MAINTENANCE

FAN

The fan should be inspected and cleaned annually, in conjunction with 
maintenance of the motor and bearings. It is important to keep the wheels 
clean in order to avoid imbalance and vibration. 

MOTOR

Check motor connections to ensure that they are secure and made in 
accordance with the wiring diagram.

The blower motor should be cleaned annually.

 

 WARNING:

Units with ECM motors have line voltage power applied at all times. Make 
sure power is disconnected before servicing.

FILTER

The air filter should be cleaned or replaced every 30 days or more frequently if 
severe conditions exist. Always replace the filter with the same type as 
originally furnished.

COIL

Any dust or other contaminants which accumulate on the heat transfer surfaces 
interferes with the air flow and impairs heat transfer. The coil must be kept 
clean by any of the following methods.

Cleaning with low-pressure compressed air.

Flushing or rinsing with water (a detergent is advisable for greasy surfaces).

DRAIN PIPING

The drain should always be:

Connected or piped to an acceptable disposal point sloped away from the 
unit at least 1/8-inch per foot.

Checked before summer operation.

Periodically checked during summer operation.

PREVENTATIVE 
MAINTENANCE

To achieve maximum performance and service life of each piece of equipment, 
a formal schedule of regular maintenance should be established and 
maintained.

MAINTENANCE 
UPDATES

A current copy of the Maintenance Program log can be found at 

www.firstco.com

 under “Product Information,” or click 

HERE

.

Содержание 450532L 5HBC32 LH

Страница 1: ...or local codes in any way These instructions must be left with the property owner SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire...

Страница 2: ...death When fan coil is operating some components are operating at high speeds Personal injury can result from touching these items with any object All electrical and service access panels must be sec...

Страница 3: ...tion exists prior to energizing any power sources Always review the nameplate and wiring diagram on each unit for proper voltage and control configurations This information is determined from the comp...

Страница 4: ...be tilted toward the drain nipple to ensure proper drainage NOTES A field fabricated secondary drain pan with a drain pipe routed to the outside of the building may be required in installations over a...

Страница 5: ...Disconnect all power supplies before servicing lock out tag out to prevent accidental electrical shock Note there may be multiple power sources Use copper conductors only Install all parts and panels...

Страница 6: ...s Damage can occur in the form of excessive heat build up and interference to the operation and moving parts will result 10 All piping made in the field should be installed with consideration of addit...

Страница 7: ...return air space is large enough that a negative pressure is not present however a trapped condensate line is recommended in case a negative condition should occur the unit would drain properly PIPING...

Страница 8: ...8 HBC X PHBC X RHBC X CHBC X Installation Operation and Maintenance Instructions FIGURE 1 Determination of Right Hand Left Hand References FIGURE 2 Coil Assemblies Right Hand Shown 3 2 Row 3 1 4 1 3 R...

Страница 9: ...r valves ceiling wall plenum or other accessories 3 All valves will operate at any angle with the exception of the motorized valve which must never be installed with the power head below horizontal Th...

Страница 10: ...am that is supplied with the unit Failure to do so could result in damage to components and will void all warranties Prior to starting the unit 1 Ensure supply voltage matches nameplate data 2 Ensure...

Страница 11: ...e filter with the same type as originally furnished COIL Any dust or other contaminants which accumulate on the heat transfer surfaces interferes with the air flow and impairs heat transfer The coil m...

Отзывы: