Altitude main jet 1

Altitude main jet 2

208cc

335717002

335717003

Altitude

3000-6000Feet

6000-8000Feet

OPEN

WARNING

Grounding

The National Electric Code requires your generator
must be properly connected to an appropriate
ground to help prevent electric shock.

Failure to properly ground the
generator can result in electric
shock.

WARNING

THERE IS A PERMANENT CONDUCTOR BETWEEN
THE GENERATOR (STATOR WINDING) AND THE
FRAME.

Use approved transfer equipment to prevent
backfeed by isolating generator from electric
utility workers.
When using generator for backup power, notify
utility company.
Use a ground fault circuit interrupter (GFCI) in
any damp or highly conductive area, such as
metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords
which are worn,frayed, bare or otherwise
damaged.
DO NOT operate generator in the rain or wet
weather.
DO NOT handle generator or electrical cords
while standing in water, while barefoot, or
while hands or feet are wet.
DO NOT allow unqualified persons or children
to operate or service generator.

Connecting to a Building's Electrical System

WARNING

Generator voltage could cause
electrical shock or burn resulting
in death or serious injury.





The

 

part

 

number

 

and

 

recommended

 

minimum

 

altitude  for

 

the

 

application

 

of

 

the

 

high

 

altitude

 

carburetor

 

main  jet

 

is

 

listed

 

in

 

the

 

table

 

below

.

main  jet

 

and

 

installation

 

instructions

 

can  be

 

obtained

 

by  contacting

 

Customer

 

Support

Installation

 

instructions  are

 

also

 

available

 

in

 

the

 

Technical

 

Bulletin

 

area

 

of

 

the FIRMAN

 

internet

 

site

.

English

             

increased

 

exhaust

 

emissions

 

can

 

also

 

result due

 

to

 

the

 

increased

 

enrichment

 

of

 

the

 

air

 

fuel

 

ratio

.

Other

 

high

 

altitude

 

issues

 

can

 

include

 

hard

 

starting

increased

 

fuel

 

consumption

 

and

 

s p a r k

 

p l u g

 

f o u l i n g

T o

 

a l l e v i a t e

 

h i g h

 

a l t i t u d e

 

i s s u e s

 

o t h e r

 

t h a n

 

t h e

 

n a t u r a l

power

 

loss

FIRMAN

 

can

 

provide

 

a  high

 

altitude

 

carburetor

 

main

 

jet

.

 The

 

alternative

 

Содержание R-P03601

Страница 1: ...ing equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage OWNER...

Страница 2: ...f Contents Connecting to a Building s Electrical English Trouble Shooting 23 Parts Diagram and Parts List 24 Generator Parts Digram 24 Engine Parts Diagram 26 Parts List 27 Service Information 28 Warr...

Страница 3: ...cts and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended...

Страница 4: ...duct downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may h...

Страница 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Страница 6: ...and and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is f...

Страница 7: ...loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or we...

Страница 8: ...n your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NO...

Страница 9: ...y Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as they are no longer required for normal operat...

Страница 10: ...l Cap 4 Choke Lever 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel Bottle Opener We are always working to improve our product...

Страница 11: ...rating NOTE 8 Outlet Cover Protect the receptacles from dust and debris 8 English A Digital display B AC voltage indicator C Frequency indicator D Hour indicator E Low oil indicator F Select button E...

Страница 12: ...otive Gasoline Recoil 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Spark Plug AN IMPOR...

Страница 13: ...casionally to allow stator windings to heat and cool Adjusting the load will also cause engine speed to vary and help seat piston rings CAUTION H DRAIN PLUG L 5 Replace oil fill cap dipstick and fully...

Страница 14: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Страница 15: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Страница 16: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Страница 17: ...ablize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until re...

Страница 18: ...um wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during break in period the first f...

Страница 19: ...below LOW mark on dipstick 1 Add oil to bring level to HIGH mark 2 Restart engine and if the engine stops again a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Author...

Страница 20: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Страница 21: ...ain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a...

Страница 22: ...ainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean wi...

Страница 23: ...rator Water can enter the generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and...

Страница 24: ...pour about one teaspoon of engine oil through the spark plug hole then pull the recoil starter several times to distribute the oil for lubricating the cylinder Reattach the spark plug Pull recoil slo...

Страница 25: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Страница 26: ...Page 24 PARTS DIAGRAM AND PARTS LIST P03601 Parts Diagram English...

Страница 27: ...Page 25 FIRMAN 208cc Engine Parts Diagram English...

Страница 28: ...ator A Isolator B Grommet Screw M5 14 Control Box Nut M3 Nut M4 Multi Meter Control Panel Engine Switch Outlet Cover L5 30R Outlet Cover TT 30R Outlet Cover 5 20R Fig Bolt M5 16 Nut M5 Nut M5 Flat Was...

Страница 29: ...5 336723586 336723587 336723588 336723589 336723590 336723591 336723592 336723593 336723594 336723595 336723596 336723597 336723598 336713532 336423500 336423501 336423502 336423503 336423504 33642350...

Страница 30: ...your name and address and a description of the defect 3 Ship to the address provided by ARC 4 Write the RMA number provided on the outside of the package What Your Warranty Does Not Cover Improper ins...

Страница 31: ...gine is Designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the fai...

Страница 32: ...old Catalytic converter Muffler gasket pulse valve 4 Air induction system including Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evapor...

Отзывы: