![First Choice Lincat OG8801N Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/first-choice/lincat-og8801n/lincat-og8801n_installation-operating-servicing-and-conversion-instructions_2293615008.webp)
IS 582 ECN 3851
Page 7 of 17
Inspection of the electrical supply
Start the appliance following the instructions for use. Check the heating devices are
working correctly.
Raise and lower the tank, dependant on model. Ensure that the cut out operates
when the tank is raised, and that power is restored when the tank is lowered into the
working position again.
In the event of a malfunction, this appliance is equipped with a safety thermostat that
interrupts the supply. After the cause has been identified and rectified, restart the
appliance by resetting the thermostat manually – push the red button situated under
the safety thermostat.
If necessary, please consult ‘Potential troubleshooting and solutions’ section.
Inspection of the rated thermal output
When the installation and adjustment operations are complete or after performing
maintenance, please verify the condition of the appliance and check the rated
thermal output of the appliance.
The rated thermal output is indicated in the table ‘Technical Data’.
Inspection of gas connection pressure
To measure the gas connection pressure, use a manometer with a minimum
designation of 0.2 mbar.
Remove the control panel. Remove the holding screw on the pressure connection p-
out and connect the manometer pipe.
Take the measurement during the operation of the appliance.
Remove the manometer pipe, replace the holding screw and control panel.
A and B in the figure 2 point to the valve regulator adjustment
Figure 2
Attention: If the values of the gas supply pressure are not within the limits indicated in
the Technical data section, switch off the appliance and contact your gas supply
company.