Firman P01001 Скачать руководство пользователя страница 23

Spark Plug Maintenance

Changing the spark plug will help your engine
to start easier and run better.
(a) Remove the spark plug cap.

(d) Adjust the electrode gap to 0.7 to 0.8 mm

(0.028” to 0.031”).

(

e) Seat spark plug in position and thread by

hand to prevent cross threading.
(f)Tighten plug with provided wrench and put
the cap back on spark plug.

SPARK PLUG: LD E6RTC

NGK BPR6HS
BOSCH W26BC

CLEANING FUEL STRAINER

Clean the screen with gasoline every 50 hours.

SCREEN

BODY

(b) Remove spark plug using provided wrench.

(c)Inspect spark plug for damage and clean
with a wire brush before reinstalling

Inspect

 

Muffler

 

and

 

Spark

 

Arrester

Inspect the muffler for cracks, corrosion, or
other damage. Remove the spark arrester, if
equipped, and inspect for damage or carbon
blockage. If replacement parts are required,
make sure to use only original equipment
replacement parts.

Exhaust heat/gases could ignite combustibles,
structures or damage fuel tank causing a fire,
resulting in death or serious injury and/or
property. Contact with muffler area could cause
burns resulting in serious injury.

WARNING

A- Spark plug
B- Spark plug cap

Содержание P01001

Страница 1: ...operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverag...

Страница 2: ...ectrical Loads 16 12V DC Outlet Battery Charger 16 Stopping the Engine 17 Low Oil Shutdown 18 Do Not Overload Generator 18 Maintenance And Storage 19 Maintenance Schedule 19 Engine Maintenance 20 Chan...

Страница 3: ...e that the procedure work method or operating technique that you choose does not render the generator unsafe DANGER WARNING CAUTION DANGER indicates a potentially hazardous situation which if not avoi...

Страница 4: ...SAFETY PRECAUTIONS WARNING POISONOUS GAS HAZARD WARNING WARNING...

Страница 5: ...ONLY use outside and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or v...

Страница 6: ...could cause burns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removi...

Страница 7: ...et weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generato...

Страница 8: ...roduct to power life support devices or life support appliances NEVER use this product to power medical devices or medical appliances Inform your electricity provider immediately if you or anyone in y...

Страница 9: ...e A B C D 1 Secure the handle to the fuel tank using the two handle bolts B M6X30 and rubber washers C 2 Use the supplied screwdriver to fasten securely DO NOT over tighten the bolts 3 Place the plug...

Страница 10: ...Therefore the enclosed product may differ slightly from the image on this page 1 Fuel Gauge 2 1 3 Gallon Capacity Fuel Tank 3 Handle 4 Fuel Cap 5 Choke Lever 6 Fuel Valve 7 Air Filter 8 80cc FIRMAN O...

Страница 11: ...cle 8 Outlet Cover Protect the receptacles from dust and debris 12V DC outlet 8 3 Amp of DC current may be drawn from the receptacle Use this outlet to charge 12V automotive type batteries ONLY See 12...

Страница 12: ...tage Phase Power Factor Voltage regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacity Fuel Tank Lubricat...

Страница 13: ...the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shif...

Страница 14: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Страница 15: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Страница 16: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Страница 17: ...blize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until res...

Страница 18: ...vehicle battery ground cable from the negative battery terminal Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in...

Страница 19: ...age DO NOT stop engine by moving choke control to START position Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the engine is not in use If the engine w...

Страница 20: ...Contact an Authorized FIRMAN Service Dealer 4 DO NOT operate engine until oil level is corrected Do Not Overload Generator Overloading a generator in excess of its rated wattage capacity can result in...

Страница 21: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Страница 22: ...aboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new e...

Страница 23: ...EEN BODY b Remove spark plug using provided wrench c Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks cor...

Страница 24: ...urface in a clean dry operating environment DO NOT expose the unit to extreme conditions excessive dust dirt moisture or corrosive vapours DO NOT use a garden hose to clean the generator Water can ent...

Страница 25: ...ull recoil slowly until resistance is felt This will close the valves so moisture cannot enter engine cylinder Gently release recoil starter 5 Allow the unit to cool entirely before cleaning and stora...

Страница 26: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Страница 27: ...PARTS DIAGRAM AND PARTS LIST P01001 Parts Diagram...

Страница 28: ...152F 80cc Engine Parts Diagram...

Страница 29: ...1 310715036 310725014 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 NO Part Number Description Qty 1 1 1 1 1 1 1 3 2 2 1 1 1 1 1 1 1 1 Bolt M4x16 Nut M4 Flat Washer 4 Lock Washer 6 Flat Washer...

Страница 30: ...2 1 2 1 1 1 1 1 1 2 2 1 1 1 1 1 6 1 1 2 2 2 1 1 1 2 1 1 1 1 1 1 1 Connecting Rod Screw M6 25 312723552 312723553 312723554 312723555 312723556 312723557 312723558 312723559 312723560 312723561 3127235...

Отзывы: