Page 19
English Customer Service: 1-844-FIRMAN1
2. Check oil level and fuel.
3. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned on.
4. Turn the fuel valve to the “
ON
”(
l
) position.
5. Flip the engine switch to the "
RUN
"(
l
) position.
10. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
Starting the Generator (Remote Start)
NOTE:
YOUR REMOTE CONTROL IS ALREADY PROGRAMMED IN
FACTORY FOR YOUR CONVENIENCE. AND IT IS READY TO
START THE GENERATOR.
If the remote control is replaced, then you will
need to go through programming procedure in
"Remote Control Programming" section.
9. Push the choke button to the “
RUN
” position
.
7. Push and release the ''
START
'' button on the
remote control. The generator will turn over for
3 to 5 seconds and start.
An engine warmup delay is programmed into
the remote start cycle. After the generator is
running, there will be a delay of electrical
output for 15 seconds.
If the engine fails to start within 3 to 5 seconds,
the engine will attempt to start five additional
times. If the generator failed to start, the remote
start indicator light will flash.
If the generator fails to start after a total of six
attempts, the start button on the remote control
must be pushed again to begin another cycle of
six start attempts.
START
(Wireless
signal may not pass through some solid objects.)
6. Push the battery power restore switch for about
3 seconds and then release.