Never  use  a  gas  container,  LPG  connector 
hose, LPG cylinder or any other fuel item that 
is damaged or appears damaged.

The LPG cylinder valve should be fully closed 
when the generator is not in use or is running 
with gasoline.


The regulator/hose assembly and cylinder 
valve must be inspected before each use for 
leaks or sign of damages.

Use  only  20  or  30  lb  capacity  cylinders  with 
Type  1,  right  hand  Acme  threads  with  this 
generator.  Verify  the  re-qualification  date 
on the tank has not expired. Do not use rusted 
or damaged cylinders. 

All new cylinders must be purged of air and 
moisture prior to filling. Used cylinders that 
have not been plugged or kept closed must 
also be purged. The purging process should 
be done by your propane gas supplier.

Do not connect or disconnect the LPG cylinder 
in enclosed area.

Do not install or replace the LPG cylinder near 
open flames, pilot lights, or sparking electrical 
equipment such as power tools, welders and 
grinders.

Attach  the  LPG  regulator/hose  assembly 
(included)  to  the  LPG  hose  connector  (inlet) 
on the control panel of the generator. Tighten 
the nut with 19 mm or adjustable wrench.
Remove the safety plug or cap from the 
cylinder valve.
Attach the other end of the LPG regulator/hose 
assembly to the cylinder valve. Tighten the nut
by  hand  clockwise  to  a  positive  stop.  Do  not 
use  a  wrench  to  tighten.  Use  of  wrench  may 
damage quick closing coupling nut and result 
in a hazardous condition.
Do not use tape or any type sealant to seal the 
LPG hose connections.

Always  position  the  cylinder  so  the  connection 
between the valve and the regulator won’t cause 
bends or kinks in the hose.
Spray  a  soapy  water  solution  (one  part  liquid 
detergent  and  one  part  water)  to  check  all 
connections  for  leaks  before  attempting  to 
use generator.   Slowly open the cylinder valve. 
A  leak  exists  if  bubbles  appear  or  grow  larger 
in size or number. This must be corrected before 
using  the  generator.  Contact  your  local 
Authorized  Service  Facility  for  assistance.  Do 

not attempt to make repairs yourself.
Do not check for leaks with a lighted match or flame.
Do not light or smoke cigarettes.
Check the fuel system periodically for leaks 
or signs of damages. 

LPG under pressure is highly flammable and 
can cause a fire or explosion if ignited.

CAUTION

LPG is heavier than air and can accumulate in confined 
spaces and low places in the event of a leak.
LPG has a distinctive odor to help detect 
potential leaks.

Do not allow children to tamper or play with 
the LPG cylinder.

 If you smell gas: close off the gas supply. Spray 
a soapy water solution to check all connections 
for  leaks  before  attempting  to  use  generator. 
Contact  a  qualified  technician  to  inspect  and 
repair  the  LPG  system  if  a  leak  found  before 
using the generator.

You must use the supplied regulator/hose 
assembly for safe operation.

WARNING

Device  used  for  handling  LPG  must  be  installed 
and  used  in  strict  conformance  with  NFPA  58 
(Liquefied  Petroleum  Gas  Code)  and  NFPA  54 
(National Fuel Gas) and all other codes, regulations 
and manufacturer recommendations.

If you smell gas: close off the gas supply. Make 
sure there is no leak before using the generator.


Do not check for leaks with a lighted match or 
flame.
The LPG cylinder valve should be fully closed 
when the generator is not in use or is running 
with gasoline.

Содержание H05752

Страница 1: ... and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number DUAL FUEL GENERATOR MODEL NUMBER H05752 Rev Level 00 DO NOT RETURN TO STORE CALL US FIRST CUSTOMER HOTLINE 1 844 347 6261 FOR QUESTIONS OR SERVICE INFORMATION Purchase Date ...

Страница 2: ...erator LPG 20 Connecting Electrical Loads 22 Stopping the Engine 22 Low Oil Shutdown 23 Do Not Overload Generator 24 Introduction Battery Cable Connection Connecting to a Building s Electrical Maintenance And Storage 25 Maintenance Schedule 25 Engine Maintenance 26 Change Engine Oil 26 Air Filter Maintenance 26 Spark Plug Maintenance 27 Cleaning Fuel Strainer 27 27 Generator Maintenance 28 28 Serv...

Страница 3: ...rmation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operating technique that the manufacturer does not specifically recommend you must satisfy yourself that it is safe for you and others You must also m...

Страница 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1 ...

Страница 5: ...ide and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Basement Crawl Space Living Area Attic Entry Way Porch Mudroom English Customer Service 1 844 FIRMAN1 ...

Страница 6: ...G OR DRAINING GASOLINE Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel li...

Страница 7: ...OT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank causing a fire resulting in death or serious injury and or property damage Contact with muffler area could cause burns resulting ...

Страница 8: ...e Gasoline can cause a fire or explosion if ignited Gasoline is a liquid fuel but it s vapors can ignite Gasoline is a skin irritant and needs to be cleaned up immediately if spilled on skin or clothes Gasoline has a distinctive odor this will help detect potential leaks quickly In any gasoline fire flames should not be extinguished unless by doing so the fuel supply valve can be turned OFF This i...

Страница 9: ... If the fire is extinguished and a supply of fuel is not turned off an explosion hazard greater than the fire hazard could be created Keep a fire extinguisher near the generator all the time Always keep the LPG cylinder in an upright position Do not subject LPG cylinder to excessive heat Contact with liquid contents of the cylinder will cause freeze burns to the skin An LPG cylinder not connected ...

Страница 10: ...the axle pin A through the wheel B 3 Slide the axle pin A through the mount point on the frame and flat washer D 4 Secure the wheel and axle pin with the cotter pin C 5 Repeat steps 2 4 to attach another wheel 3 Tip the generator slowly so that it rests on the wheels and support leg 4 Tighten bolt E and nut F with provide wrenches CAUTION D 2 Attach the support leg G to the generator frame with fl...

Страница 11: ... Cable Connection NOTE The generator comes equiped with the positive red cable red cable already attached 1 Verify the positive red cable is securely tightened to the positive terminal 2 Connect the negative black cable to negative terminal on the battery ...

Страница 12: ... FIRMAN OHV Engine 7 Recoil Starter 8 10 0 Flat Free Wheel 9 10 11 12 13 Oil Filler Cap LPG Hose Connector Inlet Outlet Cover Control Panel Handle 14 Hose Holder 15 LPG Hose with Regulator English Customer Service 1 844 FIRMAN1 We are always working to improve our products Therefore the enclosed product may differ slightly from the image on this page 2 ...

Страница 13: ...SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE GAS OR LPG POSITION See Indicator light Battery power Saving Mode section for more information Ground Fault Circuit Interrupter conforms to UL 943 and NEC requirements This device protects you against hazardous electrical shock that may be caused if your body becomes a path through which electricity travels to reach ground This could...

Страница 14: ...his should stop the flow of electricity making the lamp shut off The GFCI s indicator light comes off RESET TEST TEST MONTHLY FOLLOW DIRECTIONS RESET BUTTON Receptacle Outlet LED Indicator Light TEST BUTTON Outlet 5 To restore the flow of electricity press the RESET button on the front of the receptacle If the GFCI does not perform in this manner do not use the receptacle Contact a local service d...

Страница 15: ...wise Facing P T O Float Brushed Polyurethane Type Yes 7125 GASOLINE 7125 LPG FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section AN IMPORTANT MESSAGE ABOUT TEMPERATURE When operated above 77 F 25 C there may be a decrease in power Maximum wattage and current are subject to and limited by such factors as fuel BTU content ambient temperature altitude engine condition and etc Maximum power...

Страница 16: ...l activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an even surface to correct this If engine fails to start the oil level may not be sufficient to deactivate low oil level switch Make sure the sump is completely full of oil H DRAIN PLUG L 5 Replace oil fi...

Страница 17: ...nd fuel fill cap remove cap 2 Slowly add unleaded fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or wipe up any spilled gasoline English Customer Service 1 844 FIRMAN1 1 Gasoline CAUTION Slowly add unleaded gasoline to fuel tank Do not overfill tan...

Страница 18: ... cylinder so the connection between the valve and the regulator won t cause bends or kinks in the hose Spray a soapy water solution one part liquid detergent and one part water to check all connections for leaks before attempting to use generator Slowly open the cylinder valve A leak exists if bubbles appear or grow larger in size or number This must be corrected before using the generator Contact...

Страница 19: ...ratio Other high altitude issues can include hard starting increased fuel consumption and spark plug fouling To alleviate high altitude issues other than the natural power loss FIRMAN can provide a high altitude carburetor main jet The alternative The part number and recommended minimum altitude for the application of the high altitude carburetor main jet is listed in the table below main jet and ...

Страница 20: ...pany Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while han...

Страница 21: ... the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the proper functioning of sensitive electronic equipment WARNING POISONOUS GAS HAZARD Do not block generator air vents with paper or other material CAUTION Tilting can cause fuel spillage CAUTION English Cus...

Страница 22: ...run at no load for few minutes upon each initial start up to permit engine and generator to stablize StartingtheGenerator LPG 1 Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment 2 Check oil level NOTE When the fuel selector switch is turned to the GAS position the indicator light will become RED up to 4 minutes before goes off...

Страница 23: ... on engine to START position NOTE Do not place the LPG cylinder in the path of muffler outlet 9 Move the choke lever to the RUN position 11 Allow generator to run at no load for few minutes upon each initial start up to permit engine and generator to stablize 8 PULL TO PRIME Pull the starter cord 1 2 times Pull slowly until resistance if felt and then pull rapidly 10 PULL TO RUN Pull the starter c...

Страница 24: ...pping the Engine 1 Turn off and remove entire electrical loads Never start or stop the generator with electrical devices plugged in or turned on Let the generator run at no load for two minutes to stabilize internal temperatures of the engine and generator When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback Keep choke lever in START position for o...

