Firman R-P03601 Скачать руководство пользователя страница 25

TROUBLE SHOOTING

Page 23

Problem

Cause

Correction

Engine

 

is

 

running

but

 

no

 

AC

 

output

 

is

 

available

.

1. Circuit

 

breaker

 

is

 

open

.

2. Fault

 

in

 

generator

.

3. Poor

 

connection

 

or

 

defective

 

cord

set

.

4. Connected

 

device

 

is

 

bad

.

1. Reset

 

circuit

 

breaker

.

2. Contact

 

authorized

 

service

 

facility

.

3. Check

 

and

 

repair

.

4. Connect

 

another

 

device

 

that

 

is

 

in

good

 

condition

.

Engine

 

runs

 

good

 

at

 

no

-

load

 

but

 “

bogs

 

down

” 

when

 

loads

 

are

 

connected

.

1. Short

 

circuit

 

in

 

a

 

connected

 

load

.

2. Engine

 

speed

 

is

 

too

 

slow

.

3. Generator

 

is

 

overloaded

.

4. Shorted

 

generator

 

circuit

.

1. Disconnect

 

shorted

 

electrical

 

load

.

2. Contact

 

authorized

 

service

 

facility

.

3.  See

 

Don't Overload

 

Generator

4. Contact

 

authorized

 

service

 

facility

.

Engine

 

will

 

not

 

start

starts

 

and

 

runs

 

rough

 

or

 

shuts

 

down

 

when

 

running

.

1. Engine

 

switch

 

set

 

to

 

OFF

 (

O

)

position

.

2

.

Fuel

 

shutoff

 

lever

 

is

 

in

 

OFF

 (

O

)

position

.

3. Low

 

oil

 

level

.

4. Dirty

 

air

 

cleaner

.

5. Out

 

of

 

fuel

.

6. Stale

 

fuel

.

7.

 

Spark

 

plug

 

wire

 

not

 

connected

 

to

spark

 

plug

.

8. Bad

 

spark

 

plug

.

9. Water

 

in

 

fuel

.

 

10. Flooded

.

11. Excessively

 

rich

 

fuel

 

mixture

.

12. Intake

 

valve

 

stuck

 

open

 

or

 

closed

.

13. Engine

 

has

 

lost

 

compression

.

1. Set

 

engine

 

switch

 

to

 

ON

 (

l

)

position

.

2. Move

 

fuel

 

shutoff

 

lever

 

to

 

ON

 (

l

)

position

.

3. Fill

 

crankcase

 

to

 

proper

 

level

 

or

place

 

generator

 

on

 

level

 

surface

.

4. Clean

 

or

 

replace

 

air

 

cleaner

.

5. Fill

 

fuel

 

tank

.

6. 

 

Drain

 

fuel

 

tank

 

and

 

carburetor

fill

with

 

fresh

 

fuel

.

7. Connect

 

wire

 

to

 

spark

 

plug

.

8. Replace

 

spark

 

plug

.

9.

 

Drain

 

gas

 

tank

 

and

 

carburetor

fill

with

 

fresh

 

fuel

.

10

Wait

 5 

minutes

 

and

 

re

-

crank

 

engine

.

11. Contact

 

authorized

 

service

 

facility

.

12. Contact

 

authorized

 

service

 

facility

.

13. Contact

 

authorized

 

service

 

facility

.

Engine

 

lacks

 

power

.

1. Load

 

is

 

too

 

high

.

2. Dirty

 

air

 

filter

.

1. Don't

 

Overload

 

Generator

2. Replace

 

air

 

filter

.

Engine

hunts

or

 

falters

.

1. Carburetor

 

is

 

running

 

too

 

rich

 

or

 

too lean

.

1. Contact

 

authorized

 

service

 

facility

.

14. Clogged or dirty fuel filter.

5. Clean or replace fuel filter.

14. Clean or replace fuel filter.

3. Clogged or dirty fuel filter.
4. Clogged spark arrester.

3. Clean or replace fuel filter.
4. Clean or replace spark arrester.

2. Clogged or dirty fuel filter.

2. Clean or replace fuel filter.

Engine shuts down when 
running.

1. Out of fuel.
2. Dirty air cleaner.
3. Low oil level.

1. Fill fuel tank.
2. Clean or replace air cleaner.
3. Fill crankcase to proper level or place. 
generator on level surface.

5. Clogged or dirty fuel filter.

English

             

Содержание R-P03601

Страница 1: ...ing equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage OWNER...

Страница 2: ...f Contents Connecting to a Building s Electrical English Trouble Shooting 23 Parts Diagram and Parts List 24 Generator Parts Digram 24 Engine Parts Diagram 26 Parts List 27 Service Information 28 Warr...

Страница 3: ...cts and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended...

Страница 4: ...duct downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may h...

Страница 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Страница 6: ...and and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is f...

Страница 7: ...loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or we...

Страница 8: ...n your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NO...

Страница 9: ...y Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as they are no longer required for normal operat...

Страница 10: ...l Cap 4 Choke Lever 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel Bottle Opener We are always working to improve our product...

Страница 11: ...rating NOTE 8 Outlet Cover Protect the receptacles from dust and debris 8 English A Digital display B AC voltage indicator C Frequency indicator D Hour indicator E Low oil indicator F Select button E...

Страница 12: ...otive Gasoline Recoil 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Spark Plug AN IMPOR...

Страница 13: ...casionally to allow stator windings to heat and cool Adjusting the load will also cause engine speed to vary and help seat piston rings CAUTION H DRAIN PLUG L 5 Replace oil fill cap dipstick and fully...

Страница 14: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Страница 15: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Страница 16: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Страница 17: ...ablize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until re...

Страница 18: ...um wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during break in period the first f...

Страница 19: ...below LOW mark on dipstick 1 Add oil to bring level to HIGH mark 2 Restart engine and if the engine stops again a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Author...

Страница 20: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Страница 21: ...ain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a...

Страница 22: ...ainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean wi...

Страница 23: ...rator Water can enter the generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and...

Страница 24: ...pour about one teaspoon of engine oil through the spark plug hole then pull the recoil starter several times to distribute the oil for lubricating the cylinder Reattach the spark plug Pull recoil slo...

Страница 25: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Страница 26: ...Page 24 PARTS DIAGRAM AND PARTS LIST P03601 Parts Diagram English...

Страница 27: ...Page 25 FIRMAN 208cc Engine Parts Diagram English...

Страница 28: ...ator A Isolator B Grommet Screw M5 14 Control Box Nut M3 Nut M4 Multi Meter Control Panel Engine Switch Outlet Cover L5 30R Outlet Cover TT 30R Outlet Cover 5 20R Fig Bolt M5 16 Nut M5 Nut M5 Flat Was...

Страница 29: ...5 336723586 336723587 336723588 336723589 336723590 336723591 336723592 336723593 336723594 336723595 336723596 336723597 336723598 336713532 336423500 336423501 336423502 336423503 336423504 33642350...

Страница 30: ...your name and address and a description of the defect 3 Ship to the address provided by ARC 4 Write the RMA number provided on the outside of the package What Your Warranty Does Not Cover Improper ins...

Страница 31: ...gine is Designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the fai...

Страница 32: ...old Catalytic converter Muffler gasket pulse valve 4 Air induction system including Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evapor...

Отзывы: