Firman P03607 Скачать руководство пользователя страница 22

Starting the Generator (Electric Start-Gasoline)

1. Before starting the generator, check for loose 

  

or missing parts and for any damage which 

  

may have occurred during shipment.

2. Check oil level and fuel(Gasoline).

4. Turn the fuel selector switch to “

GAS

” position.

3. Make sure the LPG cylinder

 

knob is fully closed

.

When starting engine, pull cord slowly until resistance 

is felt and then pull rapidly to avoid kickback.

Keep choke lever in “

START

” position for only 1

pull of the recoil starter. After first pull, move 

choke lever to the “

RUN

” position for up to the 

next  3  pulls  of  the  recoil  starter.  Too  much 

choke  leads  to  sparkplug  fouling/engine 

flooding  due  to  the  lack  of  incoming  air.  This 

will cause the engine not to start.

NOTE:

 When the fuel selector switch is turned 

to the “

GAS”

 position, the indicator light will 

become 

RED

 up to 

4 minutes

(before goes off).

Starting  the  engine  successfully  during  these 

4 minutes

 will turn the indicator light 

GREEN

.

5. Disconnect all electrical loads from the 

generator. Never start or stop the generator 

with electrical devices plugged in or turned on.

6. Move choke lever located on engine to “

START

” 

position.

7. Flip the engine switch to the "

START

"(

l

) position 

for few seconds and then release.

l

3

 

sec

.

REMINDER: 

MUST HAVE 

SOLID RED INDICATOR 

LIGHT

 TO BE ABLE TO START THE GENERATOR. 

THE GENERATOR CANNOT BE STARTED DURING 

BATTERY  POWER  SAVING  MODE

  UNLESS 

THE  FUEL  SELECTOR  SWITCH  IS  TURNED  TO 

THE  “

OFF

”  POSITION  AND  THEN  TURNED 

BACK TO THE “

GAS

”  POSITION.

See 

Indicator light

-

Battery power Saving 

Mode

 section for more information.

See 

Indicator light

-

Battery power Saving 

Mode

 section for more information.

THE FUEL SELECTOR SWITCH IS TURNED TO THE “

OFF

” 

POSITION AND THEN TURNED BACK TO THE  “

LPG

” 

POSITION.

WARNING

English                                                                                            

Page 

20

 

             

        

Support: [email protected]

Содержание P03607

Страница 1: ...rming any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number OWNER S MANUAL PORTABLE GENERATOR REMANUFACTURED MOD...

Страница 2: ...C E AL 80 EA5 L E AG D 85 0 L L E AE5 3LE40L 0 0A E AL 80 EA5 L E AE LL 0 E5 3L 80 EA5 8L DL L L E 5 3LE40L 35 0L L L 5 E AL8534EL L EE0AKL J0AL I5 3L 0L L L JL 58L 4HE J L L L L L EL I0A8 L 0 0A E AL...

Страница 3: ...ces tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment Save...

Страница 4: ...duct downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may h...

Страница 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Страница 6: ...and and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is f...

Страница 7: ...loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or we...

Страница 8: ...one in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergen...

Страница 9: ...or to usage If problems arise when assembling the generator call 1 844 347 6261 F E G H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide the ax...

Страница 10: ...l Valve 6 Air Filter 7 389cc FIRMAN OHV Engine 8 Recoil Starter 9 10 0 Flat Free Wheel 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel 13 Handle We are always working to improve our products Theref...

Страница 11: ...Maximum full load current may be drawn from this 120 240 Volt 30 Amp receptacle Ground Fault Circuit Interrupter conforms to UL 943 and NEC requirements This device protects you against hazardous elec...

Страница 12: ...stop the flow of electricity making the lamp shut off The GFCI s indicator light comes off RESET TEST TEST MONTHLY FOLLOW DIRECTIONS RESET BUTTON Receptacle Outlet LED Indicator Light TEST BUTTON Out...

Страница 13: ...FIRMAN1 Model Rated AC Voltage Phase Power Factor Voltage Regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel C...

