background image

Page 23

SERVICE AND STORAGE

DANGER

Any  damages  or  hazards  caused  by  using 
improper  fuel,  improperly  stored  fuel,  and/ 
or improperly formulated stabilizers, are not 
covered by manufacturer's warranty. 

Infrequent Service

If the unit is used infrequently, difficult starting 
may result. To eliminate hard starting, follow 
these instructions:
1. Run the generator at least 30 minutes every 
    month.
2. Run the generator, then close the fuel shut-off 
    valve and allow the unit to run until the engine 
    stops.
3. Move the engine switch to the "

OFF

" position.

Long Term Storage

It is important to prevent gum deposits from forming 
in essential fuel system parts such as the carburetor, 
fuel  hoses  or  tank  during  storage.  Also,  experience 
indicates  that  alcohol-blended  fuels  (called  gasohol, 
ethanol or methanol) can attract moisture, which leads 
to separation and formation of acids during storage. 
Acidic gas can damage the fuel system of an engine 
while in storage.

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

When the generator set is not being operated, or 
is being stored for more than one month, follow 
these instructions to avoid engine problems:

1-

ADD

 a properly formulated commercially 

FUEL 

STABILIZER

 to the tank if it is not already added.

2-Operate the engine for 5-10 minutes to circulate 
treated  fuel  into  fuel  lines  and  carburetor  before 

3- After engine cools down, remove all gasoline 
from the fuel tank. Use a commercially available, 
non-conductive vacuum siphon.

shutdown.

Drain fuel into approved container outdoors, 
away from open flame. Be sure engine is cool. 
Do not smoke.

4-

FUEL STARVATION:

  Start and run the generator 

until it stops  from lack of fuel. This will dry out all 
remaining  fuel  in  tank,  fuel  lines  and  carburetor.

7-Remove spark plug and pour about one teaspoon 
of engine oil through the spark plug hole, then pull 
the recoil starter several times to distribute the oil for 
lubricating  the  cylinder.  Reattach  the  spark  plug. 
Pull  recoil  slowly  until  resistance  is  felt.  This  will 
close  the  valves  so  moisture  cannot  enter  engine 
cylinder. Gently release recoil starter.

5-Allow the unit to cool entirely before cleaning 
and storage.  

6-Change oil with recommended grade oil.

8-Keep the engine switch and fuel valve on “

OFF

” 

position.
9-Cover the unit and store in a clean, dry place 
out of direct sunlight. 

NEVER USE WATER TO 

CLEAN GENERATOR.

NOTE:

We recommend always using a fuel stabilizer. 

A FUEL STABLIZER

 will minimize the formula-

tion of fuel gum deposits during storage, the 
fuel stabilizer can be added to the gasoline in 
the fuel tank, or into the gasoline in a storage 
container.

If  it  is  not  practical  to  empty  the  fuel  tank  and 
the  unit  is  to  be  stored  for  some  time,  use  a 
commercially available 

FUEL STABILIZER

 added 

to the gasoline to increase the life of the gasoline. 
Run  the  unit  for  5-10  minutes,  turn  off  the  fuel 
valve  and  allow  to  run  until  engine  stops  from 
lack of fuel (

FUEL STARVATION

).

Do not store gasoline from one season to 
another season.

Содержание W03381

Страница 1: ...level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number PORTABLE INVERTER GENERATOR MODEL...

Страница 2: ...More Info...

Страница 3: ...he Engine 17 Low Oil Shutdown 18 Do Not Overload Generator 18 Parallel Operation 18 Maintenance And Storage 19 Maintenance Schedule 19 Engine Maintenance 20 Change Engine Oil 20 Air Filter Maintenance...

Страница 4: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Страница 5: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...

Страница 6: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Страница 7: ...and and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is f...

Страница 8: ...loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or we...

Страница 9: ...or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of...

Страница 10: ...fore the enclosed product may differ slightly from the image on this page 1 1 2 Fuel Cap 3 Recoil Starter 4 Never Flat Wheel 5 Control Panel 6 Muffler Spark Arrester 7 Folding Handle 8 Maintenance Cov...

Страница 11: ...erage capacity has been exceeded by connected electrical devices or by a power surge When this occurs the green AC Power Indicator Light Item 7 will go off The engine will continue to run but the red...

Страница 12: ...onal equipment is required for parallel operation 12V DC outlet 8 3 Amp of DC current may be drawn from this receptacle Use this outlet to charge 12V automotive type batteries ONLY See 12V DC outlet B...

Страница 13: ...ambient temperature altitude engine condition and etc Maximum power decreases about 3 5 for each 1 000 feet above sea level and will also decrease about 1 for each 10 F 6 C above 60 F 16 C ambient tem...

Страница 14: ...cause engine speed to vary and help seat piston rings CAUTION The unit is equipped with a low oil shutdown If the oil level becomes lower than required the sensor will activate a warning device or sto...

Страница 15: ...l to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or w...

Страница 16: ...000Feet OPEN WARNING The part number and recommended minimum altitude for the application of the high altitude carburetor main jet is listed in the table below Grounding The National Electric Code req...

Страница 17: ...ements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hour...

Страница 18: ...s felt and then pull rapidly English Customer Service 1 844 FIRMAN1 bones fractures bruises or sprains resulting in serious injury 5 Pull the choke button to the CHOKE position Starting the Generator...

Страница 19: ...phase 60Hz electrical loads It is better to attach the item with largest load first electrical system consult your local utility company or a qualified electrician Connections must isolate generator...

Страница 20: ...ery charging cable to a battery that is installed in a vehicle disconnect the vehicle battery ground cable from the negative battery terminal Do not continue to charge a battery that becomes hot or is...

Страница 21: ...The overload indicator light will turn on when the load exceeds 3000W approximately If the load exceeds 3200W approximately the light will blink and cut power to the receptacles in 30 seconds Parallel...

Страница 22: ...r maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjected to operator...

Страница 23: ...urs Maintaining an air filter in proper condition is very important Dirt induced through improperly installed improperly serviced or inadequate elements damages and wears out engines Always keep the e...

Страница 24: ...ct with muffler area could cause burns resulting in serious injury WARNING English Customer Service 1 844 FIRMAN1 a Remove the maintenance cover b Remove the spark plug cable from the spark plug NGK B...

Страница 25: ...generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor...

Страница 26: ...e fuel tank Use a commercially available non conductive vacuum siphon shutdown Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke 4 FUEL STARVATION St...

Страница 27: ...en or closed 13 Engine has lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean...

Страница 28: ...Page 25 English Customer Service 1 844 FIRMAN1 PARTS DIAGRAM AND PARTS LIST W03381 Parts Diagram 119...

Страница 29: ...Page 26 193cc Engine Parts Diagram English Customer Service 1 844 FIRMAN1...

Страница 30: ...haust Muffler Assembly Flange Bolt M6 12 Cover Spark Arrester Spark Arrester Nut M6 Screw ST4 2 16 Cage Nut M5 Maintenance Cover Bolt M6 16 Handle Right Bolt M8 16 Washer 13 20 2 5 Bushing 13 3 19 3 2...

Страница 31: ...1 11 1 2 1 1 1 2 2 2 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 1 1 2 1 1 2 330723552 330723553 330723554 330723555 330723556 330723557 330723558 330723559 330723560 330723561 3...