Страница 25: ...h an electronic module which consumes battery power When the fuel selector switch is turned to the GAS or LPG position the indicator light will become RED up to 4 minutes before goes off Indicator light Battery Power Saving Mode Starting the engine unsuccessfully or not attempting to start the engine at all during these 4 minutes will switch generator to Battery Power Saving Mode in order to conse...

Страница 26: ...ional item Observing frost on LPG and regulators is common during operation and normally is not an indication of a problem As LPG vaporizes and travels from the tank to the generator engine it expands The amount of frost that forms can be affected by the size of the cylinder the amount of fuel being used the humidity of the air and other operating conditions In unusual situations this frost may ev...

Страница 27: ...chart above Notice Once a year you should clean or replace the spark plug and replace the air filter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run better and last longer ITEM NOTES Daily Before operation Initial 25 hours Every 50 hours Every 100 hours or annual Fittings Fasteners Spark Plug Engine Oil Air Filter Fuel Line Exhaust System Engine Check c...

Страница 28: ...to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new engine change oil after 25 hours DRAIN PLUG Please use a container to dump the used oil for protecting the environment b Reinstall the drain plug and fill the engine wi...

Страница 29: ...l tank causing a fire resulting in death or serious injury and or property Contact with muffler area could cause burns resulting in serious injury WARNING A B A Spark plug B Spark plug cap c DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead Replacement parts must be the sam...

Страница 30: ...ter screen Flange Screw Battery Replacement English Customer Service 1 844 FIRMAN1 1 Disconnect the negative black cable to negative terminal on the battery and disconnect the positive red cable to positive terminal on the battery 3 Remove the battery and recycle and dispose of properly 4 Install the new battery with following specification 12V sealed lead acid 2 5AH LXWXH 80X70X105mm 3 15X2 75X4 ...

Страница 31: ...til it stops from lack of gasoline This will dry out all remaining gasoline in tank fuel lines and carburetor 5 Turn fuel selector switch to OFF position Fully close the LPG cylinder knob if it is open and disconnect LPG cylinder from the generator 6 Allow the unit to cool entirely before cleaning and storage 7 Change oil with recommended grade oil 8 Remove spark plug and pour about one teaspoon o...

Страница 32: ...ttery charging circuit The battery will receive charging voltage when the engine is running The battery will maintain a proper charge if the unit is used on a regular basis about once every two weeks If it is used less frequently the battery should be connected to a trickle charger not included or battery maintainer not included to keep the battery properly charged If the battery voltage is extrem...

Страница 33: ...in fuel tank and carburetor fill with fresh gasoline 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility 12 Contact authorized service facility 13 Contact authorized service facility Engine lacks power 1 Load is too high 2 Dirty air filter 1 Don t Overload Generator 2...

Страница 34: ...Page 32 PARTS DIAGRAM AND PART LIST H05752 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 131 132 ...

Страница 35: ...Page 33 439cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 ...

Страница 36: ...er Pin 1 1 5 1 1 1 1 1 1 1 1 1 2 1 2 1 1 3 4 8 4 2 2 2 1 1 5 4 1 19 1 2 1 1 1 2 2 2 1 1 1 4 1 1 4 4 4 1 2 1 1 1 1 1 7 1 1 1 1 1 1 1 1 2 2 2 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 NO Part Number Description Qt...

Страница 37: ...alve Spring Valve Bolt Rocker Arm Oil Seal Valve Retainer Valve Guide Plate Push Rod Cylinder Head Valve In take Valve Exhaust Push Rod Lifter Valve Locating Pins Gasket cyl head Air Cleaner Holder Nut M6 Air Intake Stud Bolt Gskt Insulator Insulator Carburetor Gskt Carburetor NO Part Number Description Qty 380723515 357723554 357723555 336723555 357723556 357723557 380723516 357723559 357723560 3...

Страница 38: ...d by this warranty Normal Wear Your product needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole English Customer Service 1 844 FIRMAN1 SERVICE INFORMATION CONTACT THE FIRMAN PRODUCT SERVICE DEPARTMENT AT 1 844 347 6261 or at www firmanpowerequipment com to obtain warranty service informati...

Страница 39: ...of God and other force majeure events beyond the manufacturer s control problems caused by parts that are not original FIRMAN parts units used for prime power in place of existing utility power where utility is present or in place of utility power where utility power service does not normally exist Contact Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Servi...

Страница 40: ... failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on your small off road engine and engine powered equipment is defective the part will be repaired or replaced by FIRMAN small off road engine and engine powered equipment The California Air Resources Boa...

Страница 41: ...old Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FIRMAN POWER EQUIPMENT INC Email support firmanpowerequipment com www firmanpowerequipment com 8 Throughout the emissions warranty period defined in Subsection b 2 FIRMAN will maintain a supply of warr...

Страница 42: ...P N 357745482 Rev 05 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6 ...

Отзывы: