console will beep once and display the calibration screen.
4.
Set the Fluid Resistance to level 1 and wait a few seconds before clicking RESET.
5.
Set the Fluid Resistance to level 2 and wait a few seconds before clicking RESET.
6.
Set the Fluid Resistance to the next level and wait a few seconds before clicking RESET.
7.
Repeat #6 until all 10 levels have been done.
8.
When all levels are done the console will reboot.
9.
Check calibration by cycling through all resistance levels.
FLUID RESISTANCE LEVEL CALIBRATION PROCEDURE
10 LEVEL
VERTICAL TANKS
FDF - FLUID EXERCISE - FLUID RESISTANCE TWIN TANK SYSTEM
*The numbers below is a non realistic
example of calibration of a 10 level tank