WARNING 

 

 
 
When this equipment is fitted to an appliance due regard must also be given to the requirements of that appliance. 
 

Before attempting to install, commission or operate this equipment all relevant sections of this document must be read and 
fully understood.  If in doubt about any requirements consult Fireye. 
 
Installation, commissioning or adjustment of this product MUST be carried out by suitably trained engineers or personnel 
qualified by training and experience. 
 
After installation or modifications to the installation all functions of the equipment MUST be checked to ensure safe and 
reliable operation of the control. 

 
The manufacturer of this equipment accepts no liability for any consequences resulting from inappropriate, negligent or incorrect 
installation, commissioning or adjustment of operating parameters of the equipment. Control panels 

must not

 be left uncovered 

while power is on.  If it is essential to do so while rectifying faults only personnel qualified by training and experience should be 
involved. The time any covers are off must be kept to a minimum and warning notices 

must

 be posted. 

 
Before attempting any work on this equipment or any equipment controlled by or connected to this equipment, all related electrical 
supplies

 must

 be isolated. 

 
Safety interlocks 

must not

 be removed or over-ridden.  Any faults once detected 

must

 be corrected before the control is operated. 

 
 
CAUTION –  SOME VERSIONS OF THIS EQUIPMENT CONTAIN A LITHIUM BATTERY  

IN THE DISPLAY UNIT 

 

Safety information

 

WARNING

Failure to observe a WARNING about the equipment described in
this manual can cause property damage, severe injury, or death.

CAUTION

Failure to observe a CAUTION may cause minor injury or damage to
equipment.

The  manufacturer  of  this  equipment  has  a  policy  of  continual  product  improvement  and  reserves  the  right  to  change  the 
specification of the equipment and the contents of this manual without notice. 

Содержание Plant Master

Страница 1: ...sequencing of up to 10 boilers When used as a sequencing master the operator can select the lead boiler limit the modulation of any boiler as well as remove a boiler from the sequence There are also...

Страница 2: ...st not be left uncovered while power is on If it is essential to do so while rectifying faults only personnel qualified by training and experience should be involved The time any covers are off must b...

Страница 3: ...mensions and mounting hole options 6 4 HOW TO INSTALL AND WIRE THE PLANT MASTER 7 4 1 Mechanical Mounting 7 4 2 Wiring Requirements 7 5 SETTING UP THE PLANT MASTER 11 5 1 Entering Plant Master Mode 12...

Страница 4: ...ll control and sequence up to 10 burner controllers for Steam Plant applications The communications are delivered via Ethernet therefore all controllers will need a display which supports Ethernet 1 2...

Страница 5: ...boil ers instead All boilers must therefore have Ethernet capable display modules NX6330 or touch screens NXTSD 104 The normal Overview button on the screen is then used to view an overview of all co...

Страница 6: ...h boiler these are entered as Horse Power HP It is important that the units used are consistent as they are used to compare the output of each boiler and it s turn down With this information along wit...

Страница 7: ...ch screen Protection Category IP65 screen bezel to panel IP20 electronics behind panel Mounting Attitude Any Number of Relays 4 Relay Type Volt free single pole change over Maximum Relay Current 6 A 2...

Страница 8: ...6 3 1 Plant Master dimensions NXTSD104...

Страница 9: ...unting Mount the Touch screen on the front of the burner cabinet or similar location If possible avoid reflections from windows or boiler house lighting when planning the location of the screen The ma...

Страница 10: ...t practice Bootlace ferrules All cabling that operates at more than 50 V must be multi strand single core PVC insulated 16 0 2 mm 0 5mm2 and must meet the requirements of IEC 227 or IEC 225 For cables...

Страница 11: ...m2 or greater as permitted by conduit sizing 4 2 3 ELV signal cable Screen Connection CANbus ELV low voltage signal cables MUST have a screen of the tinned copper braid shield type The manufacturers o...

Страница 12: ...7 Touch screen Unit Relay output 3 common 0 250 V PR8 Touch screen Unit Relay output 3 normally closed 0 250 V PR9 Touch screen Unit Relay output 3 normally open 0 250 V PR10 Touch screen Unit Relay o...

Страница 13: ...d the TSD104 will need to be temporarily connected to a powered Nexus PPC6000 or NX6100 for configuration as the Plant Master TSD No other connections to the PM TSD are permitted at this time Wiring s...

Страница 14: ...es DHCP leave the Ethernet settings for all devices to automatic DHCP If the devices are connected by a simple Ethernet switch or a hub then IP addresses for each device will have to be set manually F...

Страница 15: ...Sequencing Set Up Screen Entering the Settings screen Press the Settings button Then enter passcode 903 here 13...

Страница 16: ...ally Should the sequencing system fail the boilers will fall back to independent running using SP1 SP2 option parameters 22 x define the banking cut in and cut out limits of the lag boilers When the P...

Страница 17: ...ting The system will try to keep all boilers apart from the last lag boiler as close to this fire rate as possible Typically boiler efficiency peaks at around 75 modulation but all boilers are differe...

Страница 18: ...ted to just over the maximum available power from all currently firing boilers at high fire This is to prevent integral wind up of the PID when waiting for boilers for come on 5 2 6 On Off Strategy Th...

Страница 19: ...up to compensate Restore Procedure To restore NXTSD104 back to 6000 controller mode Press on unit button top right hand corner of NXTSD104 Select Ethernet Select Ethernet Button to Disable Plant Mast...

Страница 20: ...und defective in material or workmanship or which otherwise fails to conform to the description of the product on the face of its sales order THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES AND FIREY...