Страница 14: ...te a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an even surf...

Страница 15: ...ill cap remove cap 2 Slowly add unleaded fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spille...

Страница 16: ...d the regulator won t cause bends or kinks in the hose Spray a soapy water solution one part liquid detergent and one part water to check all connections for leaks before attempting to use generator S...

Страница 17: ...he air fuel ratio Other high altitude issues can include hard starting increased fuel consumption and spark plug fouling To alleviate high altitude issues other than the natural power loss FIRMAN can...

Страница 18: ...a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords whic...

Страница 19: ...her Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the proper funct...

Страница 20: ...start up to permit engine and generator to stablize StartingtheGenerator RecoilStart LPG 1 Before starting the generator check for loose or missing parts and for any damage which may have occurred du...

Страница 21: ...he LPG cylinder in the path of muffler outlet 9 Move the choke lever to the RUN position 11 Allow generator to run at no load for few minutes upon each initial start up to permit engine and generator...

Страница 22: ...dicator light will become RED up to 4 minutes before goes off Starting the engine successfully during these 4 minutes will turn the indicator light GREEN 5 Disconnect all electrical loads from the gen...

Страница 23: ...G MODE UNLESS THE FUEL SELECTOR SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE LPG POSITION 9 Move the choke lever to the RUN position 4 Fully open the LPG cylinder knob 5 Turn the f...

Страница 24: ...gle phase 60Hz electrical loads It is better to attach the item with largest load first CAUTION When applying a load do not exceed the maximum wattage rating of the generator when using one or more re...

Страница 25: ...THE FUEL SELECTOR SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE GAS OR LPG POSITION Unwanted Shutdown The generator cannot be started during or after the 4 minutes of FLASHING mode...

Страница 26: ...n indication of a problem with the generator but only a problem with the flow of gas from the LPG cylinder If generator performance seems to be deteriorating at the same time that ice formation is obs...

Страница 27: ...commendations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been s...

Страница 28: ...horoughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new engine change oil af...

Страница 29: ...c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean with a wire brush before r...

Страница 30: ...ating environment DO NOT expose the unit to extreme conditions excessive dust dirt moisture or corrosive vapours DO NOT use a garden hose to clean the generator Water can enter the generator through t...

Страница 31: ...nductive vacuum siphon shutdown Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke 4 FUEL STARVATION Start and run the generator until it stops from l...

Страница 32: ...et engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner 5 Fill fuel tank 6 Drai...

Страница 33: ...PARTS DIAGRAM AND PARTS LIST P05701 PARTS DIAGRAM English Page 30 Support support arcaugusta com...

Страница 34: ...FIRMAN 389cc Engine Parts Diagram English Page 31 Support support arcaugusta com...

Страница 35: ...apor Hose Bracket Handle Flange Bolt M8 50 Pin Handle Fuel Tank Assy Grommet Fuel Tank Buffer Washer 336713544 357713529 336713546 336713547 336713549 336713548 336713540 357713530 336713551 357713531...

Страница 36: ...20 Gasket Cylinder Head Air Cleaner Holder Nut M6 Stud Intake Gskt Insulator Cover Subassembly Cylinder Head Plate Subassembly Lifter Stopper NO Part Number Description Qty 1 1 1 1 1 3 1 6 1 1 1 1 1 1...

Страница 37: ...iVi i i i Vi v i v V i i i i V v i iviV i i i L 7 i i Li i i i v i V i 7 9 7 i i U i U i v i V v L i i i v i i i i i i V i V U i Vi i v i v i i i v V V L i i U i i V V i L VV i v i v V v U V i V i i...

Страница 38: ...gine is Designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the fai...

Страница 39: ...ust manifold Catalytic converter Muffler gasket pulse valve 4 Air induction system including Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel ta...

Страница 40: ...P N 357745450 Rev 03 Firman Power Equipment Inc Peoria AZ 85381 www firmangenerators com 8716 West Ludlow Dr Suite 6...

Отзывы: