Page 09
English Customer Service: 1-844-FIRMAN1
Control Panel
1
2
4-1 Data-Minder(Multi-Meter)
– Push the
SELECT button to show the Voltage, Hertz and
running hours. If the low oil indicator is lit,
check the oil level.
3
4
5
7
120V, 30A Twist-Lock
(NEMA L5-30R)
6
Total power drawn from all receptacles must not exceed the name plate rating.
NOTE:
8
Outlet Cover -
Protect
the
receptacles from
dust and debris.
A - Digital display
B - AC voltage indicator
C - Frequency indicator
D - Hour indicator
E - Low oil indicator
F - Select button
1
2
3
4
5
6
7
8
Ground Terminal
– Consult an electrician
for local grounding regulations.
120/240V, 30A Twist-Lock
– (NEMA L14-30R)
Maximum full load current may be drawn from
this 120/240 Volt, 30 Amp receptacle.
Ground Fault Circuit Interrupter conforms to
UL 943 and NEC requirements. This device
protects you against hazardous electrical shock
that may be caused if your body becomes a
path through which electricity travels to reach
ground. This could happen when you touch an
appliance or cord that is “ live “ through faulty
mechanism, damp or worn insulation, etc.
120V, 20A Duplex GFCI (Ground Fault
Circuit Interrupter)
– (NEMA 5-20R)
This receptacle is rated so that a total of 20
Amp may be drawn regardless of whether
both halves or just one receptacle is used.
Engine Switch
– Flip the switch to the “
ON
(
l
)”
position and pull the recoil starter to start the
generator. Turn to the “
OFF
(
O
)” position to
turn off the generator.
30 Amp current may be drawn from this 120 Volt
receptacle.