Firman P03613 Скачать руководство пользователя страница 21

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

Maintenance - Storage

General Recommendations

Regular maintenance will improve the performance and extend the life of the generator. See any
authorized dealer for service.
The generator's warranty does not cover items that have been subjected to operator abuse or
negligence. To receive full value from the warranty, the operator must maintain the generator as
instructed in this manual.
Some adjustments will need to be made periodically to properly maintain your generator.
All service and adjustments should be made at least once each season. Follow the requirements
in the maintenanc shedule chart above.

NOTICE

  

Once a year you should clean or replace the spark plug and replace the air filter. New

spark plug and clean air filter assure proper fuel-air mixture and help your engine run at peak 
performance and last longer.

To

 

be

 

performed

 

by

 

knowledgable

/

experienced

 

owner or by authorized service center.

*

MAINTENANCE SCHEDULE

ITEM

NOTES

Daily(Before
operation)

Initial
25 hours

Every
50 hours

Every
100 hours

(or annual)

Fittings/
Fasteners

Spark Plug

Engine Oil

Air Filter

Fuel Line

Exhaust
System

Engine

Check condition. Adjust gap
and clean. Replace if necessary.

Check oil level.

Clean, replace if necessary.

Check for leakage. Retighten or
replace gasket if necessary.

Check adjust valve clearance.

Clean combustion chamber.

Check. Replace if necessary.

Check fuel hose for cracks or other
damage. Replace if necessary.

Replace.

Check spark arrester screen.
Clean/Replace if necessary.

Every
250 hours

*

*

Fuel 

Clean fuel tank strainer. 
Replace if necessary.

20

Содержание P03613

Страница 1: ...P N 336745462 Rev 00 OPERATOR S MANUAL GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P03613 Rev Level 00...

Страница 2: ...ntains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical powe...

Страница 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Страница 4: ...may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency having jurisdict...

Страница 5: ...ing through any openings If an extension cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the ho...

Страница 6: ...ghtly from the image on this page 05 FEATURES AND CONTROLS 1 Fuel Gauge 2 5 0 Gallon 19L Capacity Fuel Tank 3 Fuel Cap 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 Bottle Ope...

Страница 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Страница 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Страница 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Страница 10: ...n electrician or authority having jurisdiction for local grounding requirements 3 CO Alert Carbon Monoxide CO Shutdown Indicator Light Indicates the engine shutdown due to carbon monoxide accumulation...

Страница 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Страница 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Страница 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Страница 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Страница 15: ...ative main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Страница 16: ...fuel cap and air cleaner are all in place 2 Move portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from th...

Страница 17: ...ectrical devices NOTICE If engine starts but fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information 7 Pull the starter cord...

Страница 18: ...ircuit breaker on control panel is in the closed on position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the...

Страница 19: ...rt below CO Alert DOES NOT replace carbon monoxide alarms Install battery powered carbon monoxide alarm s in your home Don t run generator in enclosed areas Color Description Red Yellow CO Alert fault...

Страница 20: ...44 FIRMAN1 19 OPERATION 2 Flip the engine switch to OFF O position If a cover is used do not install until unit has cooled 3 Turn the fuel valve to the OFF O position 2S Do not leave the generator unt...

Страница 21: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Страница 22: ...rolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REA...

Страница 23: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Страница 24: ...valve adjustment procedure is on www firmanpowerequipment com 0 004 0 006 in 0 10 0 15 mm Muffler and Spark Arrester WARNING Contact with muffler area could cause burns resulting in serious injury Do...

Страница 25: ...rrester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable gene...

Страница 26: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Страница 27: ...enerator on level surface 3 Clean or replace air cleaner 4 Fill fuel tank with gasoline 5 Drain fuel tank and carburetor fill with fresh gasoline 6 Connect wire to spark plug 7 Replace spark plug 8 Dr...

Страница 28: ...pe Flywheel Magneto Unleaded Automotive Gasoline 5 U S Gallons 19L 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engi...

Страница 29: ...PARTS DIAGRAM AND PART LIST P03613 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 28...

Страница 30: ...208cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 29...

Страница 31: ...nerator End Cover Flange Bolt M8 252 Flange Bolt M6 179 Ground Wire Flange Bolt M6 12 Nut M6 AVR Flange Bolt M5 16 Bolt washer Assemblies Generator End Cover Cap Flange Bolt M5 12 Terminal Block Bolt...

Страница 32: ...ing Gear crankshaft Woodruff Key Crankshaft Gear drive Gasket Crankcase Oil Dipstick Assy Cover crankcase Seal Oil Flg Bolt M8 32 Rod Connecting Clip Piston Pin Pin Piston Piston Ring Set Oil Ring The...

Страница 33: ......

Страница 34: ...English Customer Service 1 844 FIRMAN1 32 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Страница 35: ...rts for commercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to t...

Страница 36: ...t Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 West Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are...

Страница 37: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Страница 38: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Страница 39: ...P N 336745462 Rev 00 All rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM...

Отзывы: