background image

This CO Alarm is intended for residential use. It is not intended for use 
in industrial applications where Occupational Safety and Health
Administration (OSHA) requirements for carbon monoxide detectors 
must be met.

CO alarms may not waken all individuals. If children or others do not readily
waken to the sound of the CO alarm, or if there are infants or family members
with mobility limitations, make sure that someone is assigned to assist them in
the event of an emergency.

CO Alarms will not work without power. This alarm requires a two (2) AA
batteries to operate.

CO Alarms for Solar or Wind Energy users and battery backup power 
systems: 
AC powered CO Alarms should only be operated with true or pure
sine wave inverters. Operating this Alarm with most battery-powered UPS
(uninterruptible power supply) products or square wave or “quasi sine wave”
inverters will damage the Alarm. If you are not sure about your inverter or
UPS type, please consult with the manufacturer to verify.

This CO Alarm will not sense carbon monoxide that does not reach the
sensor. 
This CO Alarm will only sense CO at the sensor. CO may be present 
in other areas. Doors or other obstructions may affect the rate at which CO
reaches the CO Alarm. For this reason, if bedroom doors are usually closed 
at night, we recommend you install a CO Alarm in each bedroom and in the
hallway between them.

CO Alarms may not sense CO on another level of the home. For example,
a CO Alarm on the second level, near the bedrooms, may not sense CO in the
basement. For this reason, one CO Alarm may not give adequate warning.
Complete coverage is recommended. Place CO Alarms on each level of the
home.

GENERAL LIMITATIONS OF CO ALARMS

CO Alarms may not be heard. The alarm horn loudness meets or exceeds
current UL standards of 85 dB at 10 feet (3 meters). However, if the CO Alarm
is installed outside the bedroom, it may not wake up a sound sleeper or one
who has recently used drugs or has been drinking alcoholic beverages. This is
especially true if the door is closed or only partly open. Even persons who are
awake may not hear the alarm horn if the sound is blocked by distance or
closed doors. Noise from traffic, stereo, radio, television, air conditioner, or
other appliances may also prevent alert persons from hearing the alarm horn.
This CO Alarm is not intended for people who are hearing impaired.

CO Alarms are not a substitute for a smoke alarm. Although fire is a 
source of carbon monoxide, this CO Alarm does not sense smoke or fire. This
CO Alarm senses CO that may be escaping unnoticed from malfunctioning 
furnaces, appliances, or other sources. Early warning of fire requires the 
installation of smoke alarms.

CO Alarms are not a substitute for life insurance. Though these CO Alarms
warn against increasing CO levels, BRK Brands, Inc. does not warrant or imply
in any way that they will protect lives from CO poisoning. Homeowners and
renters must still insure their lives.

CO Alarms have a limited life. Although the CO Alarm and all of its parts 
have passed many stringent tests and are designed to be as reliable as 
possible, any of these parts could fail at any time. Therefore, you must test
your CO Alarm weekly.

CO Alarms are not foolproof. Like all other electronic devices, CO Alarms
have limitations. They can only detect CO that reaches their sensors. They
may not give early warning to rising CO levels if the CO is coming from a
remote part of the home, away from the CO Alarm.

TROUBLESHOOTING GUIDE

If the Alarm...

Problem...

You should...

Horn "chirps" about once per minute.

Low battery warning.

Install two new AA batteries*.

Horn does three rapid "chirps" every minute; 
LED has 3 rapid flashes with "chirps".

MALFUNCTION SIGNAL. Device is not working
properly, and needs to be replaced.

Units under warranty should be returned to 
manufacturer for replacement. See “Limited
Warranty” for details.

The Alarms are linked but do not communicate with
each other.

Possible interference. Reference the Wireless
Operation section of this manual.

Move Alarms to different locations. Add an additional
Alarm between the unresponsive Alarms to route the
signal around obstructions.

CO Alarm goes back into alarm 4 minutes after you
Silence it.

CO levels indicate a potentially dangerous 
situation.

IF YOU ARE FEELING SYMPTOMS OF CO 
POISONING, EVACUATE your home and call 911 
or the Fire Department. Refer to "If The CO Alarm
Sounds" for details.

CO Alarm sounds frequently even though no high 
levels of CO are revealed in an investigation.

The CO Alarm may be improperly located. Refer to
“Where to Install CO Alarms” for details.

