Firex FADC Скачать руководство пользователя страница 8

FALSE ALARM CONTROL

Model FADC features a False Alarm Control that, when activated,
quiets unwanted alarms for up to 15 minutes.

To use the False Alarm Control:

Press and release the test button during an unwanted alarm.
The alarm should stop within ten seconds. The RED LED will blink
once every 10 seconds. This means the smoke alarm is in False
Alarm Control. For Item 4718, the initiating alarm RED LED in an
interconnected system will continue to blink until reset by pressing
the test button.

When there are multiple units interconnected, each alarm that is
sensing smoke must have its test button depressed in order to
silence the remaining alarms.

If the smoke alarm(s) does not go into False Alarm Control and
continues to sound its loud alarm horn, or if it initially goes into False
Alarm Control™ then resounds the alarm, the smoke is too heavy
and could be a dangerous situation — take emergency action.

TESTING THE

SMOKE ALARM

W

A

R

N

I

N

G

Test each smoke alarm to be sure it is installed correctly and
operating properly.

Test all smoke alarms in an interconnected system after installation.

The Push-to-Test button accurately tests all functions. DO NOT
use an open flame to test this smoke alarm. You may ignite and
damage the smoke alarm or your home.

Test smoke alarms weekly and upon returning from vacation or
when no one has been in the household for several days.

FIELD TESTING IMPORTANT NOTICE:

When testing is required in the field by local inspectors or other par-
ties, it should be done using only the Smoke Detector Sensitivity
Analyzer model #501-1 manufactured by Gemini Scientific
Corporation. Follow the Gemini test and set-up instructions provid-
ed by the manufacturer, and use the obscuration limits provided on
the back of the smoke alarm. Refer to the smoke alarm’s instruc-
tion manual for maintenance and push-to-test operation.

Go / No-Go Testing

A functional Go / No-Go test can be performed on the unit by using
Smoke Detector Teste model #25S, manufactured for
Home Safeguard Industries, Inc. Follow the instructions included on
the tester.

Test all smoke alarms weekly by doing the following:

1. Observe the green LED. A constant green light indicates the

smoke alarm is receiving 120V AC power.

2. Firmly depress the Push-to-Test button for at least five (5) 

seconds. On Item 4718, the smoke alarm will sound 2 short,
reduced-volume beeps, and then 1 short loud beep, followed by
a pause, then repeats. All other items will sound 3 short loud
beeps followed by a 2-second pause and then repeats. The
alarm may sound for up to 10 seconds after releasing the
Push-to-Test button.

!

8

110-1082B  12/12/06  4:01 PM  Page 8

Содержание FADC

Страница 1: ...e previous alarm sound which continually beeped Test button checks smoke alarm operation and activates False Alarm Control feature which quiets unwanted alarms for up to 15 minutes Item 4718 features a latching LED which blinks the initiating alarm s red LED 3 times each minute until manually reset Item 4718 has a ramp up test horn feature which emits 2 reduced volume beeps before reaching the ful...

Страница 2: ...on every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed Interconnected ...

Страница 3: ... in each sleeping room Chapter 2 also reads as follows 2 2 2 1 In new construction where more than one smoke detector is required by 2 2 1 they shall be so arranged that operation of any smoke detector shall cause the alarm in all smoke detectors within the dwelling to sound The NFPA 1993 Edition Appendix A further states The required number of smoke detectors may not provide reliable early warnin...

Страница 4: ... Story Home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleep ing area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end If there is a basement Install a smoke alarm on the basement ceiling at the bottom of the stairwell Typical Two Story or Split Level Home Install a smoke alarm on the ceiling or wal...

Страница 5: ... highest point measured horizontally Install a smoke alarm in lived in attics or attics which house electri cal equipment like furnaces air conditioners or heaters DO NOT install smoke alarm Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarms with unwanted alarm control for these areas In areas with high humidity l...

Страница 6: ... plate To later engage tamper resist feature twist out and set aside one of the pins molded into the plate Both pins are exactly the same 2 Align recessed slots on plate with mounting holes of a 4 inch octa gon or single gang junction box 3 Gently pull household wires through center hole of plate 4 Secure plate to junction box using mounting screws 5 With a small wire connector connect white wire ...

Страница 7: ...re the neutral wire is common to both phases LED INDICATOR S Model FADC features one combined LED indicator The following section explains what condition the LED indicator is describing Constant GREEN on AC power is present GREEN is off AC power is NOT present RED blinks once a minute testing for presence of good battery RED blinks once a second smoke alarm senses smoke and simultaneously sounds a...

Страница 8: ... ignite and damage the smoke alarm or your home Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days FIELD TESTING IMPORTANT NOTICE When testing is required in the field by local inspectors or other par ties it should be done using only the Smoke Detector Sensitivity Analyzer model 501 1 manufactured by Gemini Scientific Corporation Fo...

Страница 9: ...ute even though the smoke alarm is receiving AC power On item 4718 the red LED will also blink 4 times every minute after each low battery chirp Use only the following batteries as replacements in this smoke alarm Eveready 522 or 1222 Duracell MN 1604 or Ultralife U9VL J WARNING DO NOT USE ANY OTHER TYPE OF BATTERY EXCEPT AS SPECIFIED IN THIS MANUAL DO NOT USE RECHARGEABLE BATTERIES 1 Turn off pow...

Страница 10: ...moke alarm and explain what the sound means Determine TWO exits from each room and an escape route to the outside from each exit Teach all household members to touch the door and use an alternate exit if the door is hot INSTRUCT THEM NOT TO OPEN THE DOOR IF THE DOOR IS HOT Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases Determine a safe meeting place ...

Страница 11: ... only Be sure red LED is extinguished after replacing battery Smoke alarm sounds 1 Hire an electrician to unwanted alarms inter move smoke alarm to mittently or when a new location See residents are cooking SMOKE ALARM taking showers etc PLACEMENT 2 Clean smoke alarm See Cleaning in the MAINTENANCE AND CLEANING section Interconnected smoke 1 Press and hold test alarms do not sound when button for ...

Страница 12: ...ntrols Americas smoke alarm provided that it is returned with postage prepaid and with proof of purchase date to Invensys Controls Americas This warranty does not cover damage resulting from acci dent misuse or abuse or lack of reasonable care of the product This warranty is in lieu of all other express warranties obligations or liabilities THE IMPLIED WARRANTIESOFMERCHANTABILITYANDFITNESSFORAPART...

Отзывы: