Firman P01001 Скачать руководство пользователя страница 25

DANGER

Long Term Storage

It is important to prevent gum deposits from forming
in essential fuel system parts such as the carburetor,
fuel  hoses  or  tank  during  storage.  Also,  experience
indicates  that  alcohol-blended  fuels  (called  gasohol,
ethanol or methanol) can attract moisture, which leads
to separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine
while in storage.
When the generator set is not being operated, or
is being stored for more than one month, follow
these instructions to avoid engine problems:
1-

ADD

 a properly formulated commercially 

FUEL

STABILIZER

 to the tank if it is not already added.

2-Operate the engine for 5-10 minutes to circulate
treated  fuel  into  fuel  lines  and  carburetor  before

3- After engine cools down, remove all gasoline
from the fuel tank. Use a commercially available,
non-conductive vacuum siphon.

shutdown.

Drain fuel into approved container outdoors,
away from open flame. Be sure engine is cool.
Do not smoke.

4-

FUEL STARVATION:

  Start and run the generator

until it stops  from lack of fuel. This will dry out all
remaining  fuel  in  tank,  fuel  lines  and  carburetor.

7-Remove spark plug and pour about one teaspoon
of engine oil through the spark plug hole, then pull
the recoil starter several times to distribute the oil for
lubricating  the  cylinder.  Reattach  the  spark  plug.
Pull  recoil  slowly  until  resistance  is  felt.  This  will
close  the  valves  so  moisture  cannot  enter  engine
cylinder. Gently release recoil starter.

5-Allow the unit to cool entirely before cleaning
and storage.

6-Change oil with recommended grade oil.

Any  damages  or  hazards  caused  by  using
improper  fuel,  improperly  stored  fuel,  and/
or improperly formulated stabilizers, are not
covered by manufacturer's warranty.

8-Keep the engine switch and fuel valve on “OFF”
position.
9-Cover the unit and store in a clean, dry place
out of direct sunlight. 

NEVER USE WATER TO

CLEAN GENERATOR.

NOTE:

We recommend always using a fuel stabilizer.

A FUEL STABLIZER

 will minimize the formula-

tion of fuel gum deposits during storage, the
fuel stabilizer can be added to the gasoline in
the fuel tank, or into the gasoline in a storage
container.

If  it  is  not  practical  to  empty  the  fuel  tank  and
the  unit  is  to  be  stored  for  some  time,  use  a
commercially available 

FUEL STABILIZER

 added

to the gasoline to increase the life of the gasoline.
Run  the  unit  for  5-10  minutes,  turn  off  the  fuel
valve  and  allow  to  run  until  engine  stops  from
lack of fuel (

FUEL STARVATION

).

Do not store gasoline from one season to
another season.

SERVICE AND STORAGE

Infrequent Service

If the unit is used infrequently, difficult starting
may result. To eliminate hard starting, follow
these instructions:
1. Run the generator at least 30 minutes every

month.

2. Run the generator, then close the fuel shut-off

valve and allow the unit to run until the engine
stops.

3. Move the engine switch to the "OFF" position.

Содержание P01001

Страница 1: ...operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverag...

Страница 2: ...ectrical Loads 16 12V DC Outlet Battery Charger 16 Stopping the Engine 17 Low Oil Shutdown 18 Do Not Overload Generator 18 Maintenance And Storage 19 Maintenance Schedule 19 Engine Maintenance 20 Chan...

Страница 3: ...e that the procedure work method or operating technique that you choose does not render the generator unsafe DANGER WARNING CAUTION DANGER indicates a potentially hazardous situation which if not avoi...

Страница 4: ...SAFETY PRECAUTIONS WARNING POISONOUS GAS HAZARD WARNING WARNING...

Страница 5: ...ONLY use outside and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or v...

Страница 6: ...could cause burns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removi...

Страница 7: ...et weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generato...

Страница 8: ...roduct to power life support devices or life support appliances NEVER use this product to power medical devices or medical appliances Inform your electricity provider immediately if you or anyone in y...

Страница 9: ...e A B C D 1 Secure the handle to the fuel tank using the two handle bolts B M6X30 and rubber washers C 2 Use the supplied screwdriver to fasten securely DO NOT over tighten the bolts 3 Place the plug...

Страница 10: ...Therefore the enclosed product may differ slightly from the image on this page 1 Fuel Gauge 2 1 3 Gallon Capacity Fuel Tank 3 Handle 4 Fuel Cap 5 Choke Lever 6 Fuel Valve 7 Air Filter 8 80cc FIRMAN O...

Страница 11: ...cle 8 Outlet Cover Protect the receptacles from dust and debris 12V DC outlet 8 3 Amp of DC current may be drawn from the receptacle Use this outlet to charge 12V automotive type batteries ONLY See 12...

Страница 12: ...tage Phase Power Factor Voltage regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacity Fuel Tank Lubricat...

Страница 13: ...the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shif...

Страница 14: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Страница 15: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Страница 16: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Страница 17: ...blize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until res...

Страница 18: ...vehicle battery ground cable from the negative battery terminal Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in...

Страница 19: ...age DO NOT stop engine by moving choke control to START position Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the engine is not in use If the engine w...

Страница 20: ...Contact an Authorized FIRMAN Service Dealer 4 DO NOT operate engine until oil level is corrected Do Not Overload Generator Overloading a generator in excess of its rated wattage capacity can result in...

Страница 21: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Страница 22: ...aboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new e...

Страница 23: ...EEN BODY b Remove spark plug using provided wrench c Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks cor...

Страница 24: ...urface in a clean dry operating environment DO NOT expose the unit to extreme conditions excessive dust dirt moisture or corrosive vapours DO NOT use a garden hose to clean the generator Water can ent...

Страница 25: ...ull recoil slowly until resistance is felt This will close the valves so moisture cannot enter engine cylinder Gently release recoil starter 5 Allow the unit to cool entirely before cleaning and stora...

Страница 26: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Страница 27: ...PARTS DIAGRAM AND PARTS LIST P01001 Parts Diagram...

Страница 28: ...152F 80cc Engine Parts Diagram...

Страница 29: ...1 310715036 310725014 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 NO Part Number Description Qty 1 1 1 1 1 1 1 3 2 2 1 1 1 1 1 1 1 1 Bolt M4x16 Nut M4 Flat Washer 4 Lock Washer 6 Flat Washer...

Страница 30: ...2 1 2 1 1 1 1 1 1 2 2 1 1 1 1 1 6 1 1 2 2 2 1 1 1 2 1 1 1 1 1 1 1 Connecting Rod Screw M6 25 312723552 312723553 312723554 312723555 312723556 312723557 312723558 312723559 312723560 312723561 3127235...