Relocate your Alarm. If frequent alarms continue, 
have home rechecked for potential CO problems. 
You may be experiencing an intermittent CO problem.

*For a list of acceptable replacement batteries, see “Regular Maintenance.”

If you have questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m. (CST)

BRK Brands, Inc., ("BRK") the maker of First Alert

®

brand products warrants

that for a period of five years from the date of purchase, this product will be
free from defects in material and workmanship. BRK, at its option, will repair
or replace this product or any component of the product found to be 
defective during the warranty period. Replacement will be made with a new or
remanufactured product or component. If the product is no longer available,
replacement may be made with a similar product of equal or greater value.
This is your exclusive warranty.

This warranty is valid for the original retail purchaser from the date of initial
retail purchase and is not transferable. Keep the original sales receipt. Proof 
of purchase is required to obtain warranty performance. BRK dealers, service
centers, or retail stores selling BRK products do not have the right to alter,
modify or any way change the terms and conditions of this warranty.

This warranty does not cover normal wear of parts or damage resulting from
any of the following: negligent use or misuse of the product, use on improper
voltage or current, use contrary to the operating instructions, disassembly,
repair or alteration by anyone other than BRK or an authorized service center.
Further, the warranty does not cover Acts of God, such as fire, flood, 
hurricanes and tornadoes or any batteries that are included with this unit.

BRK shall not be liable for any incidental or consequential damages caused 
by the breach of any express or implied warranty. Except to the extent 
prohibited by applicable law, any implied warranty of merchantability or fitness
for a particular purpose is limited in duration to the duration of the above 
warranty. Some states, provinces or jurisdictions do not allow the exclusion or
limitation of incidental or consequential damages or limitations on how long
an implied warranty lasts, so the above limitations or exclusion may not apply
to you. This warranty gives you specific legal rights, and you may also have
other rights that vary from state to state or province to province.

How to Obtain Warranty Service
Service:  
If service is required, do not return the product to your retailer. 
In order to obtain warranty service, contact the Consumer Affairs Division at 
1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through
Friday. To assist us in serving you, please have the model number and date of
purchase available when calling. For Warranty Service return to:
BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906

Battery: BRK Brands, Inc. make no warranty, express or implied, written or
oral, including that of merchantability or fitness for any particular purpose with
respect to battery.

For your records, please record:

Date Purchased: _______________Where Purchased: __________________

Date Installed: ____________/____________Month/Year

Replacement date is five years after installation:

_____________/____________Month/Year

NOTE: End of Life Signal — Once the unit reaches the end of its 
lifecycle, the MALFUNCTION SIGNAL will sound once a minute to 
indicate the need to immediately replace the Alarm.

LIMITED WARRANTY

7

Printed in Mexico   M08-0195-000   Q

03/07

First Alert

®

is a registered trademark of the First Alert Trust used under license.

ONELINK

®

is a trademark of BRK Brands, Inc.

Содержание ONELINK CO511

Страница 1: ...clusive Voice Warning with Location will tell you the preprogrammed location of the initiating unit and danger detected Programmable up to 11 locations ex basement When alarms sounds if programmed for...

Страница 2: ...need pencil drill with 3 16 5mm drill bit Phillips screwdriver hammer 1 Hold the mounting bracket against the ceiling or wall so the vertical mounting slot is aligned in the 12 o clock position and t...

Страница 3: ...the CO Alarm to the mounting bracket You can choose to use either feature independently or use them both Tools you will need Needle nose pliers Standard flathead screwdriver Both locking features use...

Страница 4: ...ton 5 If you have purchased the hardwired battery back up ONELINK Alarm you can now connect the hardwired Alarm by installing the three wire connector on the ceiling to the Alarm 6 Repeat steps 1 5 fo...

Страница 5: ...tside of the CO Alarm using your household vacuum s soft brush attachment A can of clean compressed air sold at computer or office supply stores may also be used Follow manufacturer instructions for u...

Страница 6: ...ed to alarm before there is an immediate life threat Since you cannot see or smell CO never assume it s not present An exposure to 100 ppm of CO for 20 minutes may not affect average healthy adults bu...

Страница 7: ...rms to different locations Add an additional Alarm between the unresponsive Alarms to route the signal around obstructions CO Alarm goes back into alarm 4 minutes after you Silence it CO levels indica...

Отзывы: