Firex FADC Скачать руководство пользователя страница 4

FOR BEST PROTECTION, WE 

RECOMMEND THAT YOU INSTALL A SMOKE

ALARM IN EVERY ROOM.

In addition, we recommend that all smoke alarms be interconnected.

Typical Efficiency 
Home (Apartment)

• 

Install a smoke alarm on
the ceiling or wall closest
to the sleeping area.

Typical Mobile Home

NOTE: 

For mobile homes built before 1978, install smoke alarms on 
an inside wall between 4 and 12 inches from the ceiling. (Older
mobile homes have little or no insulation in the ceiling.) This is
especially important if the ceiling is unusually hot or cold.

Install a smoke alarm inside each bedroom and in the hallway
outside each separate sleeping area.

Typical Single-Story Home 

Install a smoke alarm on the
ceiling or wall inside each
bedroom and in the hallway
outside each separate sleep-
ing area. If a bedroom area
hallway is more than 30 feet
long, install a smoke alarm
at each end.

If there is a basement:

Install a smoke alarm on the basement ceiling at the bottom of
the stairwell.

Typical Two-Story or Split Level Home

Install a smoke alarm on
the ceiling or wall inside
each bedroom and in the
hallway outside each sepa-
rate sleeping area. If a bed-
room area hallway is more
than 30 feet long, install a
smoke alarm at each end.

Install a smoke alarm at the
top of a first-to-second floor
stairwell.

If there is a basement:

Install a smoke alarm on
the basement ceiling at the
bottom of the stairwell.

MOBILE
HOME

Key

• Smoke Alarm

Smoke Alarm with False Alarm Control

4

110-1082B  12/12/06  4:01 PM  Page 4

Содержание FADC

Страница 1: ...e previous alarm sound which continually beeped Test button checks smoke alarm operation and activates False Alarm Control feature which quiets unwanted alarms for up to 15 minutes Item 4718 features a latching LED which blinks the initiating alarm s red LED 3 times each minute until manually reset Item 4718 has a ramp up test horn feature which emits 2 reduced volume beeps before reaching the ful...

Страница 2: ...on every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed Interconnected ...

Страница 3: ... in each sleeping room Chapter 2 also reads as follows 2 2 2 1 In new construction where more than one smoke detector is required by 2 2 1 they shall be so arranged that operation of any smoke detector shall cause the alarm in all smoke detectors within the dwelling to sound The NFPA 1993 Edition Appendix A further states The required number of smoke detectors may not provide reliable early warnin...

Страница 4: ... Story Home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleep ing area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end If there is a basement Install a smoke alarm on the basement ceiling at the bottom of the stairwell Typical Two Story or Split Level Home Install a smoke alarm on the ceiling or wal...

Страница 5: ... highest point measured horizontally Install a smoke alarm in lived in attics or attics which house electri cal equipment like furnaces air conditioners or heaters DO NOT install smoke alarm Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarms with unwanted alarm control for these areas In areas with high humidity l...

Страница 6: ... plate To later engage tamper resist feature twist out and set aside one of the pins molded into the plate Both pins are exactly the same 2 Align recessed slots on plate with mounting holes of a 4 inch octa gon or single gang junction box 3 Gently pull household wires through center hole of plate 4 Secure plate to junction box using mounting screws 5 With a small wire connector connect white wire ...

Страница 7: ...re the neutral wire is common to both phases LED INDICATOR S Model FADC features one combined LED indicator The following section explains what condition the LED indicator is describing Constant GREEN on AC power is present GREEN is off AC power is NOT present RED blinks once a minute testing for presence of good battery RED blinks once a second smoke alarm senses smoke and simultaneously sounds a...

Страница 8: ... ignite and damage the smoke alarm or your home Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days FIELD TESTING IMPORTANT NOTICE When testing is required in the field by local inspectors or other par ties it should be done using only the Smoke Detector Sensitivity Analyzer model 501 1 manufactured by Gemini Scientific Corporation Fo...

Страница 9: ...ute even though the smoke alarm is receiving AC power On item 4718 the red LED will also blink 4 times every minute after each low battery chirp Use only the following batteries as replacements in this smoke alarm Eveready 522 or 1222 Duracell MN 1604 or Ultralife U9VL J WARNING DO NOT USE ANY OTHER TYPE OF BATTERY EXCEPT AS SPECIFIED IN THIS MANUAL DO NOT USE RECHARGEABLE BATTERIES 1 Turn off pow...

Страница 10: ...moke alarm and explain what the sound means Determine TWO exits from each room and an escape route to the outside from each exit Teach all household members to touch the door and use an alternate exit if the door is hot INSTRUCT THEM NOT TO OPEN THE DOOR IF THE DOOR IS HOT Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases Determine a safe meeting place ...

Страница 11: ... only Be sure red LED is extinguished after replacing battery Smoke alarm sounds 1 Hire an electrician to unwanted alarms inter move smoke alarm to mittently or when a new location See residents are cooking SMOKE ALARM taking showers etc PLACEMENT 2 Clean smoke alarm See Cleaning in the MAINTENANCE AND CLEANING section Interconnected smoke 1 Press and hold test alarms do not sound when button for ...

Страница 12: ...ntrols Americas smoke alarm provided that it is returned with postage prepaid and with proof of purchase date to Invensys Controls Americas This warranty does not cover damage resulting from acci dent misuse or abuse or lack of reasonable care of the product This warranty is in lieu of all other express warranties obligations or liabilities THE IMPLIED WARRANTIESOFMERCHANTABILITYANDFITNESSFORAPART...

Отзывы: