Firman P03613 Скачать руководство пользователя страница 18

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

This portable generator has been pretested and adjusted to handle its full capacity.  The voltage is 
regulated using an automatic voltage regulator (AVR) . Readjusting the AVR will void warranty.

4. Connecting Electrical Loads

Damaged or overloaded extension cords could overheat, arc, and burn resulting death or 
serious injury.
Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as 
metal decking.
Do not touch bare wires or receptacles.

WARNING! Generator voltage could cause electrical shock or burn 
resulting in death or serious injury.

17

OPERATION

Do not use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
Do not operate generator in the rain or wet weather.
Do not run indoors to avoid wet conditions.
Do not handle generator or electrical cords while standing in water, while barefoot, or while 
hands or feet are wet.

1.Ensure circuit breaker on control panel is in the closed (on) position.
2. Start the generator with no electrical load attached.
3. Allow the engine to run for several minutes to stabilize.
4. Plug in and turn on the first item. It is best to attach the item with the largest load first.
5. Allow the engine to stabilize.
6. Plug in and turn on the next item.
7. Allow the engine to stabilize.
8. Repeat steps 5-6 for each additional item.

Surge Protection

There  is  a  remote  chance  that  voltage  fluctuations  may  impair  the  proper  functioning  of  some 
sensitive electronic equipment. Electronic devices, including computers and many programmable 
appliances may use components that are designed to operate within a narrow voltage range and 
may  be  affected  by  the  portable  generator’s  momentary  voltage  fluctuations.  While  there  is  no 
way  to  prevent  all  voltage  fluctuations,  you  can  take  steps  to  protect  your  sensitive  electronic 
equipment.  Install a plug-in surge suppressor on the receptacles feeding your sensitive equipment.  
Surge suppressors come in single or multi-outlet styles. They are designed to protect against short 
duration voltage fluctuations.

Содержание P03613

Страница 1: ...P N 336745462 Rev 00 OPERATOR S MANUAL GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P03613 Rev Level 00...

Страница 2: ...ntains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical powe...

Страница 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Страница 4: ...may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency having jurisdict...

Страница 5: ...ing through any openings If an extension cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the ho...

Страница 6: ...ghtly from the image on this page 05 FEATURES AND CONTROLS 1 Fuel Gauge 2 5 0 Gallon 19L Capacity Fuel Tank 3 Fuel Cap 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 Bottle Ope...

Страница 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Страница 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Страница 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Страница 10: ...n electrician or authority having jurisdiction for local grounding requirements 3 CO Alert Carbon Monoxide CO Shutdown Indicator Light Indicates the engine shutdown due to carbon monoxide accumulation...

Страница 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Страница 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Страница 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Страница 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Страница 15: ...ative main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Страница 16: ...fuel cap and air cleaner are all in place 2 Move portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from th...

Страница 17: ...ectrical devices NOTICE If engine starts but fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information 7 Pull the starter cord...

Страница 18: ...ircuit breaker on control panel is in the closed on position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the...

Страница 19: ...rt below CO Alert DOES NOT replace carbon monoxide alarms Install battery powered carbon monoxide alarm s in your home Don t run generator in enclosed areas Color Description Red Yellow CO Alert fault...

Страница 20: ...44 FIRMAN1 19 OPERATION 2 Flip the engine switch to OFF O position If a cover is used do not install until unit has cooled 3 Turn the fuel valve to the OFF O position 2S Do not leave the generator unt...

Страница 21: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Страница 22: ...rolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REA...

Страница 23: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Страница 24: ...valve adjustment procedure is on www firmanpowerequipment com 0 004 0 006 in 0 10 0 15 mm Muffler and Spark Arrester WARNING Contact with muffler area could cause burns resulting in serious injury Do...

Страница 25: ...rrester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable gene...

Страница 26: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Страница 27: ...enerator on level surface 3 Clean or replace air cleaner 4 Fill fuel tank with gasoline 5 Drain fuel tank and carburetor fill with fresh gasoline 6 Connect wire to spark plug 7 Replace spark plug 8 Dr...

Страница 28: ...pe Flywheel Magneto Unleaded Automotive Gasoline 5 U S Gallons 19L 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engi...

Страница 29: ...PARTS DIAGRAM AND PART LIST P03613 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 28...

Страница 30: ...208cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 29...

Страница 31: ...nerator End Cover Flange Bolt M8 252 Flange Bolt M6 179 Ground Wire Flange Bolt M6 12 Nut M6 AVR Flange Bolt M5 16 Bolt washer Assemblies Generator End Cover Cap Flange Bolt M5 12 Terminal Block Bolt...

Страница 32: ...ing Gear crankshaft Woodruff Key Crankshaft Gear drive Gasket Crankcase Oil Dipstick Assy Cover crankcase Seal Oil Flg Bolt M8 32 Rod Connecting Clip Piston Pin Pin Piston Piston Ring Set Oil Ring The...

Страница 33: ......

Страница 34: ...English Customer Service 1 844 FIRMAN1 32 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Страница 35: ...rts for commercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to t...

Страница 36: ...t Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 West Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are...

Страница 37: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Страница 38: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Страница 39: ...P N 336745462 Rev 00 All rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM...

Отзывы: