background image

Add Fuel

Page 12

Fuel must meet these requirements:

Clean, fresh, unleaded gasoline.
Use regular UNLEADED gasoline with the 
generator engine with a minimum 87 octane
/ 87 AKI (91 RON).
For high altitude use, see "Operation at High 
Altitude".
Do not use gasoline with more than 10% 
alcohol such as E85 or ethanol.

Failure to follow Operator's Manual for fuel
recommendations voids warranty.

Avoid generator damage.

DO NOT use unapproved gasoline such as E85.
DO NOT mix oil in gasoline.
DO NOT modify engine to run on alternate fuels.

WARNING

Fuel and its vapors are extremely flammable 
and explosive which could cause burns, fire or 
explosion resulting in death, serious injury 
and/or property damage.

WHEN ADDING FUEL

Fill fuel tank outdoors.
        DO NOT overfill tank. Allow space for fuel 
        expansion. If the tank is overfilled, fuel 
can overflow onto a hot engine and cause fire 
or explosion. Wipe up any spilled fuel 
immediately.
If fuel spills, wait until it evaporates before 
starting engine.
Keep fuel away from sparks, open flames, 
pilot lights, heat, and other ignition sources.
Check fuel lines, tank, cap and fittings 
frequently for cracks or leaks. Replace if 
necessary.
        DO NOT light a cigarette or smoke when 
        filling the fuel tank.

1.Clean area around fuel fill cap, remove cap.
2.Slowly add unleaded fuel to fuel tank. Be 
careful not to fill above the red fuel level 
indicator . This allows adequate space for 
fuel expansion.

3.Install fuel cap and let any spilled fuel 
evaporate before starting engine or wipe up 
any spilled gasoline.

CAUTION

Slowly add unleaded gasoline to fuel tank.
Do not overfill tank.

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

Do not fill above the red fuel level indicator. 
This will allow expansion in hot weather and 
prevent overflow.

Red Fuel

 

Level Indicator

Operation

 

at

 

High

 

Altitude

At altitudes over 5,000 feet(1524 meters), a 
minimum 85 octane / 85 AKI (89 RON) gasoline 
is acceptable.
The  density  of  air  at  high  altitude  is  lower  than  at 
sea  level. Engine  power  is reduced  as  the  air mass 
and  air-fuel  ratio  decrease.  Engine  power  and 
generator  output  will  be  reduced  approximately 
3.5% for every 1000 feet of elevation above sea level. 
This  is  a  natural  trend  and  cannot  be  changed  by 

IMPORTANT

:  It  is  important  to  prevent  gum 

deposits  from  forming  in  fuel  system  parts  such 
as  the  carburetor,  fuel  hose  or  tank  during 
storage.  Alcohol-blended  fuels  (called  gasohol, 
ethanol or methanol) can attract moisture, which 
leads to separation and formation of acids during 
storage.  Acidic  gas  can  damage  the  fuel  system 
of  an  engine  while  in  storage.  To  avoid  engine 
problems,  the  fuel  system  should  be  emptied 
before  storage  of  30  days  or  longer.  See  the 
" Long Term Storage" section. Never use engine 
or  carburetor  cleaner  products  in  the  fuel  tank 
as permanent damage may occur.

Содержание W03381

Страница 1: ...level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number PORTABLE INVERTER GENERATOR MODEL...

Страница 2: ...More Info...

Страница 3: ...he Engine 17 Low Oil Shutdown 18 Do Not Overload Generator 18 Parallel Operation 18 Maintenance And Storage 19 Maintenance Schedule 19 Engine Maintenance 20 Change Engine Oil 20 Air Filter Maintenance...

Страница 4: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Страница 5: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...

Страница 6: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Страница 7: ...and and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is f...

Страница 8: ...loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or we...

Страница 9: ...or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of...

Страница 10: ...fore the enclosed product may differ slightly from the image on this page 1 1 2 Fuel Cap 3 Recoil Starter 4 Never Flat Wheel 5 Control Panel 6 Muffler Spark Arrester 7 Folding Handle 8 Maintenance Cov...

Страница 11: ...erage capacity has been exceeded by connected electrical devices or by a power surge When this occurs the green AC Power Indicator Light Item 7 will go off The engine will continue to run but the red...

Страница 12: ...onal equipment is required for parallel operation 12V DC outlet 8 3 Amp of DC current may be drawn from this receptacle Use this outlet to charge 12V automotive type batteries ONLY See 12V DC outlet B...

Страница 13: ...ambient temperature altitude engine condition and etc Maximum power decreases about 3 5 for each 1 000 feet above sea level and will also decrease about 1 for each 10 F 6 C above 60 F 16 C ambient tem...

Страница 14: ...cause engine speed to vary and help seat piston rings CAUTION The unit is equipped with a low oil shutdown If the oil level becomes lower than required the sensor will activate a warning device or sto...

Страница 15: ...l to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or w...

Страница 16: ...000Feet OPEN WARNING The part number and recommended minimum altitude for the application of the high altitude carburetor main jet is listed in the table below Grounding The National Electric Code req...

Страница 17: ...ements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hour...

Страница 18: ...s felt and then pull rapidly English Customer Service 1 844 FIRMAN1 bones fractures bruises or sprains resulting in serious injury 5 Pull the choke button to the CHOKE position Starting the Generator...

Страница 19: ...phase 60Hz electrical loads It is better to attach the item with largest load first electrical system consult your local utility company or a qualified electrician Connections must isolate generator...

Страница 20: ...ery charging cable to a battery that is installed in a vehicle disconnect the vehicle battery ground cable from the negative battery terminal Do not continue to charge a battery that becomes hot or is...

Страница 21: ...The overload indicator light will turn on when the load exceeds 3000W approximately If the load exceeds 3200W approximately the light will blink and cut power to the receptacles in 30 seconds Parallel...

Страница 22: ...r maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjected to operator...

Страница 23: ...urs Maintaining an air filter in proper condition is very important Dirt induced through improperly installed improperly serviced or inadequate elements damages and wears out engines Always keep the e...

Страница 24: ...ct with muffler area could cause burns resulting in serious injury WARNING English Customer Service 1 844 FIRMAN1 a Remove the maintenance cover b Remove the spark plug cable from the spark plug NGK B...

Страница 25: ...generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor...

Страница 26: ...e fuel tank Use a commercially available non conductive vacuum siphon shutdown Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke 4 FUEL STARVATION St...

Страница 27: ...en or closed 13 Engine has lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean...

Страница 28: ...Page 25 English Customer Service 1 844 FIRMAN1 PARTS DIAGRAM AND PARTS LIST W03381 Parts Diagram 119...

Страница 29: ...Page 26 193cc Engine Parts Diagram English Customer Service 1 844 FIRMAN1...

Страница 30: ...haust Muffler Assembly Flange Bolt M6 12 Cover Spark Arrester Spark Arrester Nut M6 Screw ST4 2 16 Cage Nut M5 Maintenance Cover Bolt M6 16 Handle Right Bolt M8 16 Washer 13 20 2 5 Bushing 13 3 19 3 2...

Страница 31: ...1 11 1 2 1 1 1 2 2 2 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 1 1 2 1 1 2 330723552 330723553 330723554 330723555 330723556 330723557 330723558 330723559 330723560 330723561 3...