Page 22
English Customer Service: 1-844-FIRMAN1
Low Oil Shutdown
If the engine oil drops below a preset level, an
oil switch will stop the engine. Check oil level
with dipstick.
If oil level is between the
LOW
and
HIGH
mark on
dipstick:
1.Add oil to bring level to
HIGH
mark.
2.Restart engine and if the engine stops again
a low oil condition may still exist. DO NOT try
to restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is
corrected.
Do Not Overload Generator
Overloading a generator in excess of its rated
wattage capacity can result in damage to the
generator and to connected electrical devices.
To prolong the life of your generator and
attached devices, follow these steps to add
electrical load:
1. Start the generator with no electrical load
attached.
2. Allow the engine to run for several minutes
to stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
Overload Operation
The overload indicator light will turn on and cut
power to the receptacles after 30 seconds when
the load exceeds 3080W(approximately).
Parallel Operation
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is corrected.
If oil level is below the
LOW
mark on dipstick:
1. Disconnect any electronic devices, and then
stop the engine.
2. Reduce the total wattage of connected
electronic devices until it is within the generator’s
rated output.
3. Inspect the Air Inlet and Control Panel for any
blockage. Remove blockage if found.
4. Restart Engine.
How to Correct
If a cover is used, do not install until unit has cooled.
4. Turn the fuel valve to the “
OFF
”(
O
) position.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Flip the engine switch to“
OFF
”(
O
) position.
3.
Electric Start and Recoil Start Operations
CAUTION:
DO NOT
disconnect parallel cables while generator
is running.
The overload indicator light will turn on and cut
power to the receptacles after 2 seconds when
the load exceeds 3150W(approximately).
STOP
Any two FIRMAN inverter generator with parallel
port including two FIRMAN inverter model W03383
can be paralleled to increase the total available
electrical power to 6000 Watts. A FIRMAN Parallel
kit (not included) is required for parallel operation.
For Kit availability, call customer Service at 1-844-
347-6261 or visit: www.firmanpowerequipment.com.